---
title: "California Deluxe Windows Industries S-3555 Double Hung"
url: https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3555-double-hung-413098/
description: "California Deluxe Windows Industries S-3555 Double Hung (CDW-A-16, Double Hung, Vinyl): U-Factor 0.23-0.31, SHGC 0.11-0.20, 28 options across 3 ENERGY STAR."
---

Window · Vinyl Frame NFRC CDW · Product Line CDW-A-16

# California Deluxe Windows Industries, Inc. — S-3555 Double Hung · Double Hung

Positioning #936/1,352 in certified Window, California Deluxe Windows Industries, Inc. S-3555 Double Hung pairs Vinyl frame construction with 28 glazing options rated between 0.11 and 0.20 SHGC across North-Central, South-Central, Southern. Across 10 certified California Deluxe Windows Industries, Inc. product families, its thermal resistance spans 0.23 to 0.31 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.11-0.20

- **Certified Options** : 28

- **Category Standing** : #936 of 1,352

## How does California Deluxe Windows Industries, Inc. S-3555 Double Hung compare thermally against Window peers?

California Deluxe Windows Industries, Inc. S-3555 Double Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across S-3555 Double Hung spans 28 NFRC test records (CDW), ranking #936 of 1,352 Window families (tied with 97 others at 0.23, more insulating than 23.6% of Window lines). Its 0.23 thermal floor compares at +0.04 against the Vinyl median (0.19).

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Data provenance links certification 2026-10-01 and FENSTAR license 2023-05-31 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 28 certified glazing combinations for S-3555 Double Hung (NFRC CDW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 8 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 24 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 28 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Vytex Corporation** — Georgetown Elite Slider](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-georgetown-elite-slider-414304/) | Vinyl | 0.23 | 0.19 | 28 |
| [**Vytex Corporation** — Georgetown Elite Double Hung](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-georgetown-elite-double-hung-414305/) | Vinyl | 0.23 | 0.19 | 30 |
| [**Crystal Pacific Window** — Vista Plus Awning](https://ela-ecolandscapingassn.org/windows/models/crystal-pacific-window-vista-plus-awning-413115/) | Vinyl | 0.23 | 0.15 | 32 |
| [**Crystal Pacific Window** — Vista Plus Casement](https://ela-ecolandscapingassn.org/windows/models/crystal-pacific-window-vista-plus-casement-413114/) | Vinyl | 0.23 | 0.15 | 32 |
| [**Vinyl Kraft, Inc.** — Vinyl Kraft Hopper](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-vinyl-kraft-hopper-414230/) | Vinyl | 0.23 | 0.18 | 32 |

## What other certified series does California Deluxe Windows Industries, Inc. produce?

Compare other active California Deluxe Windows Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.21

### [S-3200 Fixed](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3200-fixed-413099/)

U-Factor 0.21–0.30 · 24 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3200-fixed-413099/)

Casement WindowsMin U 0.22

### [S-3000 Casement](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3000-casement-413100/)

U-Factor 0.22–0.28 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3000-casement-413100/)

Swinging Entry Door (Single)Min U 0.22

### [S-6300 Tilt & Turn Door (Inswing)](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-door-inswi/)

U-Factor 0.22–0.28 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-door-inswi/)

Dual Action (Tilt Turn)Min U 0.22

### [S-6300 Tilt & Turn Window](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-window-413/)

U-Factor 0.22–0.28 · 22 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-window-413/)

Single SliderMin U 0.23

### [S-3430 Single Slider](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3430-single-slider-413095/)

U-Factor 0.23–0.31 · 40 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3430-single-slider-413095/)

Single HungMin U 0.23

### [S-3480 Single Hung](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3480-single-hung-413096/)

U-Factor 0.23–0.31 · 28 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3480-single-hung-413096/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to California Deluxe Windows Industries, Inc. S-3555 Double Hung appear below.

### What U-Factor and SHGC range does California Deluxe Windows Industries, Inc. S-3555 Double Hung achieve?

Built with Vinyl framing in Double-Hung (VSDH) style, California Deluxe Windows Industries, Inc. S-3555 Double Hung offers 28 Version 7.0 configurations from U 0.23 up to 0.31, posting +0.03 against the Window median of 0.20 with 0 Most Efficient picks.

### Does California Deluxe Windows Industries, Inc. S-3555 Double Hung qualify for the ENERGY STAR Northern Zone?

No—with 0 Northern packages and a 0.23 thermal floor, California Deluxe Windows Industries, Inc. S-3555 Double Hung targets warmer North-Central, South-Central, Southern climates instead of cold Northern installations.

### How does a 3x5 ft S-3555 Double Hung window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### When should a buyer skip California Deluxe Windows Industries, Inc. S-3555 Double Hung and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on S-3555 Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Does S-3555 Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 28 Southern-approved options within S-3555 Double Hung spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Which package tier in S-3555 Double Hung holds Most Efficient recognition?

All 28 S-3555 Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### Do 2026 S-3555 Double Hung installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current S-3555 Double Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do you cross-check NFRC CDW and product line CDW-A-16 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line CDW-A-16 and NFRC ID CDW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for California Deluxe Windows Industries, Inc. S-3555 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
