Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window is a Double Hung assembly with a Wood frame that reaches a minimum U-Factor of 0.26 across 326 certified glazing configurations covering South-Central, Southern. Ranked #1,256 of 1,352 in Window, its thermal floor is 0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.23.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.26

- **SHGC Range** : 0.14-0.23

- **Certified Options** : 326

- **Category Standing** : #1,256 of 1,352

## How does Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window compare thermally against Window peers?

Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 400 Series Tilt-Wash Double-Hung Insert Window is 0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.26-0.32.

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.14 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.26 U-Factor yields 156.0 BTU/hr transfer (+24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2025-04-11 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 326 certified glazing combinations for 400 Series Tilt-Wash Double-Hung Insert Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 60 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 326 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Windsor Windows and Doors** — Pinnacle Clad Win-Pac](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-win-pac-414426/) | Wood | 0.26 | 0.14 | 267 |
| [**Lincoln Wood Products, Inc.** — Clad Door Transom](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-clad-door-transom-414178/) | Wood | 0.26 | 0.14 | 102 |
| [**JELD-WEN, inc.** — Siteline EX Clad Wood Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-ex-clad-wood-horizontal-slider-413348/) | Wood | 0.26 | 0.12 | 89 |
| [**Harvey Industries, Inc.** — Majesty Casement Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-majesty-casement-window-413295/) | Wood | 0.26 | 0.16 | 59 |
| [**Lincoln Wood Products, Inc.** — Wood Awning - Push-Out & Crank-Out](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-wood-awning-push-out-crank-out-414188/) | Wood | 0.26 | 0.15 | 37 |

## What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [100 Series/Series 2 Fixed/Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/)

U-Factor 0.14–0.32 · 13,810 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/)

Picture WindowMin U 0.14

### [Complementary Wood Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

U-Factor 0.14–0.32 · 7,588 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

Picture WindowMin U 0.15

### [200 Series/400 Series Complementary Clad Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

U-Factor 0.15–0.32 · 12,778 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

Picture WindowMin U 0.15

### [400 Series Tilt-Wash Double-Hung Transom Full-Frame Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

U-Factor 0.15–0.32 · 2,446 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

Picture WindowMin U 0.15

### [E-Series Specialty (Auxiliary) Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

U-Factor 0.15–0.32 · 16,775 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

SideliteMin U 0.15

### [Renewal by Andersen® Entry Door – Panel Set Sidelight](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

U-Factor 0.15–0.28 · 24,853 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window appear below.

### How well does 400 Series Tilt-Wash Double-Hung Insert Window by Andersen Corporation insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 326 configurations for Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window covering South-Central, Southern, dropping down to U 0.26 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Can homeowners install 400 Series Tilt-Wash Double-Hung Insert Window in cold Northern ENERGY STAR counties?

No—with 0 Northern packages and a 0.26 thermal floor, Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window targets warmer South-Central, Southern climates instead of cold Northern installations.

### What conductive BTU/hr difference separates 400 Series Tilt-Wash Double-Hung Insert Window from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.26 U-Factor yields 156.0 BTU/hr conductive transfer (+18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What are the practical limitations of specifying 400 Series Tilt-Wash Double-Hung Insert Window?

Skip 400 Series Tilt-Wash Double-Hung Insert Window if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Tilt-Wash Double-Hung Insert Window options exceeding U 0.22.

### Can you install Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window in Southern or South-Central zones?

Across South-Central, Southern, 326 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window, while total line SHGC reaches 0.23 in colder packages.

### Which package tier in 400 Series Tilt-Wash Double-Hung Insert Window holds Most Efficient recognition?

Zero glazing builds inside 400 Series Tilt-Wash Double-Hung Insert Window's 326 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### What federal compliance checks govern 2026 400 Series Tilt-Wash Double-Hung Insert Window window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on 400 Series Tilt-Wash Double-Hung Insert Window?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-132 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Tilt-Wash Double-Hung Insert Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)