---
title: "California Deluxe Windows Industries S-3480 Single Hung"
url: https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3480-single-hung-413096/
description: "California Deluxe Windows Industries S-3480 Single Hung (CDW-A-14, Single Hung, Vinyl): U-Factor 0.23-0.31, SHGC 0.12-0.21, 28 options across 3 ENERGY STAR."
---

Window · Vinyl Frame NFRC CDW · Product Line CDW-A-14

# California Deluxe Windows Industries, Inc. — S-3480 Single Hung · Single Hung

EPA ENERGY STAR Version 7.0 certifies 28 variants inside California Deluxe Windows Industries, Inc. S-3480 Single Hung, combining Vinyl frame construction with U-Factors spanning 0.23 to 0.31 and SHGC 0.12 to 0.21. Qualifying for North-Central, South-Central, Southern, this Single Hung family places #936 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.12-0.21

- **Certified Options** : 28

- **Category Standing** : #936 of 1,352

## How does California Deluxe Windows Industries, Inc. S-3480 Single Hung compare thermally against Window peers?

California Deluxe Windows Industries, Inc. S-3480 Single Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places California Deluxe Windows Industries, Inc. S-3480 Single Hung at rank #936 of 1,352 (tied with 97 others at 0.23, more insulating than 23.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.12-0.21 band.

Evaluating climate compliance across North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Lifecycle documentation anchors CDW to 2026-10-09 certification (FENSTAR issued 2023-05-31). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 28 certified glazing combinations for S-3480 Single Hung (NFRC CDW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 8 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 24 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 28 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Vytex Corporation** — Georgetown Elite Slider](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-georgetown-elite-slider-414304/) | Vinyl | 0.23 | 0.19 | 28 |
| [**Vytex Corporation** — Georgetown Elite Double Hung](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-georgetown-elite-double-hung-414305/) | Vinyl | 0.23 | 0.19 | 30 |
| [**Crystal Pacific Window** — Vista Plus Awning](https://ela-ecolandscapingassn.org/windows/models/crystal-pacific-window-vista-plus-awning-413115/) | Vinyl | 0.23 | 0.15 | 32 |
| [**Crystal Pacific Window** — Vista Plus Casement](https://ela-ecolandscapingassn.org/windows/models/crystal-pacific-window-vista-plus-casement-413114/) | Vinyl | 0.23 | 0.15 | 32 |
| [**Vinyl Kraft, Inc.** — Vinyl Kraft Hopper](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-vinyl-kraft-hopper-414230/) | Vinyl | 0.23 | 0.18 | 32 |

## What other certified series does California Deluxe Windows Industries, Inc. produce?

Compare other active California Deluxe Windows Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.21

### [S-3200 Fixed](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3200-fixed-413099/)

U-Factor 0.21–0.30 · 24 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3200-fixed-413099/)

Casement WindowsMin U 0.22

### [S-3000 Casement](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3000-casement-413100/)

U-Factor 0.22–0.28 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3000-casement-413100/)

Swinging Entry Door (Single)Min U 0.22

### [S-6300 Tilt & Turn Door (Inswing)](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-door-inswi/)

U-Factor 0.22–0.28 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-door-inswi/)

Dual Action (Tilt Turn)Min U 0.22

### [S-6300 Tilt & Turn Window](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-window-413/)

U-Factor 0.22–0.28 · 22 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-window-413/)

Single SliderMin U 0.23

### [S-3430 Single Slider](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3430-single-slider-413095/)

U-Factor 0.23–0.31 · 40 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3430-single-slider-413095/)

Double HungMin U 0.23

### [S-3555 Double Hung](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3555-double-hung-413098/)

U-Factor 0.23–0.31 · 28 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3555-double-hung-413098/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to California Deluxe Windows Industries, Inc. S-3480 Single Hung appear below.

### What thermal performance numbers separate California Deluxe Windows Industries, Inc. S-3480 Single Hung from peers?

EPA ENERGY STAR v7.0 records 28 configurations for California Deluxe Windows Industries, Inc. S-3480 Single Hung covering North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Does California Deluxe Windows Industries, Inc. S-3480 Single Hung qualify for the ENERGY STAR Northern Zone?

California Deluxe Windows Industries, Inc. S-3480 Single Hung holds zero Northern Zone qualifications (min U 0.23). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

### What BTU/hr heat transfer results from S-3480 Single Hung's 0.23 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 138.0 BTU/hr on S-3480 Single Hung's lowest-U package (0.23), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.31 transfer proportionally more energy.

### Who should NOT choose California Deluxe Windows Industries, Inc. S-3480 Single Hung for a residential project?

Do not specify S-3480 Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on S-3480 Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### How many S-3480 Single Hung glazing packages pass Southern solar-heat rules?

Across North-Central, South-Central, Southern, 28 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside California Deluxe Windows Industries, Inc. S-3480 Single Hung, while total line SHGC reaches 0.21 in colder packages.

### How many California Deluxe Windows Industries, Inc. S-3480 Single Hung variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 28 S-3480 Single Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### What federal compliance checks govern 2026 S-3480 Single Hung window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current S-3480 Single Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do you cross-check NFRC CDW and product line CDW-A-14 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code CDW and product line CDW-A-14, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for California Deluxe Windows Industries, Inc. S-3480 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
