title: "Atrium Companies 450/455/460/465 DH Specs (U 0.24)"
url: https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-450-455-460-465-dh-412876/
description: "Atrium Companies 450/455/460/465 DH (ADW-M-406, Double Hung, Vinyl): U-Factor 0.24-0.32, SHGC 0.15-0.47, 805 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC ADW · Product Line ADW-M-406

# Atrium Companies, Inc. — 450/455/460/465 DH · Double Hung

Across 10 Atrium Companies, Inc. certified families, 450/455/460/465 DH supplies 805 Double Hung configurations starting at 0.24 U-Factor and 0.15 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.47 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.15-0.47

- **Certified Options** : 805

- **Category Standing** : #1,034 of 1,352

## How does Atrium Companies, Inc. 450/455/460/465 DH compare thermally against Window peers?

Atrium Companies, Inc. 450/455/460/465 DH achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 450/455/460/465 DH reaches 0.24 on its lowest-conductivity package — #798 of 1,009 in Vinyl, tied with 108 others at 0.24, more insulating than 10.2% of Vinyl lines (+0.05 vs Vinyl peers). Pairing NFRC ID ADW across multi-pane fills shifts U-Factor from 0.32 down toward 0.24.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 40 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-01-09 and FENSTAR license 2018-10-03 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 805 certified glazing combinations for 450/455/460/465 DH (NFRC ADW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 40 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 96 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 356 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 743 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**YKK AP America, Inc.** — Style View Single Slider](https://ela-ecolandscapingassn.org/windows/models/ykk-ap-america-inc-style-view-single-slider-414480/) | Vinyl | 0.24 | 0.19 | 803 |
| [**Vinylmax LLC** — SH46 Single Slider](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-sh46-single-slider-414260/) | Vinyl | 0.24 | 0.19 | 753 |
| [**YKK AP America, Inc.** — Precedence Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/ykk-ap-america-inc-precedence-horizontal-slider-414484/) | Vinyl | 0.24 | 0.18 | 884 |
| [**Vinylmax LLC** — SH46 Single Hung](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-sh46-single-hung-414261/) | Vinyl | 0.24 | 0.19 | 690 |
| [**A Window, Inc.** — V-25/31 SS](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-25-31-ss-413082/) | Vinyl | 0.24 | 0.15 | 970 |

## What other certified series does Atrium Companies, Inc. produce?

Compare other active Atrium Companies, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [8900/90/8000/1800/8900 Picture Window](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8900-90-8000-1800-8900-picture-window-412873/)

U-Factor 0.15–0.31 · 312 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8900-90-8000-1800-8900-picture-window-412873/)

Double HungMin U 0.17

### [8900/3900/625/25 Double Hung](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8900-3900-625-25-double-hung-412871/)

U-Factor 0.17–0.32 · 474 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8900-3900-625-25-double-hung-412871/)

Double SliderMin U 0.17

### [8900/90/8000/1800/3900 Double Slider](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8900-90-8000-1800-3900-double-slider-412872/)

U-Factor 0.17–0.32 · 474 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8900-90-8000-1800-3900-double-slider-412872/)

Picture WindowMin U 0.21

### [315 Transom](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-315-transom-412874/)

U-Factor 0.21–0.32 · 1,115 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-315-transom-412874/)

Picture WindowMin U 0.21

### [450/455/460/465 PW](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-450-455-460-465-pw-412877/)

U-Factor 0.21–0.32 · 579 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-450-455-460-465-pw-412877/)

Picture WindowMin U 0.21

### [8300/8700/1300/1600/3201/3500/40/80/3000/6000 Picture Window](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8300-8700-1300-1600-3201-3500-40-80-3000-6000-p/)

U-Factor 0.21–0.31 · 1,710 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8300-8700-1300-1600-3201-3500-40-80-3000-6000-p/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Atrium Companies, Inc. 450/455/460/465 DH appear below.

### What U-Factor and SHGC range does Atrium Companies, Inc. 450/455/460/465 DH achieve?

EPA ENERGY STAR v7.0 records 805 configurations for Atrium Companies, Inc. 450/455/460/465 DH covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Does Atrium Companies, Inc. 450/455/460/465 DH qualify for the ENERGY STAR Northern Zone?

Because 450/455/460/465 DH starts at 0.24 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 40 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

### What BTU/hr heat transfer results from 450/455/460/465 DH's 0.24 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on 450/455/460/465 DH's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### Which situations make 450/455/460/465 DH the wrong window or door choice?

Skip 450/455/460/465 DH if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 450/455/460/465 DH options exceeding U 0.22.

### What Southern ENERGY STAR v7.0 options exist in 450/455/460/465 DH?

Across Northern, North-Central, South-Central, Southern, 743 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Atrium Companies, Inc. 450/455/460/465 DH, while total line SHGC reaches 0.47 in colder packages.

### Are all 805 450/455/460/465 DH configurations ENERGY STAR Most Efficient?

450/455/460/465 DH holds zero Most Efficient entries across its 805 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

### What 2026 federal tax credit and Lead RRP rules apply to 450/455/460/465 DH?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 450/455/460/465 DH installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### Where are NFRC and IGCC identification marks located on 450/455/460/465 DH?

Match the NFRC thermal sticker for code ADW and line ADW-M-406 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Atrium Companies, Inc. 450/455/460/465 DH come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)