title: "Andersen 100 Series/Series 2 Fixed/Specialty Windows Specs"
url: https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/
description: "Andersen 100 Series/Series 2 Fixed/Specialty Windows (AND-N-82, Picture Window, Composite / Vinyl): U-Factor 0.14-0.32, SHGC 0.13-0.54, 13810 options across."
---

Window · Composite / Vinyl Frame NFRC AND · Product Line AND-N-82 ENERGY STAR Most Efficient Eligible

# Andersen Corporation — 100 Series/Series 2 Fixed/Specialty Windows · Picture Window

With a minimum U-Factor of 0.14—-0.06 compared against the 0.20 Window median—Andersen Corporation 100 Series/Series 2 Fixed/Specialty Windows spans 13,810 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code AND, the Composite / Vinyl assembly includes 2,845 ENERGY STAR Most Efficient packages (20.6% of line) and offers SHGC packages between 0.13 and 0.54.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.14

- **SHGC Range** : 0.13-0.54

- **Certified Options** : 13,810

- **Category Standing** : #72 of 1,352

## How does Andersen Corporation 100 Series/Series 2 Fixed/Specialty Windows compare thermally against Window peers?

Andersen Corporation 100 Series/Series 2 Fixed/Specialty Windows achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 111 certified Andersen Corporation series, this Picture Window offers a 0.18 U-Factor adjustment span between 0.32 entry options and 0.14 top-performing glazing. Category standing is #72/1,352 (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%).

Regional qualification covers Northern, North-Central, South-Central, Southern. 2,845 configurations meet ENERGY STAR Most Efficient criteria while 3,331 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors AND to 2025-06-06 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 84.0 BTU/hr conductive loss (-36.4% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 13,810 certified glazing combinations for 100 Series/Series 2 Fixed/Specialty Windows (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 3,331 packages (1,157 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 6,397 packages (2,149 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 7,238 packages (1,215 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 10,264 packages (1,819 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Harvey Industries, Inc.** — Vinyl Fixed Casement Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-vinyl-fixed-casement-window-413303/) | Vinyl | 0.14 | 0.17 | 14,146 |
| [**Associated Materials, Inc.** — A171 Picture](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a171-picture-413073/) | Vinyl | 0.14 | 0.07 | 12,246 |
| [**Marvin** — Ultimate Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-round-top-413621/) | Wood | 0.14 | 0.13 | 17,250 |
| [**Quaker Window Products** — V300 Direct Set Narrow](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-direct-set-narrow-413983/) | Vinyl | 0.14 | 0.11 | 9,693 |
| [**Marvin** — Ultimate Direct Glaze Narrow Frame Rectangle](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-narrow-frame-rectangle-413631/) | Wood | 0.14 | 0.13 | 21,304 |

## What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [Complementary Wood Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

U-Factor 0.14–0.32 · 7,588 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

Picture WindowMin U 0.15

### [200 Series/400 Series Complementary Clad Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

U-Factor 0.15–0.32 · 12,778 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

Picture WindowMin U 0.15

### [400 Series Tilt-Wash Double-Hung Transom Full-Frame Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

U-Factor 0.15–0.32 · 2,446 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

Picture WindowMin U 0.15

### [E-Series Specialty (Auxiliary) Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

U-Factor 0.15–0.32 · 16,775 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

SideliteMin U 0.15

### [Renewal by Andersen® Entry Door – Panel Set Sidelight](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

U-Factor 0.15–0.28 · 24,853 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

Picture WindowMin U 0.16

### [400 Series Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-casement-fixed-412924/)

U-Factor 0.16–0.32 · 3,248 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-casement-fixed-412924/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 100 Series/Series 2 Fixed/Specialty Windows appear below.

### Where does Andersen Corporation 100 Series/Series 2 Fixed/Specialty Windows stand thermally among ENERGY STAR Window lines?

Across 13,810 tested NFRC glazing configurations, Andersen Corporation 100 Series/Series 2 Fixed/Specialty Windows with Composite / Vinyl framing and Fixed Window (FIXD) style reaches a 0.14 minimum U-Factor and 0.13-0.54 SHGC band. It places #72 among 1,352 Window series—top 10.0%.

### Which glazing options in Andersen Corporation 100 Series/Series 2 Fixed/Specialty Windows meet Northern climate limits?

Andersen Corporation 100 Series/Series 2 Fixed/Specialty Windows supplies 3,331 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

### How much winter heat loss does 100 Series/Series 2 Fixed/Specialty Windows conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 100 Series/Series 2 Fixed/Specialty Windows at U 0.14 conducts 84.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Who should NOT choose Andersen Corporation 100 Series/Series 2 Fixed/Specialty Windows for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 100 Series/Series 2 Fixed/Specialty Windows options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Is 100 Series/Series 2 Fixed/Specialty Windows suitable for sunbelt cooling-dominated homes?

Yes. 10,264 Southern-certified options inside Andersen Corporation 100 Series/Series 2 Fixed/Specialty Windows satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.54 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Which package tier in 100 Series/Series 2 Fixed/Specialty Windows holds Most Efficient recognition?

No. Exactly 2,845 of 13,810 configurations (20.6%) earn ENERGY STAR Most Efficient status in 100 Series/Series 2 Fixed/Specialty Windows; the remaining standard v7.0 options pass base zone limits only.

### Do 2026 100 Series/Series 2 Fixed/Specialty Windows installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 100 Series/Series 2 Fixed/Specialty Windows retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do building inspectors verify 100 Series/Series 2 Fixed/Specialty Windows glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.14-0.32, SHGC 0.13-0.54) against permit drawings for line AND-N-82. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 100 Series/Series 2 Fixed/Specialty Windows come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)