title: "Advanced Window EU 76 Septem Tilt Turn Specs (U 0.14)"
url: https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-tilt-turn-412866/
description: "Advanced Window EU 76 Septem Tilt Turn (ADC-K-30, Dual Action (Tilt Turn), Vinyl): U-Factor 0.14-0.26, SHGC 0.13-0.43, 324 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC ADC · Product Line ADC-K-30 ENERGY STAR Most Efficient Eligible

# Advanced Window Corp. — EU 76 Septem Tilt Turn · Dual Action (Tilt Turn)

Advanced Window Corp. engineered the EU 76 Septem Tilt Turn Dual Action, Tilt Turn line for Northern, North-Central, South-Central, Southern, certifying 324 glass-spacer combinations from 0.14 to 0.26 U-Factor and 0.13 to 0.43 SHGC. Relative to other Vinyl models tracked under NFRC ADC, its minimum U-Factor is 0.05 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.14

- **SHGC Range** : 0.13-0.43

- **Certified Options** : 324

- **Category Standing** : #72 of 1,352

## How does Advanced Window Corp. EU 76 Septem Tilt Turn compare thermally against Window peers?

Advanced Window Corp. EU 76 Septem Tilt Turn achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Advanced Window Corp. EU 76 Septem Tilt Turn at rank #72 of 1,352 (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.13-0.43 band.

Regional qualification covers Northern, North-Central, South-Central, Southern. 102 configurations meet ENERGY STAR Most Efficient criteria while 132 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 84.0 BTU/hr (-36.4% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-06-13 and cert timestamp 2024-02-29.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 324 certified glazing combinations for EU 76 Septem Tilt Turn (NFRC ADC) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 132 packages (30 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 297 packages (72 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 201 packages (48 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 201 packages (78 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Vytex Corporation** — 6000 Potomac Series Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-fixed-414295/) | Vinyl | 0.14 | 0.14 | 316 |
| [**Pella Corporation** — 250 Series / Power Symphony Fixed](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-fixed-413894/) | Vinyl | 0.14 | 0.18 | 266 |
| [**Vinyl Design Corporation** — Casement Deadlite](https://ela-ecolandscapingassn.org/windows/models/vinyl-design-corporation-casement-deadlite-414237/) | Vinyl | 0.14 | 0.18 | 263 |
| [**ProVia LLC** — Wood Clad Vinyl Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-wood-clad-vinyl-picture-window-413944/) | Vinyl | 0.14 | 0.14 | 175 |
| [**Kasson and Keller** — 700 / 7000 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-picture-window-413410/) | Vinyl | 0.14 | 0.18 | 168 |

## What other certified series does Advanced Window Corp. produce?

Compare other active Advanced Window Corp. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [EU 76 Septem Fixed](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-fixed-412865/)

U-Factor 0.13–0.26 · 300 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-fixed-412865/)

Picture WindowMin U 0.14

### [6300 Picture Window](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-picture-window-412858/)

U-Factor 0.14–0.27 · 408 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-picture-window-412858/)

Picture WindowMin U 0.15

### [6300 Large Picture Window](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-large-picture-window-412859/)

U-Factor 0.15–0.26 · 288 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-large-picture-window-412859/)

Swinging Entry Door (Single)Min U 0.15

### [EU 76 Septem Balcony Door](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-balcony-door-412868/)

U-Factor 0.15–0.25 · 360 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-balcony-door-412868/)

Casement WindowsMin U 0.16

### [6300 Casement](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-casement-412854/)

U-Factor 0.16–0.27 · 304 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-casement-412854/)

Picture WindowMin U 0.16

### [6300 Casement Picture Small](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-casement-picture-small-412862/)

U-Factor 0.16–0.29 · 201 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-casement-picture-small-412862/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Advanced Window Corp. EU 76 Septem Tilt Turn appear below.

### How well does EU 76 Septem Tilt Turn by Advanced Window Corp. insulate relative to Window benchmarks?

Advanced Window Corp. EU 76 Septem Tilt Turn spans 324 certified configurations with U-Factors between 0.14 and 0.26 and SHGC values from 0.13 to 0.43. Ranked #72 of 1,352 Window families, it carries 102 Most Efficient options.

### Is EU 76 Septem Tilt Turn approved for Northern Zone heating climates?

Yes, 132 packages satisfy Northern ENERGY STAR Version 7.0 rules in EU 76 Septem Tilt Turn. Pairing multi-pane insulation down to 0.14 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How much winter heat loss does EU 76 Septem Tilt Turn conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.14 U-Factor yields 84.0 BTU/hr conductive transfer (-36.4% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Who should NOT choose Advanced Window Corp. EU 76 Septem Tilt Turn for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on EU 76 Septem Tilt Turn options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Can you install Advanced Window Corp. EU 76 Septem Tilt Turn in Southern or South-Central zones?

Yes, EU 76 Septem Tilt Turn holds 201 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

### What glazing share inside EU 76 Septem Tilt Turn qualifies as Most Efficient?

Only 102 options out of 324 (31.5%) meet tighter Most Efficient U-Factor and SHGC thresholds in Advanced Window Corp. EU 76 Septem Tilt Turn, usually requiring triple-pane or upgraded Low-E coatings.

### What federal compliance checks govern 2026 EU 76 Septem Tilt Turn window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current EU 76 Septem Tilt Turn retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### What permanent glass etch marks verify EU 76 Septem Tilt Turn after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line ADC-K-30 and NFRC ID ADC before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Advanced Window Corp. EU 76 Septem Tilt Turn come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)