---
title: "Andersen A-Series Frenchwood® Patio FXTR [AND-N-95]"
url: https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-a-series-frenchwood-patio-door-transom-sash-set/
description: "Andersen A-Series Frenchwood® Patio Door Transom - Sash-Set (AND-N-95, Transom, Wood): U-Factor 0.23-0.32, SHGC 0.11-0.33, 3861 options across 3 ENERGY STAR."
---

Window · Wood Frame NFRC AND · Product Line AND-N-95

# Andersen Corporation — A-Series Frenchwood® Patio Door Transom - Sash-Set · Transom

Andersen Corporation engineered the A-Series Frenchwood® Patio Door Transom - Sash-Set Transom line for North-Central, South-Central, Southern, certifying 3,861 glass-spacer combinations from 0.23 to 0.32 U-Factor and 0.11 to 0.33 SHGC. Relative to other Wood models tracked under NFRC AND, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.11-0.33

- **Certified Options** : 3,861

- **Category Standing** : #936 of 1,352

## How does Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set compare thermally against Window peers?

Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.02 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.11 to 0.33) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Lifecycle documentation anchors AND to 2024-03-07 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,861 certified glazing combinations for A-Series Frenchwood® Patio Door Transom - Sash-Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 128 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 852 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 3,829 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Marvin** — Ultimate Glider Picture](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-glider-picture-413610/) | Wood | 0.23 | 0.11 | 2,132 |
| [**Marvin** — Ultimate Wood Double Hung Picture 1 5/8 inch Sash](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-picture-1-5-8-inch-sash-413557/) | Wood | 0.23 | 0.11 | 1,700 |
| [**Windsor Windows and Doors** — Legend Double Hung Transom](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-legend-double-hung-transom-414401/) | Wood | 0.23 | 0.10 | 777 |
| [**JELD-WEN, inc.** — Custom Clad Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-custom-clad-casement-413357/) | Wood | 0.23 | 0.11 | 774 |
| [**JELD-WEN, inc.** — Custom Clad Casement In Sash Geometric](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-custom-clad-casement-in-sash-geometric-413358/) | Wood | 0.23 | 0.11 | 745 |

## What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [100 Series/Series 2 Fixed/Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/)

U-Factor 0.14–0.32 · 13,810 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/)

Picture WindowMin U 0.14

### [Complementary Wood Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

U-Factor 0.14–0.32 · 7,588 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

Picture WindowMin U 0.15

### [200 Series/400 Series Complementary Clad Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

U-Factor 0.15–0.32 · 12,778 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

Picture WindowMin U 0.15

### [400 Series Tilt-Wash Double-Hung Transom Full-Frame Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

U-Factor 0.15–0.32 · 2,446 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

Picture WindowMin U 0.15

### [E-Series Specialty (Auxiliary) Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

U-Factor 0.15–0.32 · 16,775 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

SideliteMin U 0.15

### [Renewal by Andersen® Entry Door – Panel Set Sidelight](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

U-Factor 0.15–0.28 · 24,853 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set appear below.

### What U-Factor and SHGC range does Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set achieve?

EPA ENERGY STAR v7.0 records 3,861 configurations for Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set covering North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Can homeowners install A-Series Frenchwood® Patio Door Transom - Sash-Set in cold Northern ENERGY STAR counties?

Northern Zone certification is absent for A-Series Frenchwood® Patio Door Transom - Sash-Set (0 qualifying options, min U 0.23). Install this Fixed Transom (FXTR) product only within North-Central, South-Central, Southern regions where lower SHGC caps apply.

### How do you calculate winter heat conduction for Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 138.0 BTU/hr on A-Series Frenchwood® Patio Door Transom - Sash-Set's lowest-U package (0.23), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### Which situations make A-Series Frenchwood® Patio Door Transom - Sash-Set the wrong window or door choice?

Do not specify A-Series Frenchwood® Patio Door Transom - Sash-Set without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Frenchwood® Patio Door Transom - Sash-Set options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Can you install Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set in Southern or South-Central zones?

Across North-Central, South-Central, Southern, 3,829 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set, while total line SHGC reaches 0.33 in colder packages.

### What glazing share inside A-Series Frenchwood® Patio Door Transom - Sash-Set qualifies as Most Efficient?

A-Series Frenchwood® Patio Door Transom - Sash-Set holds zero Most Efficient entries across its 3,861 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

### How do the 25C sunset and pre-1978 Lead RRP rules affect A-Series Frenchwood® Patio Door Transom - Sash-Set?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on A-Series Frenchwood® Patio Door Transom - Sash-Set?

Inspectors match the temporary NFRC sticker (U 0.23-0.32, SHGC 0.11-0.33) against permit drawings for line AND-N-95. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
