---
title: "Andersen E-Series Hinged Patio Door - Inswing Specs"
url: https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-hinged-patio-door-inswing-412989/
description: "Andersen E-Series Hinged Patio Door - Inswing (AND-N-165, Swinging Entry Door (Double), Wood): U-Factor 0.23-0.28, SHGC 0.07-0.38, 2534 options across 4."
---

Door · Wood Frame NFRC AND · Product Line AND-N-165

# Andersen Corporation — E-Series Hinged Patio Door - Inswing · Swinging Entry Door (Double)

EPA ENERGY STAR Version 7.0 certifies 2,534 variants inside Andersen Corporation E-Series Hinged Patio Door - Inswing, combining Wood frame construction with U-Factors spanning 0.23 to 0.28 and SHGC 0.07 to 0.38. Qualifying for Northern, North-Central, South-Central, Southern, this Swinging Entry Door, Double family places #162 of 268 among 268 Door families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.07-0.38

- **Certified Options** : 2,534

- **Category Standing** : #162 of 268

## How does Andersen Corporation E-Series Hinged Patio Door - Inswing compare thermally against Door peers?

Andersen Corporation E-Series Hinged Patio Door - Inswing achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), E-Series Hinged Patio Door - Inswing reaches 0.23 on its lowest-conductivity package — #246 of 408 in Wood, tied with 33 others at 0.23, more insulating than 31.6% of Wood lines (+0.02 vs Wood peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.28 down toward 0.23.

Climate coverage for Andersen Corporation E-Series Hinged Patio Door - Inswing spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 451 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-04-11 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,534 certified glazing combinations for E-Series Hinged Patio Door - Inswing (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 451 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 451 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 2,454 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 2,454 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Sierra Pacific Windows** — Clad Outswing Door](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-outswing-door-414071/) | Wood | 0.23 | 0.06 | 1,159 |
| [**Weather Shield Mfg., Inc.** — 8622 Premium / 8623 Contemporary Bi-Fold Door](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8622-premium-8623-contemporary-bi-fold-door-4/) | Wood | 0.23 | 0.10 | 1,008 |
| [**JELD-WEN, inc.** — Siteline Clad Swinging Door](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-clad-swinging-door-413377/) | Wood | 0.23 | 0.11 | 971 |
| [**JELD-WEN, inc.** — Siteline Clad Wood Low Friction Gliding Door](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-clad-wood-low-friction-gliding-door-413388/) | Wood | 0.23 | 0.16 | 194 |
| [**JELD-WEN, inc.** — Custom Clad HGD Outswing Door](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-custom-clad-hgd-outswing-door-413340/) | Wood | 0.23 | 0.14 | 146 |

## What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [100 Series/Series 2 Fixed/Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/)

U-Factor 0.14–0.32 · 13,810 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-windows-412/)

Picture WindowMin U 0.14

### [Complementary Wood Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

U-Factor 0.14–0.32 · 7,588 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/)

Picture WindowMin U 0.15

### [200 Series/400 Series Complementary Clad Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

U-Factor 0.15–0.32 · 12,778 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-400-series-complementary-clad-specia/)

Picture WindowMin U 0.15

### [400 Series Tilt-Wash Double-Hung Transom Full-Frame Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

U-Factor 0.15–0.32 · 2,446 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/)

Picture WindowMin U 0.15

### [E-Series Specialty (Auxiliary) Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

U-Factor 0.15–0.32 · 16,775 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-specialty-auxiliary-window-412986/)

SideliteMin U 0.15

### [Renewal by Andersen® Entry Door – Panel Set Sidelight](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

U-Factor 0.15–0.28 · 24,853 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-renewal-by-andersen-entry-door-panel-set-sideli/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Hinged Patio Door - Inswing appear below.

### How well does E-Series Hinged Patio Door - Inswing by Andersen Corporation insulate relative to Door benchmarks?

Testing puts Andersen Corporation E-Series Hinged Patio Door - Inswing at rank #162 of 268 Door entries with U 0.23 to 0.28 across 2,534 configurations. Solar heat gain ranges between 0.07 and 0.38 across Northern, North-Central, South-Central, Southern.

### Can homeowners install E-Series Hinged Patio Door - Inswing in cold Northern ENERGY STAR counties?

Prescriptive Northern approval ends at U <= 0.22, above E-Series Hinged Patio Door - Inswing's 0.23 minimum. However, 451 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

### How does a 3x5 ft E-Series Hinged Patio Door - Inswing window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), E-Series Hinged Patio Door - Inswing at U 0.23 conducts 138.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### When should a buyer skip Andersen Corporation E-Series Hinged Patio Door - Inswing and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Hinged Patio Door - Inswing options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Can you install Andersen Corporation E-Series Hinged Patio Door - Inswing in Southern or South-Central zones?

Yes, E-Series Hinged Patio Door - Inswing holds 2,454 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.07 SHGC in cooling climates.

### Are all 2,534 E-Series Hinged Patio Door - Inswing configurations ENERGY STAR Most Efficient?

All 2,534 E-Series Hinged Patio Door - Inswing listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### Can homeowners claim Form 5695 credits on Andersen Corporation E-Series Hinged Patio Door - Inswing in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 E-Series Hinged Patio Door - Inswing installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### Where are NFRC and IGCC identification marks located on E-Series Hinged Patio Door - Inswing?

Match the NFRC thermal sticker for code AND and line AND-N-165 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Hinged Patio Door - Inswing come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
