title: "Building Envelope Glossary: U-Factor, SHGC, R-Value"
url: https://ela-ecolandscapingassn.org/glossary/
description: "Definitions of U-Factor, SHGC, Air Leakage, IRC R310 Egress, 16 CFR 460 R-Value Rule, Vapor Retarders, QMID, and vinyl tolerances cited to official U.S."
---

Technical Envelope Glossary 16 verified terms across fenestration, insulation, siding, gutters, and 2026 rebate policy.

# Building Envelope Technical Glossary (NFRC, FTC, EPA & IRC)

This technical exterior envelope glossary defines 16 essential performance terms, installation measurements, and regulatory rules used across residential construction. Every definition links directly to its governing federal agency, test standard, or statutory code section—including EPA ENERGY STAR Version 7.0, FTC 16 CFR Part 460, IRS Section 25C cutoff dates, and IRC Sections R310, R316.4, R702.7, and R703.

- **Technical Terms Defined** : 16 entries

- **Window Air Cap** : <= 0.3 cfm/ft2

- **Insulation Law** : FTC 16 CFR 460

- **Bedroom Egress Min** : 5.7 sq ft

## Which building envelope terms and code thresholds govern upgrades?

Filter technical terminology by building envelope category or inspect all definitions paired with direct statutory citations below.

-
-
-
-
-
-
-

Showing 16 of 16 entries

| Term | Category | Definition & Threshold |
|---|---|---|
| **U-Factor** | Windows & NFRC | Rate of non-solar heat transfer through a fenestration assembly (Btu/h·ft²·°F). Lower U-Factor indicates better insulating resistance; ENERGY STAR v7.0 Northern windows require <= 0.22. |
| **Solar Heat Gain Coefficient (SHGC)** | Windows & NFRC | Fraction of incident solar radiation admitted through a window, door, or skylight (0 to 1). Southern zones cap SHGC <= 0.23 to reject cooling load; Northern prescriptive permits >= 0.17. |
| **Air Leakage (AL)** | Windows & NFRC | Air infiltration rate measured in cfm/ft² under ASTM E283 / NFRC 400. ENERGY STAR v7.0 caps windows, sliding doors, and skylights at <= 0.3 cfm/ft² and swinging doors at <= 0.5 cfm/ft². |
| **Insulating Glass Unit (IGU)** | Windows & NFRC | Factory-sealed double- or triple-pane glass unit separated by dehydrated spacer bars and often argon/krypton gas fill. IGCC/IGMA corner etch stamps track plant ID and certification date. |
| **IRC Section R310 Egress Opening** | Building Codes | Mandatory emergency escape and rescue opening dimensions for bedrooms and basements: min 5.7 sq ft net clear opening (5.0 sq ft at grade), 24 in min height, 20 in min width, and 44 in max sill height. |
| **Pocket Insert Replacement** | Windows & NFRC | Window replacement fitted inside an existing wood/aluminum frame without removing exterior casing. Reduces clear opening width and height by roughly 1.5-2.5 in compared to full-frame replacement. |
| **FTC R-Value Rule (16 CFR Part 460)** | Insulation & FTC | Federal Trade Commission regulation requiring home insulation labels, fact sheets, ads, and installer receipts to cite standardized ASTM C177/C518 thermal resistance test values. |
| **16 CFR 460.20 R-per-Inch Rule** | Insulation & FTC | FTC prohibition against advertising flat 'R-value per inch' figures unless test data proves thermal efficiency per inch does not decline at thicker assemblies. |
| **Vapor Retarder Classes (IRC R702.7)** | Building Codes | Perm-rating classification (Class I <= 0.1 perm, Class II 0.1-1.0 perm, Class III 1.0-10 perm) governing moisture diffusion control in wall cavities by IECC climate zone. |
| **Thermal Barrier (IRC R316.4)** | Insulation & FTC | 15-minute fire barrier (typically 1/2-in gypsum wallboard) required to separate foam plastic insulation such as spray polyurethane foam from interior living spaces. |
| **Pre-1990 Vermiculite Insulation** | Safety & Hazards | Pebble-like expanded mica attic fill often mined in Libby, Montana and contaminated with asbestos. EPA directs homeowners to assume asbestos and never disturb or vacuum it. |
| **EPA Lead RRP Rule** | Safety & Hazards | Federal regulation requiring lead-safe firm certification for paid work disturbing painted surfaces in homes built prior to 1978, with 15 states running independent authorized programs. |
| **Light Reflectance Value (LRV)** | Siding & Gutters | 0-100 scale measuring visible light reflected by a coating. Standard vinyl siding paints generally require LRV >= 55 or specialized heat-reflective pigments to avoid ASTM D3679 thermal warping. |
| **Kickout Flashing** | Siding & Gutters | Angled diverter flashing at the lower end of a roof-to-wall intersection that channels roof runoff into the gutter instead of behind exterior siding. |
| **QMID (Qualified Manufacturer ID)** | 2026 Rebates | 4-character IRS manufacturer identifier required on Form 5695 for eligible Section 25C installations placed in service during 2025 before the credit sunset on Dec 31, 2025. |
| **DOE HOMES & HEEHR Rebates** | 2026 Rebates | Active U.S. DOE state-administered home energy rebate tracks funding modeled whole-home upgrades (up to $8,000 HOMES) and point-of-sale envelope insulation/air sealing (HEEHR up to $14,000 cap). |

## What practical thresholds govern these envelope definitions?

High-frequency conceptual questions explaining how U-Factor, SHGC, LRV 55, vapor classes, and 2026 rebates apply in the field appear below.

### How do NFRC U-Factor and SHGC differ when choosing residential windows?

U-Factor measures total non-solar heat conduction through the frame and glass (lower saves heating energy), whereas SHGC measures solar heat admitted (0 to 1—higher helps cold sunny zones, lower helps hot Southern climates).

### Who should NOT rely on R-value per inch when comparing attic insulation?

Homeowners comparing loose-fill cellulose vs. fiberglass should check full settled bag coverage charts at the target thickness rather than flat R-per-inch claims restricted by FTC 16 CFR 460.20.

### What triggers EPA Lead RRP requirements during exterior renovation?

Paid contractors disturbing over 20 sq ft of exterior painted surface—or replacing any pre-1978 painted window—must follow Lead-Safe containment, HEPA vacuuming, and written notice rules.

### What is the difference between pocket inserts and full-frame replacements?

Pocket inserts fit inside existing wood frames, preserving interior trim but shrinking bedroom egress clear width by ~2 inches, whereas full-frame exposes rough sills for ASTM E2112 sloped pan flashing.

### Why does IRC R702.7 ban interior plastic vapor barriers in warm climates?

Impermeable Class I polyethylene sheets on the inside of air-conditioned Southern walls trap inward summer humidity behind drywall, causing mold and sheathing decay.

### How does LRV 55 protect rigid vinyl siding during painting?

Light Reflectance Value >= 55 (or certified vinyl-safe heat-reflective pigments) reflects enough solar infrared radiation to keep PVC below ASTM D3679 heat distortion temperatures.

### Why did IRS Section 25C end while DOE HOMES and HEEHR remain active?

Section 25C federal tax credits applied only to installations finished through December 31, 2025; state-administered DOE HOMES ($8,000 cap) and HEEHR ($14,000 cap) operate across 2026+.

### How do homeowners check whether a county sits in an ENERGY STAR Northern or North-Central zone?

Use SillAndEave's 51-state atlas or individual county profiles to look up exact county-level ENERGY STAR v7.0 assignments and matching attic R-value tiers.

## Which official federal and state sources back this page?

Definitions trace directly to NFRC, EPA ENERGY STAR, FTC 16 CFR 460, IRS notices, and ICC code sections.

1.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
2.  [16 CFR Part 460 — Labeling and Advertising of Home Insulation (R-Value Rule)](https://www.ecfr.gov/current/title-16/chapter-I/subchapter-D/part-460) — **Federal Trade Commission (eCFR)**, eCFR Nov 18, 2026 (checked 2026-11-23)
3.  [Protect Your Family from Asbestos-Contaminated Vermiculite Insulation](https://www.epa.gov/asbestos/protect-your-family-asbestos-contaminated-vermiculite-insulation) — **U.S. Environmental Protection Agency**, 2026 (checked 2026-11-23)
4.  [Lead Renovation, Repair and Painting (RRP) Program & EPA-Authorized State Programs](https://www.epa.gov/lead/lead-renovation-repair-and-painting-program) — **U.S. Environmental Protection Agency**, 2026 (checked 2026-11-23)
5.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)
6.  [International Residential Code (IRC) — Sections R310 (Egress), R316.4 (Foam Barrier), R702.7 (Vapor Retarders), R703 (Exterior Covering)](https://codes.iccsafe.org/) — **International Code Council (ICC)**, 2021/2024 IRC (cite only) (checked 2026-11-23)
7.  [IGCC/IGMA Insulating Glass Unit Certification & Etch Stamp Identification Guidelines](https://igcc.org/) — **Insulating Glass Certification Council (IGCC)**, 2026 (checked 2026-11-23)
8.  [Home Energy Rebates Program (HOMES & HEEHR/HEAR)](https://www.energy.gov/scep/home-energy-rebates-programs) — **U.S. Department of Energy (SCEP)**, 2026 Program Guidance (checked 2026-11-23)

[Read Statutory Envelope FAQ](https://ela-ecolandscapingassn.org/faq/) [Browse All Official Sources](https://ela-ecolandscapingassn.org/sources/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)