title: "Anlin Industries Monte Verde Horizontal Sliding Specs"
url: https://ela-ecolandscapingassn.org/windows/models/anlin-industries-monte-verde-horizontal-sliding-413037/
description: "Anlin Industries Monte Verde Horizontal Sliding (ANL-A-17, Single Slider, Vinyl): U-Factor 0.25-0.32, SHGC 0.13-0.50, 173 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC ANL · Product Line ANL-A-17

# Anlin Industries — Monte Verde Horizontal Sliding · Single Slider

EPA ENERGY STAR Version 7.0 certifies 173 variants inside Anlin Industries Monte Verde Horizontal Sliding, combining Vinyl frame construction with U-Factors spanning 0.25 to 0.32 and SHGC 0.13 to 0.50. Qualifying for Northern, North-Central, South-Central, Southern, this Single Slider family places #1,174 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.25

- **SHGC Range** : 0.13-0.50

- **Certified Options** : 173

- **Category Standing** : #1,174 of 1,352

## How does Anlin Industries Monte Verde Horizontal Sliding compare thermally against Window peers?

Anlin Industries Monte Verde Horizontal Sliding achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Monte Verde Horizontal Sliding is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.25-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2017-12-11 licensing and 2023-12-19 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 173 certified glazing combinations for Monte Verde Horizontal Sliding (NFRC ANL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 4 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 6 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 80 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 169 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Custom Window Systems, Inc.** — PW-8300 Fixed](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-pw-8300-fixed-413140/) | Vinyl | 0.25 | 0.15 | 150 |
| [**Pella Corporation** — Pella Hurricane Shield Series FX-530 - Fixed](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-hurricane-shield-series-fx-530-fixed-413918/) | Vinyl | 0.25 | 0.15 | 150 |
| [**Burris Windows** — TectView AC Single Hung](https://ela-ecolandscapingassn.org/windows/models/burris-windows-tectview-ac-single-hung-413092/) | Vinyl | 0.25 | 0.12 | 135 |
| [**Custom Window Systems, Inc.** — PW-8150 Fixed](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-pw-8150-fixed-413143/) | Vinyl | 0.25 | 0.14 | 212 |
| [**Hometime Windows & Doors** — 1600 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/hometime-windows-doors-1600-horizontal-slider-413310/) | Vinyl | 0.25 | 0.13 | 119 |

## What other certified series does Anlin Industries produce?

Compare other active Anlin Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.21

### [Monte Verde Fixed](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-monte-verde-fixed-413035/)

U-Factor 0.21–0.32 · 296 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-monte-verde-fixed-413035/)

Picture WindowMin U 0.22

### [Coronado/Monte Verde/Bayview/Extreme Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-coronado-monte-verde-bayview-extreme-fixed-casement/)

U-Factor 0.22–0.32 · 462 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-coronado-monte-verde-bayview-extreme-fixed-casement/)

Single SliderMin U 0.23

### [Catalina/Del Mar/Extreme Horizontal Sliding Window](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-del-mar-extreme-horizontal-sliding-window/)

U-Factor 0.23–0.32 · 259 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-del-mar-extreme-horizontal-sliding-window/)

Single HungMin U 0.23

### [Catalina/Del Mar/Extreme Single Hung Window](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-del-mar-extreme-single-hung-window-413028/)

U-Factor 0.23–0.32 · 259 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-del-mar-extreme-single-hung-window-413028/)

Single SliderMin U 0.23

### [Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-e-del-mar-e-bayview-panoramic-extreme-e-ho/)

U-Factor 0.23–0.32 · 230 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-e-del-mar-e-bayview-panoramic-extreme-e-ho/)

Single HungMin U 0.23

### [Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-e-del-mar-e-bayview-panoramic-extreme-e-si/)

U-Factor 0.23–0.32 · 230 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-e-del-mar-e-bayview-panoramic-extreme-e-si/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Anlin Industries Monte Verde Horizontal Sliding appear below.

### Where does Anlin Industries Monte Verde Horizontal Sliding stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 173 configurations for Anlin Industries Monte Verde Horizontal Sliding covering Northern, North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Does Anlin Industries Monte Verde Horizontal Sliding qualify for the ENERGY STAR Northern Zone?

With a 0.25 minimum U-Factor, Anlin Industries Monte Verde Horizontal Sliding cannot satisfy prescriptive <= 0.22 Northern targets, yet 4 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

### How does a 3x5 ft Monte Verde Horizontal Sliding window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Monte Verde Horizontal Sliding at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What are the practical limitations of specifying Monte Verde Horizontal Sliding?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Monte Verde Horizontal Sliding options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Does Monte Verde Horizontal Sliding meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 169 Monte Verde Horizontal Sliding options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.13 rather than higher 0.50 glass.

### Are all 173 Monte Verde Horizontal Sliding configurations ENERGY STAR Most Efficient?

Zero glazing builds inside Monte Verde Horizontal Sliding's 173 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### What federal compliance checks govern 2026 Monte Verde Horizontal Sliding window swaps?

Any Monte Verde Horizontal Sliding purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### Where are NFRC and IGCC identification marks located on Monte Verde Horizontal Sliding?

Match the NFRC thermal sticker for code ANL and line ANL-A-17 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Anlin Industries Monte Verde Horizontal Sliding come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)