---
title: "Andersen A-Series Picture Window Specs (U 0.18)"
url: https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-a-series-picture-window-412946/
description: "Andersen A-Series Picture Window (AND-N-88, Picture Window, Wood): U-Factor 0.18-0.32, SHGC 0.12-0.47, 5913 options across 4 ENERGY STAR zones."
---

Window · Wood Frame NFRC AND · Product Line AND-N-88 ENERGY STAR Most Efficient Eligible

# Andersen Corporation — A-Series Picture Window · Picture Window

Andersen Corporation A-Series Picture Window is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.18 across 5,913 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #477 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.47.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.18

- **SHGC Range** : 0.12-0.47

- **Certified Options** : 5,913

- **Category Standing** : #477 of 1,352

## How does Andersen Corporation A-Series Picture Window compare thermally against Window peers?

Andersen Corporation A-Series Picture Window achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), A-Series Picture Window is 0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.18-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. 212 configurations meet ENERGY STAR Most Efficient criteria while 366 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-03-12 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 108.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 5,913 certified glazing combinations for A-Series Picture Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 366 packages (76 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,294 packages (154 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 2,713 packages (100 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 5,291 packages (156 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Marvin** — Ultimate Double Hung Transom G2](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-double-hung-transom-g2-413624/) | Wood | 0.18 | 0.11 | 4,043 |
| [**Weather Shield Mfg., Inc.** — 6121 Double Hung Transom](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/) | Wood | 0.18 | 0.11 | 2,658 |
| [**Marvin** — Ultimate Glider](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-glider-413611/) | Wood | 0.18 | 0.11 | 9,660 |
| [**Sierra Pacific Windows** — H3 2.0 Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-h3-2-0-direct-set-414082/) | Wood | 0.18 | 0.11 | 1,846 |
| [**JELD-WEN, inc.** — Custom Clad Direct Set Geometric](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-custom-clad-direct-set-geometric-413361/) | Wood | 0.18 | 0.13 | 1,453 |

## What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [100 Series/Series 2 Fixed/Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/)

U-Factor 0.14–0.32 · 13,810 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/)

Picture WindowMin U 0.14

### [Complementary Wood Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

U-Factor 0.14–0.32 · 7,588 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

Picture WindowMin U 0.15

### [200 Series/400 Series Complementary Clad Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

U-Factor 0.15–0.32 · 12,778 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

Picture WindowMin U 0.15

### [400 Series Tilt-Wash Double-Hung Transom Full-Frame Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

U-Factor 0.15–0.32 · 2,446 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

Picture WindowMin U 0.15

### [E-Series Specialty (Auxiliary) Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

U-Factor 0.15–0.32 · 16,775 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

SideliteMin U 0.15

### [Renewal by Andersen® Entry Door – Panel Set Sidelight](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

U-Factor 0.15–0.28 · 24,853 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Picture Window appear below.

### Where does Andersen Corporation A-Series Picture Window stand thermally among ENERGY STAR Window lines?

Across 5,913 tested NFRC glazing configurations, Andersen Corporation A-Series Picture Window with Wood framing and Fixed Window (FIXD) style reaches a 0.18 minimum U-Factor and 0.12-0.47 SHGC band. It places #477 among 1,352 Window series—top 41.6%.

### Does Andersen Corporation A-Series Picture Window qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 366 A-Series Picture Window packages (U floor 0.18, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### What BTU/hr heat transfer results from A-Series Picture Window's 0.18 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Who should NOT choose Andersen Corporation A-Series Picture Window for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Picture Window options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### What Southern ENERGY STAR v7.0 options exist in A-Series Picture Window?

Yes. 5,291 Southern-certified options inside Andersen Corporation A-Series Picture Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.47 SHGC on west-facing glass to avoid excess afternoon solar gain.

### How many Andersen Corporation A-Series Picture Window variants earn ENERGY STAR Most Efficient?

Within A-Series Picture Window, 3.6% (212 of 5,913) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### Can homeowners claim Form 5695 credits on Andersen Corporation A-Series Picture Window in 2026?

Any A-Series Picture Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do building inspectors verify A-Series Picture Window glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-88 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
