---
title: "Andersen 100 Series/Series 2 Gliding Patio Door Sidelight"
url: https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-gliding-patio-door-sideligh/
description: "Andersen 100 Series/Series 2 Gliding Patio Door Sidelight (AND-N-97, Sidelite, Composite): U-Factor 0.27-0.28, SHGC 0.12-0.23, 153 options across 2 ENERGY."
---

Window · Composite Frame NFRC AND · Product Line AND-N-97

# Andersen Corporation — 100 Series/Series 2 Gliding Patio Door Sidelight · Sidelite

Positioning #1,292/1,352 in certified Window, Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight pairs Composite frame construction with 153 glazing options rated between 0.12 and 0.23 SHGC across South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.27 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.27

- **SHGC Range** : 0.12-0.23

- **Certified Options** : 153

- **Category Standing** : #1,292 of 1,352

## How does Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight compare thermally against Window peers?

Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Composite cohort (0.22 median U-Factor), 100 Series/Series 2 Gliding Patio Door Sidelight reaches 0.27 on its lowest-conductivity package — #19 of 21 in Composite, tied with 1 other at 0.27, more insulating than 4.8% of Composite lines (+0.05 vs Composite peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.28 down toward 0.27.

Mapping NFRC SHGC values (0.12 to 0.23) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Lifecycle documentation anchors AND to 2024-03-07 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 162.0 BTU/hr conductive loss (+22.7% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 153 certified glazing combinations for 100 Series/Series 2 Gliding Patio Door Sidelight (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 153 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 153 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Custom Window Systems, Inc.** — A-8450 Awning](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-a-8450-awning-413139/) | Vinyl | 0.27 | 0.11 | 194 |
| [**Custom Window Systems, Inc.** — C-8400 Casement](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-c-8400-casement-413138/) | Vinyl | 0.27 | 0.11 | 195 |
| [**Weather Shield Mfg., Inc.** — 8401 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8401-horizontal-slider-414353/) | Wood | 0.27 | 0.11 | 198 |
| [**ViWinTech Window** — Casement](https://ela-ecolandscapingassn.org/windows/models/viwintech-window-casement-414269/) | Vinyl | 0.27 | 0.16 | 204 |
| [**Windsor Windows and Doors** — Revive Clad Pocket Double Hung](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-revive-clad-pocket-double-hung-414440/) | Wood | 0.27 | 0.11 | 241 |

## What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [100 Series/Series 2 Fixed/Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/)

U-Factor 0.14–0.32 · 13,810 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/)

Picture WindowMin U 0.14

### [Complementary Wood Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

U-Factor 0.14–0.32 · 7,588 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

Picture WindowMin U 0.15

### [200 Series/400 Series Complementary Clad Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

U-Factor 0.15–0.32 · 12,778 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

Picture WindowMin U 0.15

### [400 Series Tilt-Wash Double-Hung Transom Full-Frame Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

U-Factor 0.15–0.32 · 2,446 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

Picture WindowMin U 0.15

### [E-Series Specialty (Auxiliary) Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

U-Factor 0.15–0.32 · 16,775 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

SideliteMin U 0.15

### [Renewal by Andersen® Entry Door – Panel Set Sidelight](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

U-Factor 0.15–0.28 · 24,853 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight appear below.

### How well does 100 Series/Series 2 Gliding Patio Door Sidelight by Andersen Corporation insulate relative to Window benchmarks?

Testing puts Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight at rank #1,292 of 1,352 Window entries with U 0.27 to 0.28 across 153 configurations. Solar heat gain ranges between 0.12 and 0.23 across South-Central, Southern.

### Does Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight qualify for the ENERGY STAR Northern Zone?

No—with 0 Northern packages and a 0.27 thermal floor, Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight targets warmer South-Central, Southern climates instead of cold Northern installations.

### How do you calculate winter heat conduction for Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight?

Using NFRC AND U-Factor 0.27, a 15 sq ft Fixed Sidelite (FXSL) assembly conducts 162.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+30.0 BTU/hr margin).

### What are the practical limitations of specifying 100 Series/Series 2 Gliding Patio Door Sidelight?

Do not specify 100 Series/Series 2 Gliding Patio Door Sidelight without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 100 Series/Series 2 Gliding Patio Door Sidelight options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does 100 Series/Series 2 Gliding Patio Door Sidelight meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, 100 Series/Series 2 Gliding Patio Door Sidelight holds 153 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.12 SHGC in cooling climates.

### Which package tier in 100 Series/Series 2 Gliding Patio Door Sidelight holds Most Efficient recognition?

Zero glazing builds inside 100 Series/Series 2 Gliding Patio Door Sidelight's 153 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### Do 2026 100 Series/Series 2 Gliding Patio Door Sidelight installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do building inspectors verify 100 Series/Series 2 Gliding Patio Door Sidelight glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code AND and product line AND-N-97, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
