---
title: "Advanced Window 5300 Picture Window Specs (U 0.19)"
url: https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-5300-picture-window-412863/
description: "Advanced Window 5300 Picture Window (ADC-K-26, Picture Window, Vinyl): U-Factor 0.19-0.31, SHGC 0.16-0.50, 195 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC ADC · Product Line ADC-K-26 ENERGY STAR Most Efficient Eligible

# Advanced Window Corp. — 5300 Picture Window · Picture Window

Advanced Window Corp. 5300 Picture Window is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.19 across 195 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #564 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.16 to 0.50.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.19

- **SHGC Range** : 0.16-0.50

- **Certified Options** : 195

- **Category Standing** : #564 of 1,352

## How does Advanced Window Corp. 5300 Picture Window compare thermally against Window peers?

Advanced Window Corp. 5300 Picture Window achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 5300 Picture Window reaches 0.19 on its lowest-conductivity package — #429 of 1,009 in Vinyl, tied with 83 others at 0.19, more insulating than 49.3% of Vinyl lines (At median vs Vinyl peers). Pairing NFRC ID ADC across multi-pane fills shifts U-Factor from 0.31 down toward 0.19.

Climate coverage for Advanced Window Corp. 5300 Picture Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 40 configurations meet ENERGY STAR Most Efficient criteria while 64 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-06-13 and cert timestamp 2024-01-22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 195 certified glazing combinations for 5300 Picture Window (NFRC ADC) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 64 packages (12 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 105 packages (24 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 83 packages (22 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 140 packages (38 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**L.A.S. Enterprises** — Weathergard II - Vinyl Double Hung](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-double-hung-413523/) | Vinyl | 0.19 | 0.14 | 210 |
| [**L.A.S. Enterprises** — Weathergard II - Vinyl Double Slider](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-double-slider-413522/) | Vinyl | 0.19 | 0.14 | 210 |
| [**Vinyl Design Corporation** — DuraTrust / TrustGard / TrustSeries Sash Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/vinyl-design-corporation-duratrust-trustgard-trustseries-sash-horizo/) | Vinyl | 0.19 | 0.17 | 210 |
| [**WeatherBarr Windows and Doors** — TrustGard Direct Set Picture Window](https://ela-ecolandscapingassn.org/windows/models/weatherbarr-windows-and-doors-trustgard-direct-set-picture-window-41/) | Vinyl | 0.19 | 0.18 | 213 |
| [**Northeast Building Products Corporation** — Elite Casement](https://ela-ecolandscapingassn.org/windows/models/northeast-building-products-corporation-elite-casement-413795/) | Vinyl | 0.19 | 0.15 | 173 |

## What other certified series does Advanced Window Corp. produce?

Compare other active Advanced Window Corp. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [EU 76 Septem Fixed](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-fixed-412865/)

U-Factor 0.13–0.26 · 300 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-fixed-412865/)

Picture WindowMin U 0.14

### [6300 Picture Window](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-picture-window-412858/)

U-Factor 0.14–0.27 · 408 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-picture-window-412858/)

Dual Action (Tilt Turn)Min U 0.14

### [EU 76 Septem Tilt Turn](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-tilt-turn-412866/)

U-Factor 0.14–0.26 · 324 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-tilt-turn-412866/)

Picture WindowMin U 0.15

### [6300 Large Picture Window](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-large-picture-window-412859/)

U-Factor 0.15–0.26 · 288 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-large-picture-window-412859/)

Swinging Entry Door (Single)Min U 0.15

### [EU 76 Septem Balcony Door](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-balcony-door-412868/)

U-Factor 0.15–0.25 · 360 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-balcony-door-412868/)

Casement WindowsMin U 0.16

### [6300 Casement](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-casement-412854/)

U-Factor 0.16–0.27 · 304 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-casement-412854/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Advanced Window Corp. 5300 Picture Window appear below.

### What thermal performance numbers separate Advanced Window Corp. 5300 Picture Window from peers?

Advanced Window Corp. 5300 Picture Window spans 195 certified configurations with U-Factors between 0.19 and 0.31 and SHGC values from 0.16 to 0.50. Ranked #564 of 1,352 Window families, it carries 40 Most Efficient options.

### Can homeowners install 5300 Picture Window in cold Northern ENERGY STAR counties?

Yes, 64 packages satisfy Northern ENERGY STAR Version 7.0 rules in 5300 Picture Window. Pairing multi-pane insulation down to 0.19 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How much winter heat loss does 5300 Picture Window conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Who should NOT choose Advanced Window Corp. 5300 Picture Window for a residential project?

Do not specify 5300 Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 5300 Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in 5300 Picture Window?

Across Northern, North-Central, South-Central, Southern, 140 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Advanced Window Corp. 5300 Picture Window, while total line SHGC reaches 0.50 in colder packages.

### Which package tier in 5300 Picture Window holds Most Efficient recognition?

EPA lists 40 Most Efficient options (20.5% share) inside Advanced Window Corp. 5300 Picture Window, out of 195 total Version 7.0 entries.

### Do 2026 5300 Picture Window installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 5300 Picture Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### Where are NFRC and IGCC identification marks located on 5300 Picture Window?

Verify NFRC ID ADC and series ADC-K-26 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Advanced Window Corp. 5300 Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
