---
title: "A Window SL3 Series Picture Window (15997 Frame) Specs"
url: https://ela-ecolandscapingassn.org/windows/models/a-window-inc-sl3-series-picture-window-15997-frame-413087/
description: "A Window SL3 Series Picture Window (15997 Frame) (AWN-M-24, Picture Window, Vinyl): U-Factor 0.21-0.32, SHGC 0.18-0.33, 477 options across 4 ENERGY STAR."
---

Window · Vinyl Frame NFRC AWN · Product Line AWN-M-24 ENERGY STAR Most Efficient Eligible

# A Window, Inc. — SL3 Series Picture Window (15997 Frame) · Picture Window

A Window, Inc. engineered the SL3 Series Picture Window (15997 Frame) Picture Window line for Northern, North-Central, South-Central, Southern, certifying 477 glass-spacer combinations from 0.21 to 0.32 U-Factor and 0.18 to 0.33 SHGC. Relative to other Vinyl models tracked under NFRC AWN, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.18-0.33

- **Certified Options** : 477

- **Category Standing** : #742 of 1,352

## How does A Window, Inc. SL3 Series Picture Window (15997 Frame) compare thermally against Window peers?

A Window, Inc. SL3 Series Picture Window (15997 Frame) achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places A Window, Inc. SL3 Series Picture Window (15997 Frame) at rank #742 of 1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.18-0.33 band.

Regional qualification covers Northern, North-Central, South-Central, Southern. 72 configurations meet ENERGY STAR Most Efficient criteria while 114 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-06-16 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 126.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 477 certified glazing combinations for SL3 Series Picture Window (15997 Frame) (NFRC AWN) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 114 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 320 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 288 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 384 packages (72 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**JELD-WEN, inc.** — Premium Altantic Vinyl Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-altantic-vinyl-fixed-413338/) | Vinyl | 0.21 | 0.14 | 478 |
| [**Westlake Royal Windows LLC** — 250 Fixed](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-250-fixed-414467/) | Vinyl | 0.21 | 0.18 | 503 |
| [**Windsor Windows and Doors** — Next Dimension Signature Radius and Direct Set](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-signature-radius-and-direct/) | Vinyl | 0.21 | 0.13 | 518 |
| [**MGM Industries** — 6010 Picture Window](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-picture-window-413725/) | Vinyl | 0.21 | 0.14 | 387 |
| [**MGM Industries** — 6010 Sloped Sill Picture Window](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-sloped-sill-picture-window-413730/) | Vinyl | 0.21 | 0.14 | 381 |

## What other certified series does A Window, Inc. produce?

Compare other active A Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.21

### [SL3 Series Picture Window (16059 Frame)](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-sl3-series-picture-window-16059-frame-413088/)

U-Factor 0.21–0.32 · 575 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-sl3-series-picture-window-16059-frame-413088/)

Picture WindowMin U 0.21

### [V-25 PW](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-25-pw-413080/)

U-Factor 0.21–0.32 · 627 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-25-pw-413080/)

Picture WindowMin U 0.21

### [V-31 PW](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-31-pw-413085/)

U-Factor 0.21–0.32 · 627 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-31-pw-413085/)

Sliding Patio DoorMin U 0.22

### [PD12 Patio Door](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-pd12-patio-door-413086/)

U-Factor 0.22–0.28 · 1,348 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-pd12-patio-door-413086/)

Single HungMin U 0.23

### [SL3 Series Single Hung](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-sl3-series-single-hung-413089/)

U-Factor 0.23–0.32 · 1,240 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-sl3-series-single-hung-413089/)

Single HungMin U 0.24

### [V-25/31 SH](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-25-31-sh-413081/)

U-Factor 0.24–0.32 · 980 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-25-31-sh-413081/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to A Window, Inc. SL3 Series Picture Window (15997 Frame) appear below.

### Where does A Window, Inc. SL3 Series Picture Window (15997 Frame) stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 477 configurations for A Window, Inc. SL3 Series Picture Window (15997 Frame) covering Northern, North-Central, South-Central, Southern, dropping down to U 0.21 versus a 0.20 Window median. Only 72 options earn Most Efficient status.

### Can homeowners install SL3 Series Picture Window (15997 Frame) in cold Northern ENERGY STAR counties?

Cold-climate buyers get 114 compliant Northern packages inside SL3 Series Picture Window (15997 Frame), reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

### What BTU/hr heat transfer results from SL3 Series Picture Window (15997 Frame)'s 0.21 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Who should NOT choose A Window, Inc. SL3 Series Picture Window (15997 Frame) for a residential project?

Skip SL3 Series Picture Window (15997 Frame) if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on SL3 Series Picture Window (15997 Frame) options exceeding U 0.22.

### Can you install A Window, Inc. SL3 Series Picture Window (15997 Frame) in Southern or South-Central zones?

Yes, SL3 Series Picture Window (15997 Frame) holds 384 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.18 SHGC in cooling climates.

### Does SL3 Series Picture Window (15997 Frame) carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 72 of 477 SL3 Series Picture Window (15997 Frame) glazing builds earn Most Efficient recognition (15.1%), while other variants sit on the standard Version 7.0 tier.

### What 2026 federal tax credit and Lead RRP rules apply to SL3 Series Picture Window (15997 Frame)?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 A Window, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do you cross-check NFRC AWN and product line AWN-M-24 on delivery?

Inspectors match the temporary NFRC sticker (U 0.21-0.32, SHGC 0.18-0.33) against permit drawings for line AWN-M-24. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for A Window, Inc. SL3 Series Picture Window (15997 Frame) come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
