title: "Anlin Industries Catalina/Del Mar/Extreme Horizontal"
url: https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-del-mar-extreme-horizontal-sliding-window/
description: "Anlin Industries Catalina/Del Mar/Extreme Horizontal Sliding Window (ANL-A-3, Single Slider, Vinyl): U-Factor 0.23-0.32, SHGC 0.13-0.50, 259 options across."
---

Window · Vinyl Frame NFRC ANL · Product Line ANL-A-3

# Anlin Industries — Catalina/Del Mar/Extreme Horizontal Sliding Window · Single Slider

Across 14 Anlin Industries certified families, Catalina/Del Mar/Extreme Horizontal Sliding Window supplies 259 Single Slider configurations starting at 0.23 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.50 SHGC. Its thermal floor ranks #936 of 1,352 category entries—0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.13-0.50

- **Certified Options** : 259

- **Category Standing** : #936 of 1,352

## How does Anlin Industries Catalina/Del Mar/Extreme Horizontal Sliding Window compare thermally against Window peers?

Anlin Industries Catalina/Del Mar/Extreme Horizontal Sliding Window achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 14 certified Anlin Industries series, this Single Slider offers a 0.09 U-Factor adjustment span between 0.32 entry options and 0.23 top-performing glazing. Category standing is #936/1,352 (tied with 97 others at 0.23, more insulating than 23.6% of Window lines).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 16 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors ANL to 2026-09-08 certification (FENSTAR issued 2017-12-11). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 259 certified glazing combinations for Catalina/Del Mar/Extreme Horizontal Sliding Window (NFRC ANL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 16 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 56 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 148 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 231 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Thermo-Tech Windows** — 7100 Single Hung](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-7100-single-hung-414171/) | Vinyl | 0.23 | 0.17 | 257 |
| [**Silver Line Building Products** — 2050/2130/2250/2350 Picture Window](https://ela-ecolandscapingassn.org/windows/models/silver-line-building-products-2050-2130-2250-2350-picture-window-414/) | Vinyl | 0.23 | 0.20 | 242 |
| [**Thompson Creek Window Company** — 7800 Single Hung](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7800-single-hung-414145/) | Vinyl | 0.23 | 0.18 | 242 |
| [**Harvey Industries, Inc.** — Vinyl Hopper](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-vinyl-hopper-413293/) | Vinyl | 0.23 | 0.16 | 181 |
| [**United Window & Door Mfg., Inc.** — 3800 - 3900 Single Hung Vinyl Window](https://ela-ecolandscapingassn.org/windows/models/united-window-door-mfg-inc-3800-3900-single-hung-vinyl-window-414210/) | Vinyl | 0.23 | 0.18 | 156 |

## What other certified series does Anlin Industries produce?

Compare other active Anlin Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.21

### [Monte Verde Fixed](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-monte-verde-fixed-413035/)

U-Factor 0.21–0.32 · 296 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-monte-verde-fixed-413035/)

Picture WindowMin U 0.22

### [Coronado/Monte Verde/Bayview/Extreme Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-coronado-monte-verde-bayview-extreme-fixed-casement/)

U-Factor 0.22–0.32 · 462 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-coronado-monte-verde-bayview-extreme-fixed-casement/)

Single HungMin U 0.23

### [Catalina/Del Mar/Extreme Single Hung Window](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-del-mar-extreme-single-hung-window-413028/)

U-Factor 0.23–0.32 · 259 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-del-mar-extreme-single-hung-window-413028/)

Single SliderMin U 0.23

### [Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-e-del-mar-e-bayview-panoramic-extreme-e-ho/)

U-Factor 0.23–0.32 · 230 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-e-del-mar-e-bayview-panoramic-extreme-e-ho/)

Single HungMin U 0.23

### [Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-e-del-mar-e-bayview-panoramic-extreme-e-si/)

U-Factor 0.23–0.32 · 230 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-e-del-mar-e-bayview-panoramic-extreme-e-si/)

Double HungMin U 0.24

### [Coronado Double Hung](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-coronado-double-hung-413029/)

U-Factor 0.24–0.32 · 321 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-coronado-double-hung-413029/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Anlin Industries Catalina/Del Mar/Extreme Horizontal Sliding Window appear below.

### What U-Factor and SHGC range does Anlin Industries Catalina/Del Mar/Extreme Horizontal Sliding Window achieve?

Testing puts Anlin Industries Catalina/Del Mar/Extreme Horizontal Sliding Window at rank #936 of 1,352 Window entries with U 0.23 to 0.32 across 259 configurations. Solar heat gain ranges between 0.13 and 0.50 across Northern, North-Central, South-Central, Southern.

### Can homeowners install Catalina/Del Mar/Extreme Horizontal Sliding Window in cold Northern ENERGY STAR counties?

Northern qualification on Catalina/Del Mar/Extreme Horizontal Sliding Window relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 16 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

### What BTU/hr heat transfer results from Catalina/Del Mar/Extreme Horizontal Sliding Window's 0.23 minimum U-Factor?

Using NFRC ANL U-Factor 0.23, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

### Who should NOT choose Anlin Industries Catalina/Del Mar/Extreme Horizontal Sliding Window for a residential project?

Do not specify Catalina/Del Mar/Extreme Horizontal Sliding Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Catalina/Del Mar/Extreme Horizontal Sliding Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does Catalina/Del Mar/Extreme Horizontal Sliding Window meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 231 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Anlin Industries Catalina/Del Mar/Extreme Horizontal Sliding Window, while total line SHGC reaches 0.50 in colder packages.

### What glazing share inside Catalina/Del Mar/Extreme Horizontal Sliding Window qualifies as Most Efficient?

All 259 Catalina/Del Mar/Extreme Horizontal Sliding Window listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### What federal compliance checks govern 2026 Catalina/Del Mar/Extreme Horizontal Sliding Window window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Catalina/Del Mar/Extreme Horizontal Sliding Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### What permanent glass etch marks verify Catalina/Del Mar/Extreme Horizontal Sliding Window after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code ANL and product line ANL-A-3, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Anlin Industries Catalina/Del Mar/Extreme Horizontal Sliding Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)