title: "Amsco Windows V2K Basement Window Specs (U 0.24)"
url: https://ela-ecolandscapingassn.org/windows/models/amsco-windows-v2k-basement-window-412891/
description: "Amsco Windows V2K Basement Window (AMS-A-21, Single Slider, Vinyl): U-Factor 0.24-0.32, SHGC 0.13-0.51, 1114 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC AMS · Product Line AMS-A-21

# Amsco Windows — V2K Basement Window · Single Slider

Across 12 Amsco Windows certified families, V2K Basement Window supplies 1,114 Single Slider configurations starting at 0.24 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.51 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.13-0.51

- **Certified Options** : 1,114

- **Category Standing** : #1,034 of 1,352

## How does Amsco Windows V2K Basement Window compare thermally against Window peers?

Amsco Windows V2K Basement Window achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Amsco Windows V2K Basement Window standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 25 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors AMS to 2025-01-30 certification (FENSTAR issued 2018-10-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,114 certified glazing combinations for V2K Basement Window (NFRC AMS) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 25 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 165 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 449 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 1,035 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Seaway Manufacturing Corporation** — Amerivu Single Hung](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-amerivu-single-hung-414123/) | Vinyl | 0.24 | 0.13 | 1,062 |
| [**YKK AP America, Inc.** — Precedence / Style View / Style Guard Awning Window](https://ela-ecolandscapingassn.org/windows/models/ykk-ap-america-inc-precedence-style-view-style-guard-awning-window-4/) | Vinyl | 0.24 | 0.17 | 1,237 |
| [**A Window, Inc.** — V-25/31 SH](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-25-31-sh-413081/) | Vinyl | 0.24 | 0.15 | 980 |
| [**A Window, Inc.** — V-25/31 SS](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-25-31-ss-413082/) | Vinyl | 0.24 | 0.15 | 970 |
| [**Seaway Manufacturing Corporation** — Amerivu Single Slider](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-amerivu-single-slider-414122/) | Vinyl | 0.24 | 0.13 | 1,264 |

## What other certified series does Amsco Windows produce?

Compare other active Amsco Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Awning (Projected)Min U 0.16

### [VLS STC Serenity Awning](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-awning-412899/)

U-Factor 0.16–0.20 · 288 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-awning-412899/)

Casement WindowsMin U 0.16

### [VLS STC Serenity Casement](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-casement-412898/)

U-Factor 0.16–0.19 · 288 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-casement-412898/)

Picture WindowMin U 0.16

### [VLS STC Serenity Picture Window](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-picture-window-412894/)

U-Factor 0.16–0.26 · 1,272 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-picture-window-412894/)

Single SliderMin U 0.17

### [VLS STC Serenity Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-horizontal-slider-412892/)

U-Factor 0.17–0.24 · 912 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-horizontal-slider-412892/)

Single HungMin U 0.17

### [VLS STC Serenity Single Hung](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-single-hung-412893/)

U-Factor 0.17–0.24 · 912 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-single-hung-412893/)

Picture WindowMin U 0.17

### [VZ1 Hampton PM Fixed](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vz1-hampton-pm-fixed-412900/)

U-Factor 0.17–0.32 · 2,764 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vz1-hampton-pm-fixed-412900/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Amsco Windows V2K Basement Window appear below.

### How efficient is Amsco Windows V2K Basement Window compared with peer Window models?

Amsco Windows V2K Basement Window spans 1,114 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.13 to 0.51. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

### Which glazing options in Amsco Windows V2K Basement Window meet Northern climate limits?

With a 0.24 minimum U-Factor, Amsco Windows V2K Basement Window cannot satisfy prescriptive <= 0.22 Northern targets, yet 25 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

### How do you calculate winter heat conduction for Amsco Windows V2K Basement Window?

At U 0.24, a standard 3x5 ft (15 sq ft) V2K Basement Window opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

### Who should NOT choose Amsco Windows V2K Basement Window for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on V2K Basement Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Does V2K Basement Window meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 1,035 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Amsco Windows V2K Basement Window, while total line SHGC reaches 0.51 in colder packages.

### What glazing share inside V2K Basement Window qualifies as Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 1,114 V2K Basement Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### How do the 25C sunset and pre-1978 Lead RRP rules affect V2K Basement Window?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current V2K Basement Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do you cross-check NFRC AMS and product line AMS-A-21 on delivery?

Match the NFRC thermal sticker for code AMS and line AMS-A-21 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Amsco Windows V2K Basement Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)