title: "Associated Materials 1900/1920/1930 Single Hung Specs"
url: https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-1900-1920-1930-single-hung-413066/
description: "Associated Materials 1900/1920/1930 Single Hung (ASO-A-115, Single Hung, Vinyl): U-Factor 0.24-0.32, SHGC 0.09-0.51, 1868 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC ASO · Product Line ASO-A-115

# Associated Materials, Inc. — 1900/1920/1930 Single Hung · Single Hung

EPA ENERGY STAR Version 7.0 certifies 1,868 variants inside Associated Materials, Inc. 1900/1920/1930 Single Hung, combining Vinyl frame construction with U-Factors spanning 0.24 to 0.32 and SHGC 0.09 to 0.51. Qualifying for Northern, North-Central, South-Central, Southern, this Single Hung family places #1,034 of 1,352 among 1,352 Window families and posts 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.09-0.51

- **Certified Options** : 1,868

- **Category Standing** : #1,034 of 1,352

## How does Associated Materials, Inc. 1900/1920/1930 Single Hung compare thermally against Window peers?

Associated Materials, Inc. 1900/1920/1930 Single Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Associated Materials, Inc. 1900/1920/1930 Single Hung standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.

Climate coverage for Associated Materials, Inc. 1900/1920/1930 Single Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 64 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-01-19. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,868 certified glazing combinations for 1900/1920/1930 Single Hung (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 64 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 250 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 459 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 1,684 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Wincore Window Company, LLC** — 400 500 Series Vinyl Fixed Window Sidelite](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-400-500-series-vinyl-fixed-window-sidelit/) | Vinyl | 0.24 | 0.06 | 1,835 |
| [**Interstate Building Materials, Inc.** — 145/5000/5100/5200 Single Slider](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-145-5000-5100-5200-single-slider-4/) | Vinyl | 0.24 | 0.18 | 1,800 |
| [**Interstate Building Materials, Inc.** — 145/5000/5100/5200 Single Hung](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-145-5000-5100-5200-single-hung-413/) | Vinyl | 0.24 | 0.18 | 1,798 |
| [**Interstate Building Materials, Inc.** — 145/5000/5100/5200 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-145-5000-5100-5200-horizontal-slid/) | Vinyl | 0.24 | 0.17 | 2,410 |
| [**Windsor Windows and Doors** — Next Dimension Narrow Sliding Patio Door Transom](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-narrow-sliding-patio-door-t/) | Vinyl | 0.24 | 0.11 | 1,274 |

## What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.12

### [A280/A580/S280/S580/A390 Fixed](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a280-a580-s280-s580-a390-fixed-413060/)

U-Factor 0.12–0.32 · 12,249 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a280-a580-s280-s580-a390-fixed-413060/)

Picture WindowMin U 0.13

### [3004 Picture Window](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-3004-picture-window-413049/)

U-Factor 0.13–0.32 · 43,046 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-3004-picture-window-413049/)

Picture WindowMin U 0.13

### [A680 Fixed Sash](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a680-fixed-sash-413061/)

U-Factor 0.13–0.32 · 28,687 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a680-fixed-sash-413061/)

Picture WindowMin U 0.13

### [A780/A790/ S780 Picture](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a780-a790-s780-picture-413054/)

U-Factor 0.13–0.32 · 3,066 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a780-a790-s780-picture-413054/)

Picture WindowMin U 0.14

### [A171 Picture](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a171-picture-413073/)

U-Factor 0.14–0.32 · 12,246 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a171-picture-413073/)

Awning (Projected)Min U 0.14

### [A681/691 Awning](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a681-691-awning-413063/)

U-Factor 0.14–0.32 · 60,157 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a681-691-awning-413063/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. 1900/1920/1930 Single Hung appear below.

### How efficient is Associated Materials, Inc. 1900/1920/1930 Single Hung compared with peer Window models?

EPA ENERGY STAR v7.0 records 1,868 configurations for Associated Materials, Inc. 1900/1920/1930 Single Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### How does Associated Materials, Inc. 1900/1920/1930 Single Hung satisfy Version 7.0 Northern criteria?

While Associated Materials, Inc. 1900/1920/1930 Single Hung misses the <= 0.22 prescriptive mark (floor U 0.24), 64 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

### What conductive BTU/hr difference separates 1900/1920/1930 Single Hung from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 1900/1920/1930 Single Hung at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What homeowner profiles are a poor match for Associated Materials, Inc. 1900/1920/1930 Single Hung?

Skip 1900/1920/1930 Single Hung if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 1900/1920/1930 Single Hung options exceeding U 0.22.

### Is 1900/1920/1930 Single Hung suitable for sunbelt cooling-dominated homes?

Exactly 1,684 1900/1920/1930 Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.51 glass.

### How many Associated Materials, Inc. 1900/1920/1930 Single Hung variants earn ENERGY STAR Most Efficient?

All 1,868 1900/1920/1930 Single Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### How do the 25C sunset and pre-1978 Lead RRP rules affect 1900/1920/1930 Single Hung?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Associated Materials, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do building inspectors verify 1900/1920/1930 Single Hung glass specs on job sites?

Match the NFRC thermal sticker for code ASO and line ASO-A-115 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. 1900/1920/1930 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)