title: "Atrium Companies 450/455/460/465 PW Specs (U 0.21)"
url: https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-450-455-460-465-pw-412877/
description: "Atrium Companies 450/455/460/465 PW (ADW-M-407, Picture Window, Vinyl): U-Factor 0.21-0.32, SHGC 0.16-0.51, 579 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC ADW · Product Line ADW-M-407 ENERGY STAR Most Efficient Eligible

# Atrium Companies, Inc. — 450/455/460/465 PW · Picture Window

Across 10 Atrium Companies, Inc. certified families, 450/455/460/465 PW supplies 579 Picture Window configurations starting at 0.21 U-Factor and 0.16 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.51 SHGC. Its thermal floor ranks #742 of 1,352 category entries—0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.16-0.51

- **Certified Options** : 579

- **Category Standing** : #742 of 1,352

## How does Atrium Companies, Inc. 450/455/460/465 PW compare thermally against Window peers?

Atrium Companies, Inc. 450/455/460/465 PW achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 450/455/460/465 PW is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.21-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 83 configurations meet ENERGY STAR Most Efficient criteria while 188 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-12-20 and FENSTAR license 2018-10-03 inside EPA Version 7.0 tables. Heat transfer computes to 126.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 579 certified glazing combinations for 450/455/460/465 PW (NFRC ADW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 188 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 366 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 282 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 369 packages (83 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Krestmark Industries L. P.** — 400/4000 PW](https://ela-ecolandscapingassn.org/windows/models/krestmark-industries-l-p-400-4000-pw-413504/) | Vinyl | 0.21 | 0.19 | 576 |
| [**A Window, Inc.** — SL3 Series Picture Window (16059 Frame)](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-sl3-series-picture-window-16059-frame-413088/) | Vinyl | 0.21 | 0.18 | 575 |
| [**A Window, Inc.** — V-25 PW](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-25-pw-413080/) | Vinyl | 0.21 | 0.16 | 627 |
| [**A Window, Inc.** — V-31 PW](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-31-pw-413085/) | Vinyl | 0.21 | 0.16 | 627 |
| [**Windsor Windows and Doors** — Next Dimension Signature Radius and Direct Set](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-signature-radius-and-direct/) | Vinyl | 0.21 | 0.13 | 518 |

## What other certified series does Atrium Companies, Inc. produce?

Compare other active Atrium Companies, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [8900/90/8000/1800/8900 Picture Window](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8900-90-8000-1800-8900-picture-window-412873/)

U-Factor 0.15–0.31 · 312 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8900-90-8000-1800-8900-picture-window-412873/)

Double HungMin U 0.17

### [8900/3900/625/25 Double Hung](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8900-3900-625-25-double-hung-412871/)

U-Factor 0.17–0.32 · 474 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8900-3900-625-25-double-hung-412871/)

Double SliderMin U 0.17

### [8900/90/8000/1800/3900 Double Slider](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8900-90-8000-1800-3900-double-slider-412872/)

U-Factor 0.17–0.32 · 474 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8900-90-8000-1800-3900-double-slider-412872/)

Picture WindowMin U 0.21

### [315 Transom](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-315-transom-412874/)

U-Factor 0.21–0.32 · 1,115 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-315-transom-412874/)

Picture WindowMin U 0.21

### [8300/8700/1300/1600/3201/3500/40/80/3000/6000 Picture Window](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8300-8700-1300-1600-3201-3500-40-80-3000-6000-p/)

U-Factor 0.21–0.31 · 1,710 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-8300-8700-1300-1600-3201-3500-40-80-3000-6000-p/)

Picture WindowMin U 0.23

### [316 Sidelite](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-316-sidelite-412875/)

U-Factor 0.23–0.32 · 905 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-316-sidelite-412875/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Atrium Companies, Inc. 450/455/460/465 PW appear below.

### What thermal performance numbers separate Atrium Companies, Inc. 450/455/460/465 PW from peers?

Atrium Companies, Inc. 450/455/460/465 PW spans 579 certified configurations with U-Factors between 0.21 and 0.32 and SHGC values from 0.16 to 0.51. Ranked #742 of 1,352 Window families, it carries 83 Most Efficient options.

### How does Atrium Companies, Inc. 450/455/460/465 PW satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 188 450/455/460/465 PW packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### What BTU/hr heat transfer results from 450/455/460/465 PW's 0.21 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 126.0 BTU/hr on 450/455/460/465 PW's lowest-U package (0.21), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### What are the practical limitations of specifying 450/455/460/465 PW?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 450/455/460/465 PW options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Is 450/455/460/465 PW suitable for sunbelt cooling-dominated homes?

Yes, 450/455/460/465 PW holds 369 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

### Which package tier in 450/455/460/465 PW holds Most Efficient recognition?

Within 450/455/460/465 PW, 14.3% (83 of 579) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### How do the 25C sunset and pre-1978 Lead RRP rules affect 450/455/460/465 PW?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Atrium Companies, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### What permanent glass etch marks verify 450/455/460/465 PW after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line ADW-M-407 and NFRC ID ADW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Atrium Companies, Inc. 450/455/460/465 PW come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)