title: "California Deluxe Windows Industries S-3000 Casement Specs"
url: https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3000-casement-413100/
description: "California Deluxe Windows Industries S-3000 Casement (CDW-A-18, Casement Windows, Vinyl): U-Factor 0.22-0.28, SHGC 0.11-0.18, 26 options across 4 ENERGY."
---

Window · Vinyl Frame NFRC CDW · Product Line CDW-A-18 ENERGY STAR Most Efficient Eligible

# California Deluxe Windows Industries, Inc. — S-3000 Casement · Casement Windows

With a minimum U-Factor of 0.22—+0.02 compared against the 0.20 Window median—California Deluxe Windows Industries, Inc. S-3000 Casement spans 26 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code CDW, the Vinyl assembly includes 6 ENERGY STAR Most Efficient packages (23.1% of line) and offers SHGC packages between 0.11 and 0.18.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.22

- **SHGC Range** : 0.11-0.18

- **Certified Options** : 26

- **Category Standing** : #831 of 1,352

## How does California Deluxe Windows Industries, Inc. S-3000 Casement compare thermally against Window peers?

California Deluxe Windows Industries, Inc. S-3000 Casement achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows California Deluxe Windows Industries, Inc. S-3000 Casement standing at #831 of 1,352 certified Window product series, tied with 104 others at 0.22, more insulating than 30.8% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.03 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.11 to 0.18) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 6 configurations meet ENERGY STAR Most Efficient criteria while 2 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-04-16 and FENSTAR license 2023-05-31 inside EPA Version 7.0 tables. Heat transfer computes to 132.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 26 certified glazing combinations for S-3000 Casement (NFRC CDW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 2 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 18 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 26 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 26 packages (6 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Hometime Windows & Doors** — 314 Casement](https://ela-ecolandscapingassn.org/windows/models/hometime-windows-doors-314-casement-413313/) | Vinyl | 0.22 | 0.12 | 26 |
| [**Vytex Corporation** — Fortis Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-fortis-horizontal-slider-414298/) | Vinyl | 0.22 | 0.17 | 33 |
| [**Regency Plus, Inc.** — 1590 Vinyl Fixed](https://ela-ecolandscapingassn.org/windows/models/regency-plus-inc-1590-vinyl-fixed-414017/) | Vinyl | 0.22 | 0.20 | 34 |
| [**Advent Windows and Doors** — Ascend Series PW](https://ela-ecolandscapingassn.org/windows/models/advent-windows-and-doors-ascend-series-pw-413077/) | Vinyl | 0.22 | 0.14 | 16 |
| [**Thermal-Gard Building Products, Inc.** — 505/555/605/655 Double Hung](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-505-555-605-655-double-hung-41416/) | Vinyl | 0.22 | 0.22 | 16 |

## What other certified series does California Deluxe Windows Industries, Inc. produce?

Compare other active California Deluxe Windows Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.21

### [S-3200 Fixed](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3200-fixed-413099/)

U-Factor 0.21–0.30 · 24 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3200-fixed-413099/)

Swinging Entry Door (Single)Min U 0.22

### [S-6300 Tilt & Turn Door (Inswing)](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-door-inswi/)

U-Factor 0.22–0.28 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-door-inswi/)

Dual Action (Tilt Turn)Min U 0.22

### [S-6300 Tilt & Turn Window](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-window-413/)

U-Factor 0.22–0.28 · 22 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-window-413/)

Single SliderMin U 0.23

### [S-3430 Single Slider](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3430-single-slider-413095/)

U-Factor 0.23–0.31 · 40 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3430-single-slider-413095/)

Single HungMin U 0.23

### [S-3480 Single Hung](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3480-single-hung-413096/)

U-Factor 0.23–0.31 · 28 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3480-single-hung-413096/)

Double HungMin U 0.23

### [S-3555 Double Hung](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3555-double-hung-413098/)

U-Factor 0.23–0.31 · 28 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3555-double-hung-413098/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to California Deluxe Windows Industries, Inc. S-3000 Casement appear below.

### What thermal performance numbers separate California Deluxe Windows Industries, Inc. S-3000 Casement from peers?

California Deluxe Windows Industries, Inc. S-3000 Casement spans 26 certified configurations with U-Factors between 0.22 and 0.28 and SHGC values from 0.11 to 0.18. Ranked #831 of 1,352 Window families, it carries 6 Most Efficient options.

### Is S-3000 Casement approved for Northern Zone heating climates?

Cold-climate buyers get 2 compliant Northern packages inside S-3000 Casement, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

### What BTU/hr heat transfer results from S-3000 Casement's 0.22 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 132.0 BTU/hr on S-3000 Casement's lowest-U package (0.22), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

### What are the practical limitations of specifying S-3000 Casement?

Do not specify S-3000 Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on S-3000 Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Is S-3000 Casement suitable for sunbelt cooling-dominated homes?

Exactly 26 S-3000 Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.11 rather than higher 0.18 glass.

### Are all 26 S-3000 Casement configurations ENERGY STAR Most Efficient?

EPA lists 6 Most Efficient options (23.1% share) inside California Deluxe Windows Industries, Inc. S-3000 Casement, out of 26 total Version 7.0 entries.

### Do 2026 S-3000 Casement installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 S-3000 Casement installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How can homeowners confirm delivered California Deluxe Windows Industries, Inc. S-3000 Casement units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code CDW and product line CDW-A-18, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for California Deluxe Windows Industries, Inc. S-3000 Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)