---
title: "Andersen 100 Series/Series 2 Transom Window Specs (U 0.24)"
url: https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-transom-window-412941/
description: "Andersen 100 Series/Series 2 Transom Window (AND-N-83, Picture Window, Composite): U-Factor 0.24-0.32, SHGC 0.16-0.50, 619 options across 4 ENERGY STAR zones."
---

Window · Composite Frame NFRC AND · Product Line AND-N-83

# Andersen Corporation — 100 Series/Series 2 Transom Window · Picture Window

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—Andersen Corporation 100 Series/Series 2 Transom Window spans 619 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code AND, the Composite assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.16 and 0.50.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.16-0.50

- **Certified Options** : 619

- **Category Standing** : #1,034 of 1,352

## How does Andersen Corporation 100 Series/Series 2 Transom Window compare thermally against Window peers?

Andersen Corporation 100 Series/Series 2 Transom Window achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Andersen Corporation 100 Series/Series 2 Transom Window at rank #1,034 of 1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.16-0.50 band.

Mapping NFRC SHGC values (0.16 to 0.50) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 16 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2026-09-25 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 619 certified glazing combinations for 100 Series/Series 2 Transom Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 16 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 44 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 244 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 591 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Krestmark Industries L. P.** — 400/4000 Single Hung](https://ela-ecolandscapingassn.org/windows/models/krestmark-industries-l-p-400-4000-single-hung-413503/) | Vinyl | 0.24 | 0.17 | 591 |
| [**Associated Materials, Inc.** — 0700 Single Hung](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-0700-single-hung-413042/) | Vinyl | 0.24 | 0.09 | 586 |
| [**Harvey Industries, Inc.** — Slimline Fully Welded DH / SH](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-slimline-fully-welded-dh-sh-413300/) | Vinyl | 0.24 | 0.17 | 568 |
| [**Windsor Windows and Doors** — Pinnacle Primed Double Hung](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-primed-double-hung-414395/) | Other | 0.24 | 0.14 | 550 |
| [**Vinylmax LLC** — SH46 Single Hung](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-sh46-single-hung-414261/) | Vinyl | 0.24 | 0.19 | 690 |

## What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [100 Series/Series 2 Fixed/Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/)

U-Factor 0.14–0.32 · 13,810 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/)

Picture WindowMin U 0.14

### [Complementary Wood Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

U-Factor 0.14–0.32 · 7,588 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

Picture WindowMin U 0.15

### [200 Series/400 Series Complementary Clad Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

U-Factor 0.15–0.32 · 12,778 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

Picture WindowMin U 0.15

### [400 Series Tilt-Wash Double-Hung Transom Full-Frame Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

U-Factor 0.15–0.32 · 2,446 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

Picture WindowMin U 0.15

### [E-Series Specialty (Auxiliary) Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

U-Factor 0.15–0.32 · 16,775 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

SideliteMin U 0.15

### [Renewal by Andersen® Entry Door – Panel Set Sidelight](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

U-Factor 0.15–0.28 · 24,853 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 100 Series/Series 2 Transom Window appear below.

### Where does Andersen Corporation 100 Series/Series 2 Transom Window stand thermally among ENERGY STAR Window lines?

Testing puts Andersen Corporation 100 Series/Series 2 Transom Window at rank #1,034 of 1,352 Window entries with U 0.24 to 0.32 across 619 configurations. Solar heat gain ranges between 0.16 and 0.50 across Northern, North-Central, South-Central, Southern.

### Can homeowners install 100 Series/Series 2 Transom Window in cold Northern ENERGY STAR counties?

Prescriptive Northern approval ends at U <= 0.22, above 100 Series/Series 2 Transom Window's 0.24 minimum. However, 16 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

### How do you calculate winter heat conduction for Andersen Corporation 100 Series/Series 2 Transom Window?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 100 Series/Series 2 Transom Window at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What are the practical limitations of specifying 100 Series/Series 2 Transom Window?

Skip 100 Series/Series 2 Transom Window if local historic preservation boards prohibit Composite profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 100 Series/Series 2 Transom Window options exceeding U 0.22.

### How many 100 Series/Series 2 Transom Window glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 591 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation 100 Series/Series 2 Transom Window, while total line SHGC reaches 0.50 in colder packages.

### Are all 619 100 Series/Series 2 Transom Window configurations ENERGY STAR Most Efficient?

Zero glazing builds inside 100 Series/Series 2 Transom Window's 619 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### Can homeowners claim Form 5695 credits on Andersen Corporation 100 Series/Series 2 Transom Window in 2026?

Any 100 Series/Series 2 Transom Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do you cross-check NFRC AND and product line AND-N-83 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-83 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 100 Series/Series 2 Transom Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
