---
title: "Associated Materials 03A0 Single Hung Specs (U 0.16)"
url: https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-03a0-single-hung-413050/
description: "Associated Materials 03A0 Single Hung (ASO-A-92, Single Hung, Vinyl): U-Factor 0.16-0.32, SHGC 0.06-0.49, 245476 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC ASO · Product Line ASO-A-92 ENERGY STAR Most Efficient Eligible

# Associated Materials, Inc. — 03A0 Single Hung · Single Hung

Associated Materials, Inc. engineered the 03A0 Single Hung Single Hung line for Northern, North-Central, South-Central, Southern, certifying 245,476 glass-spacer combinations from 0.16 to 0.32 U-Factor and 0.06 to 0.49 SHGC. Relative to other Vinyl models tracked under NFRC ASO, its minimum U-Factor is 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.16

- **SHGC Range** : 0.06-0.49

- **Certified Options** : 245,476

- **Category Standing** : #250 of 1,352

## How does Associated Materials, Inc. 03A0 Single Hung compare thermally against Window peers?

Associated Materials, Inc. 03A0 Single Hung achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Associated Materials, Inc. 03A0 Single Hung at rank #250 of 1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.06-0.49 band.

Climate coverage for Associated Materials, Inc. 03A0 Single Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 66,683 configurations meet ENERGY STAR Most Efficient criteria while 61,174 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 96.0 BTU/hr (-27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-01-26.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 245,476 certified glazing combinations for 03A0 Single Hung (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 61,174 packages (21,238 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 159,989 packages (42,813 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 142,676 packages (32,874 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 188,517 packages (56,744 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Great Lakes Window, Inc.** — ComfortSmart Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/great-lakes-window-inc-comfortsmart-horizontal-slider-413274/) | Vinyl | 0.16 | 0.12 | 154,875 |
| [**MI Windows and Doors, LLC** — 1654/1654HP Polyvinyl Chloride (PVC) Double Hung Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1654-1654hp-polyvinyl-chloride-pvc-double-h/) | Vinyl | 0.16 | 0.07 | 29,542 |
| [**MI Windows and Doors, LLC** — 1656 Polyvinyl Chloride (PVC) Double Hung Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1656-polyvinyl-chloride-pvc-double-hung-win/) | Vinyl | 0.16 | 0.07 | 28,065 |
| [**MI Windows and Doors, LLC** — 1650 Polyvinyl Chloride (PVC) Double Hung Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1650-polyvinyl-chloride-pvc-double-hung-win/) | Vinyl | 0.16 | 0.06 | 22,753 |
| [**MI Windows and Doors, LLC** — 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-4300sp-polyvinyl-chloride-pvc-fixed-direct/) | Vinyl | 0.16 | 0.09 | 17,779 |

## What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.12

### [A280/A580/S280/S580/A390 Fixed](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a280-a580-s280-s580-a390-fixed-413060/)

U-Factor 0.12–0.32 · 12,249 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a280-a580-s280-s580-a390-fixed-413060/)

Picture WindowMin U 0.13

### [3004 Picture Window](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-3004-picture-window-413049/)

U-Factor 0.13–0.32 · 43,046 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-3004-picture-window-413049/)

Picture WindowMin U 0.13

### [A680 Fixed Sash](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a680-fixed-sash-413061/)

U-Factor 0.13–0.32 · 28,687 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a680-fixed-sash-413061/)

Picture WindowMin U 0.13

### [A780/A790/ S780 Picture](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a780-a790-s780-picture-413054/)

U-Factor 0.13–0.32 · 3,066 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a780-a790-s780-picture-413054/)

Picture WindowMin U 0.14

### [A171 Picture](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a171-picture-413073/)

U-Factor 0.14–0.32 · 12,246 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a171-picture-413073/)

Awning (Projected)Min U 0.14

### [A681/691 Awning](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a681-691-awning-413063/)

U-Factor 0.14–0.32 · 60,157 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a681-691-awning-413063/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. 03A0 Single Hung appear below.

### Where does Associated Materials, Inc. 03A0 Single Hung stand thermally among ENERGY STAR Window lines?

Across 245,476 tested NFRC glazing configurations, Associated Materials, Inc. 03A0 Single Hung with Vinyl framing and Single-Hung (VSSH) style reaches a 0.16 minimum U-Factor and 0.06-0.49 SHGC band. It places #250 among 1,352 Window series—top 26.7%.

### How does Associated Materials, Inc. 03A0 Single Hung satisfy Version 7.0 Northern criteria?

Yes, 61,174 packages satisfy Northern ENERGY STAR Version 7.0 rules in 03A0 Single Hung. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How do you calculate winter heat conduction for Associated Materials, Inc. 03A0 Single Hung?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 03A0 Single Hung at U 0.16 conducts 96.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What homeowner profiles are a poor match for Associated Materials, Inc. 03A0 Single Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 03A0 Single Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### What Southern ENERGY STAR v7.0 options exist in 03A0 Single Hung?

Exactly 188,517 03A0 Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.06 rather than higher 0.49 glass.

### Which package tier in 03A0 Single Hung holds Most Efficient recognition?

Only 66,683 options out of 245,476 (27.2%) meet tighter Most Efficient U-Factor and SHGC thresholds in Associated Materials, Inc. 03A0 Single Hung, usually requiring triple-pane or upgraded Low-E coatings.

### How do the 25C sunset and pre-1978 Lead RRP rules affect 03A0 Single Hung?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How can homeowners confirm delivered Associated Materials, Inc. 03A0 Single Hung units match permits?

Match the NFRC thermal sticker for code ASO and line ASO-A-92 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. 03A0 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
