title: "Associated Materials A780/A790/ S780 Picture Specs"
url: https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a780-a790-s780-picture-413054/
description: "Associated Materials A780/A790/ S780 Picture (ASO-A-99, Picture Window, Vinyl): U-Factor 0.13-0.32, SHGC 0.07-0.56, 3066 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC ASO · Product Line ASO-A-99 ENERGY STAR Most Efficient Eligible

# Associated Materials, Inc. — A780/A790/ S780 Picture · Picture Window

Positioning #36/1,352 in certified Window, Associated Materials, Inc. A780/A790/ S780 Picture pairs Vinyl frame construction with 3,066 glazing options rated between 0.07 and 0.56 SHGC across Northern, North-Central, South-Central, Southern. Across 34 certified Associated Materials, Inc. product families, its thermal resistance spans 0.13 to 0.32 U-Factor and the line includes 909 ENERGY STAR Most Efficient packages (29.6% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.13

- **SHGC Range** : 0.07-0.56

- **Certified Options** : 3,066

- **Category Standing** : #36 of 1,352

## How does Associated Materials, Inc. A780/A790/ S780 Picture compare thermally against Window peers?

Associated Materials, Inc. A780/A790/ S780 Picture achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across A780/A790/ S780 Picture spans 3,066 NFRC test records (ASO), ranking #36 of 1,352 Window families (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%). Its 0.13 thermal floor compares at -0.06 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.07 to 0.56) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 909 configurations meet ENERGY STAR Most Efficient criteria while 973 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors ASO to 2025-09-29 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 78.0 BTU/hr conductive loss (-40.9% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,066 certified glazing combinations for A780/A790/ S780 Picture (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 973 packages (479 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,431 packages (698 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 1,564 packages (433 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,251 packages (594 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**EnergyWall Window** — 8605/3205 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/energywall-window-8605-3205-casement-picture-window-413230/) | Vinyl | 0.13 | 0.16 | 3,472 |
| [**Polaris Windows and Doors** — 8605/3205 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-8605-3205-casement-picture-window-413939/) | Vinyl | 0.13 | 0.16 | 3,472 |
| [**Seaway Manufacturing Corporation** — Lighthouse/Commander Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-casement-fixed/) | Vinyl | 0.13 | 0.12 | 2,119 |
| [**Euroline Windows Inc.** — Energeto Neo-76 Picture Window](https://ela-ecolandscapingassn.org/windows/models/euroline-windows-inc-energeto-neo-76-picture-window-413023/) | Vinyl | 0.13 | 0.15 | 2,041 |
| [**Soft-Lite, LLC** — CPW Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-cpw-casement-picture-window-414111/) | Vinyl | 0.13 | 0.13 | 1,003 |

## What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.12

### [A280/A580/S280/S580/A390 Fixed](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a280-a580-s280-s580-a390-fixed-413060/)

U-Factor 0.12–0.32 · 12,249 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a280-a580-s280-s580-a390-fixed-413060/)

Picture WindowMin U 0.13

### [3004 Picture Window](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-3004-picture-window-413049/)

U-Factor 0.13–0.32 · 43,046 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-3004-picture-window-413049/)

Picture WindowMin U 0.13

### [A680 Fixed Sash](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a680-fixed-sash-413061/)

U-Factor 0.13–0.32 · 28,687 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a680-fixed-sash-413061/)

Picture WindowMin U 0.14

### [A171 Picture](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a171-picture-413073/)

U-Factor 0.14–0.32 · 12,246 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a171-picture-413073/)

Awning (Projected)Min U 0.14

### [A681/691 Awning](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a681-691-awning-413063/)

U-Factor 0.14–0.32 · 60,157 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a681-691-awning-413063/)

Casement WindowsMin U 0.14

### [A682/692 Casement](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a682-692-casement-413062/)

U-Factor 0.14–0.32 · 60,748 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a682-692-casement-413062/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. A780/A790/ S780 Picture appear below.

### How well does A780/A790/ S780 Picture by Associated Materials, Inc. insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 3,066 configurations for Associated Materials, Inc. A780/A790/ S780 Picture covering Northern, North-Central, South-Central, Southern, dropping down to U 0.13 versus a 0.20 Window median. Only 909 options earn Most Efficient status.

### Can homeowners install A780/A790/ S780 Picture in cold Northern ENERGY STAR counties?

Yes. 973 packages in Associated Materials, Inc. A780/A790/ S780 Picture clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

### What conductive BTU/hr difference separates A780/A790/ S780 Picture from the 0.22 Northern rule?

At U 0.13, a standard 3x5 ft (15 sq ft) A780/A790/ S780 Picture opening transfers 78.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -54.0 BTU/hr difference.

### When should a buyer skip Associated Materials, Inc. A780/A790/ S780 Picture and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on A780/A790/ S780 Picture options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### Can you install Associated Materials, Inc. A780/A790/ S780 Picture in Southern or South-Central zones?

Yes, A780/A790/ S780 Picture holds 2,251 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.07 SHGC in cooling climates.

### Are all 3,066 A780/A790/ S780 Picture configurations ENERGY STAR Most Efficient?

No. Exactly 909 of 3,066 configurations (29.6%) earn ENERGY STAR Most Efficient status in A780/A790/ S780 Picture; the remaining standard v7.0 options pass base zone limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect A780/A790/ S780 Picture?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### What permanent glass etch marks verify A780/A790/ S780 Picture after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code ASO and product line ASO-A-99, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. A780/A790/ S780 Picture come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)