Window · Vinyl Frame NFRC ADC · Product Line ADC-K-17 ENERGY STAR Most Efficient Eligible

# Advanced Window Corp. — 6300 Casement · Casement Windows

Across 16 Advanced Window Corp. certified families, 6300 Casement supplies 304 Casement Windows configurations starting at 0.16 U-Factor and 0.14 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.27 U-Factor and 0.41 SHGC. Its thermal floor ranks #250 of 1,352 category entries—0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.16

- **SHGC Range** : 0.14-0.41

- **Certified Options** : 304

- **Category Standing** : #250 of 1,352

## How does Advanced Window Corp. 6300 Casement compare thermally against Window peers?

Advanced Window Corp. 6300 Casement achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Advanced Window Corp. 6300 Casement at rank #250 of 1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.14-0.41 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 104 configurations meet ENERGY STAR Most Efficient criteria while 112 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-10-11 and FENSTAR license 2018-06-13 inside EPA Version 7.0 tables. Heat transfer computes to 96.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 304 certified glazing combinations for 6300 Casement (NFRC ADC) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 112 packages (40 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 216 packages (96 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 236 packages (72 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 236 packages (80 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**North Star Manufacturing (London) Ltd.** — 1171 Casement](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1171-casement-413829/) | Vinyl | 0.16 | 0.13 | 293 |
| [**North Star Manufacturing (London) Ltd.** — 1173 Awning](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1173-awning-413830/) | Vinyl | 0.16 | 0.13 | 291 |
| [**Amsco Windows** — VLS STC Serenity Awning](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-awning-412899/) | Vinyl | 0.16 | 0.08 | 288 |
| [**Amsco Windows** — VLS STC Serenity Casement](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-casement-412898/) | Vinyl | 0.16 | 0.08 | 288 |
| [**Crystal Window and Door Systems, Ltd.** — 235 Series Casement](https://ela-ecolandscapingassn.org/windows/models/crystal-window-and-door-systems-ltd-235-series-casement-413117/) | Vinyl | 0.16 | 0.14 | 277 |

## What other certified series does Advanced Window Corp. produce?

Compare other active Advanced Window Corp. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [EU 76 Septem Fixed](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-fixed-412865/)

U-Factor 0.13–0.26 · 300 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-fixed-412865/)

Picture WindowMin U 0.14

### [6300 Picture Window](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-picture-window-412858/)

U-Factor 0.14–0.27 · 408 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-picture-window-412858/)

Dual Action (Tilt Turn)Min U 0.14

### [EU 76 Septem Tilt Turn](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-tilt-turn-412866/)

U-Factor 0.14–0.26 · 324 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-tilt-turn-412866/)

Picture WindowMin U 0.15

### [6300 Large Picture Window](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-large-picture-window-412859/)

U-Factor 0.15–0.26 · 288 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-large-picture-window-412859/)

Swinging Entry Door (Single)Min U 0.15

### [EU 76 Septem Balcony Door](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-balcony-door-412868/)

U-Factor 0.15–0.25 · 360 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-balcony-door-412868/)

Picture WindowMin U 0.16

### [6300 Casement Picture Small](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-casement-picture-small-412862/)

U-Factor 0.16–0.29 · 201 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-casement-picture-small-412862/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Advanced Window Corp. 6300 Casement appear below.

### What thermal performance numbers separate Advanced Window Corp. 6300 Casement from peers?

Advanced Window Corp. 6300 Casement spans 304 certified configurations with U-Factors between 0.16 and 0.27 and SHGC values from 0.14 to 0.41. Ranked #250 of 1,352 Window families, it carries 104 Most Efficient options.

### Is 6300 Casement approved for Northern Zone heating climates?

Advanced Window Corp. 6300 Casement supplies 112 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.27, so inspect the NFRC order sheet before purchase.

### How do you calculate winter heat conduction for Advanced Window Corp. 6300 Casement?

Using NFRC ADC U-Factor 0.16, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 96.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-36.0 BTU/hr margin).

### What homeowner profiles are a poor match for Advanced Window Corp. 6300 Casement?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 6300 Casement options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### How many 6300 Casement glazing packages pass Southern solar-heat rules?

Yes, 6300 Casement holds 236 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.

### Which package tier in 6300 Casement holds Most Efficient recognition?

Not every package qualifies: 104 of 304 6300 Casement glazing builds earn Most Efficient recognition (34.2%), while other variants sit on the standard Version 7.0 tier.

### Do 2026 6300 Casement installations qualify for IRS Section 25C tax credits?

Any 6300 Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How can homeowners confirm delivered Advanced Window Corp. 6300 Casement units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code ADC and product line ADC-K-17, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Advanced Window Corp. 6300 Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)