Window · Vinyl Frame NFRC AMS · Product Line AMS-A-77 ENERGY STAR Most Efficient Eligible

# Amsco Windows — VZ1 Hampton PM Fixed · Picture Window

Amsco Windows engineered the VZ1 Hampton PM Fixed Picture Window line for Northern, North-Central, South-Central, Southern, certifying 2,764 glass-spacer combinations from 0.17 to 0.32 U-Factor and 0.11 to 0.48 SHGC. Relative to other Vinyl models tracked under NFRC AMS, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.11-0.48

- **Certified Options** : 2,764

- **Category Standing** : #362 of 1,352

## How does Amsco Windows VZ1 Hampton PM Fixed compare thermally against Window peers?

Amsco Windows VZ1 Hampton PM Fixed achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Amsco Windows VZ1 Hampton PM Fixed at rank #362 of 1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.11-0.48 band.

Mapping NFRC SHGC values (0.11 to 0.48) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 307 configurations meet ENERGY STAR Most Efficient criteria while 436 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-10-08 and v7.0 data certification on 2026-06-09. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,764 certified glazing combinations for VZ1 Hampton PM Fixed (NFRC AMS) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 436 packages (34 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,252 packages (92 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 1,654 packages (72 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,248 packages (284 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Vinylmax LLC** — DSA4 Double Slider](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-dsa4-double-slider-414265/) | Vinyl | 0.17 | 0.14 | 2,757 |
| [**Sierra Pacific Windows** — Vinyl Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-vinyl-direct-set-414078/) | Vinyl | 0.17 | 0.12 | 2,077 |
| [**Wincore Window Company, LLC** — 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-5400s-7700-9900-series-vinyl-fixed-w/) | Vinyl | 0.17 | 0.14 | 1,833 |
| [**DRUTEX S.A.** — IGLO 5 Classic Tilt Turn](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-tilt-turn-413146/) | Vinyl | 0.17 | 0.04 | 1,631 |
| [**Windsor Windows and Doors** — Next Dimension Casement Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-casement-picture-414454/) | Vinyl | 0.17 | 0.12 | 1,610 |

## What other certified series does Amsco Windows produce?

Compare other active Amsco Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Awning (Projected)Min U 0.16

### [VLS STC Serenity Awning](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-awning-412899/)

U-Factor 0.16–0.20 · 288 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-awning-412899/)

Casement WindowsMin U 0.16

### [VLS STC Serenity Casement](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-casement-412898/)

U-Factor 0.16–0.19 · 288 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-casement-412898/)

Picture WindowMin U 0.16

### [VLS STC Serenity Picture Window](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-picture-window-412894/)

U-Factor 0.16–0.26 · 1,272 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-picture-window-412894/)

Single SliderMin U 0.17

### [VLS STC Serenity Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-horizontal-slider-412892/)

U-Factor 0.17–0.24 · 912 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-horizontal-slider-412892/)

Single HungMin U 0.17

### [VLS STC Serenity Single Hung](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-single-hung-412893/)

U-Factor 0.17–0.24 · 912 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-single-hung-412893/)

Awning (Projected)Min U 0.18

### [VZ1 Hampton Awning](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vz1-hampton-awning-412902/)

U-Factor 0.18–0.32 · 3,114 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vz1-hampton-awning-412902/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Amsco Windows VZ1 Hampton PM Fixed appear below.

### How well does VZ1 Hampton PM Fixed by Amsco Windows insulate relative to Window benchmarks?

Built with Vinyl framing in Fixed Window (FIXD) style, Amsco Windows VZ1 Hampton PM Fixed offers 2,764 Version 7.0 configurations from U 0.17 up to 0.32, posting -0.03 against the Window median of 0.20 with 307 Most Efficient picks.

### Which glazing options in Amsco Windows VZ1 Hampton PM Fixed meet Northern climate limits?

Prescriptive Northern compliance covers 436 VZ1 Hampton PM Fixed packages (U floor 0.17, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### How does a 3x5 ft VZ1 Hampton PM Fixed window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 102.0 BTU/hr on VZ1 Hampton PM Fixed's lowest-U package (0.17), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### Who should NOT choose Amsco Windows VZ1 Hampton PM Fixed for a residential project?

Skip VZ1 Hampton PM Fixed if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on VZ1 Hampton PM Fixed options exceeding U 0.22.

### How many VZ1 Hampton PM Fixed glazing packages pass Southern solar-heat rules?

Exactly 2,248 VZ1 Hampton PM Fixed options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.11 rather than higher 0.48 glass.

### What glazing share inside VZ1 Hampton PM Fixed qualifies as Most Efficient?

EPA lists 307 Most Efficient options (11.1% share) inside Amsco Windows VZ1 Hampton PM Fixed, out of 2,764 total Version 7.0 entries.

### What 2026 federal tax credit and Lead RRP rules apply to VZ1 Hampton PM Fixed?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current VZ1 Hampton PM Fixed retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How can homeowners confirm delivered Amsco Windows VZ1 Hampton PM Fixed units match permits?

Match the NFRC thermal sticker for code AMS and line AMS-A-77 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Amsco Windows VZ1 Hampton PM Fixed come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)