---
title: "Amsco Windows VLS STC Serenity Awning Specs (U 0.16)"
url: https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-awning-412899/
description: "Amsco Windows VLS STC Serenity Awning (AMS-A-62, Awning (Projected), Vinyl): U-Factor 0.16-0.20, SHGC 0.08-0.33, 288 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC AMS · Product Line AMS-A-62 ENERGY STAR Most Efficient Eligible

# Amsco Windows — VLS STC Serenity Awning · Awning (Projected)

Amsco Windows engineered the VLS STC Serenity Awning Awning, Projected line for Northern, North-Central, South-Central, Southern, certifying 288 glass-spacer combinations from 0.16 to 0.20 U-Factor and 0.08 to 0.33 SHGC. Relative to other Vinyl models tracked under NFRC AMS, its minimum U-Factor is 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.16

- **SHGC Range** : 0.08-0.33

- **Certified Options** : 288

- **Category Standing** : #250 of 1,352

## How does Amsco Windows VLS STC Serenity Awning compare thermally against Window peers?

Amsco Windows VLS STC Serenity Awning achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 12 certified Amsco Windows series, this Awning, Projected offers a 0.04 U-Factor adjustment span between 0.20 entry options and 0.16 top-performing glazing. Category standing is #250/1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%).

Climate coverage for Amsco Windows VLS STC Serenity Awning spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 288 configurations meet ENERGY STAR Most Efficient criteria while 112 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-10-08 licensing and 2024-06-04 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 288 certified glazing combinations for VLS STC Serenity Awning (NFRC AMS) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 112 packages (56 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 288 packages (288 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 240 packages (240 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 240 packages (240 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**North Star Manufacturing (London) Ltd.** — 1173 Awning](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1173-awning-413830/) | Vinyl | 0.16 | 0.13 | 291 |
| [**North Star Manufacturing (London) Ltd.** — 1171 Casement](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1171-casement-413829/) | Vinyl | 0.16 | 0.13 | 293 |
| [**Crystal Window and Door Systems, Ltd.** — 235 Series Casement](https://ela-ecolandscapingassn.org/windows/models/crystal-window-and-door-systems-ltd-235-series-casement-413117/) | Vinyl | 0.16 | 0.14 | 277 |
| [**Advanced Window Corp.** — 6300 Casement](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-casement-412854/) | Vinyl | 0.16 | 0.14 | 304 |
| [**Vytex Corporation** — 6000 Potomac Double Hung](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-double-hung-414293/) | Vinyl | 0.16 | 0.12 | 268 |

## What other certified series does Amsco Windows produce?

Compare other active Amsco Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Casement WindowsMin U 0.16

### [VLS STC Serenity Casement](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-casement-412898/)

U-Factor 0.16–0.19 · 288 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-casement-412898/)

Picture WindowMin U 0.16

### [VLS STC Serenity Picture Window](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-picture-window-412894/)

U-Factor 0.16–0.26 · 1,272 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-picture-window-412894/)

Single SliderMin U 0.17

### [VLS STC Serenity Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-horizontal-slider-412892/)

U-Factor 0.17–0.24 · 912 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-horizontal-slider-412892/)

Single HungMin U 0.17

### [VLS STC Serenity Single Hung](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-single-hung-412893/)

U-Factor 0.17–0.24 · 912 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-single-hung-412893/)

Picture WindowMin U 0.17

### [VZ1 Hampton PM Fixed](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vz1-hampton-pm-fixed-412900/)

U-Factor 0.17–0.32 · 2,764 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vz1-hampton-pm-fixed-412900/)

Awning (Projected)Min U 0.18

### [VZ1 Hampton Awning](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vz1-hampton-awning-412902/)

U-Factor 0.18–0.32 · 3,114 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vz1-hampton-awning-412902/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Amsco Windows VLS STC Serenity Awning appear below.

### How well does VLS STC Serenity Awning by Amsco Windows insulate relative to Window benchmarks?

Built with Vinyl framing in Projected Awning (PRAW) style, Amsco Windows VLS STC Serenity Awning offers 288 Version 7.0 configurations from U 0.16 up to 0.20, posting -0.04 against the Window median of 0.20 with 288 Most Efficient picks.

### Is VLS STC Serenity Awning approved for Northern Zone heating climates?

Yes, 112 packages satisfy Northern ENERGY STAR Version 7.0 rules in VLS STC Serenity Awning. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How do you calculate winter heat conduction for Amsco Windows VLS STC Serenity Awning?

At U 0.16, a standard 3x5 ft (15 sq ft) VLS STC Serenity Awning opening transfers 96.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -36.0 BTU/hr difference.

### What are the practical limitations of specifying VLS STC Serenity Awning?

Project owners who ignore local NFRC zone limits risk permit rejection. Hot Southern owners needing SHGC <= 0.23 must avoid higher-solar VLS STC Serenity Awning options near 0.33 SHGC. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### How many VLS STC Serenity Awning glazing packages pass Southern solar-heat rules?

Yes, VLS STC Serenity Awning holds 240 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.08 SHGC in cooling climates.

### Which package tier in VLS STC Serenity Awning holds Most Efficient recognition?

Only 288 options out of 288 (100.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in Amsco Windows VLS STC Serenity Awning, usually requiring triple-pane or upgraded Low-E coatings.

### Can homeowners claim Form 5695 credits on Amsco Windows VLS STC Serenity Awning in 2026?

Any VLS STC Serenity Awning purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do building inspectors verify VLS STC Serenity Awning glass specs on job sites?

Verify NFRC ID AMS and series AMS-A-62 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Amsco Windows VLS STC Serenity Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
