title: "California Deluxe Windows Industries S-3725/3735 Single"
url: https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3725-3735-single-slider-4/
description: "California Deluxe Windows Industries S-3725/3735 Single Slider (CDW-A-21, Single Slider, Vinyl): U-Factor 0.24-0.32, SHGC 0.12-0.21, 40 options across 3."
---

Window · Vinyl Frame NFRC CDW · Product Line CDW-A-21

# California Deluxe Windows Industries, Inc. — S-3725/3735 Single Slider · Single Slider

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—California Deluxe Windows Industries, Inc. S-3725/3735 Single Slider spans 40 tested options across North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code CDW, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.12 and 0.21.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.12-0.21

- **Certified Options** : 40

- **Category Standing** : #1,034 of 1,352

## How does California Deluxe Windows Industries, Inc. S-3725/3735 Single Slider compare thermally against Window peers?

California Deluxe Windows Industries, Inc. S-3725/3735 Single Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows California Deluxe Windows Industries, Inc. S-3725/3735 Single Slider standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.

Evaluating climate compliance across North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2023-05-31 and v7.0 data certification on 2026-03-25. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 40 certified glazing combinations for S-3725/3735 Single Slider (NFRC CDW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 14 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 34 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 40 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Comfort View Products, LLC** — 1901 Picture Window](https://ela-ecolandscapingassn.org/windows/models/comfort-view-products-llc-1901-picture-window-413126/) | Vinyl | 0.24 | 0.21 | 40 |
| [**Target Windows and Doors** — SL 3000 Single Hung](https://ela-ecolandscapingassn.org/windows/models/target-windows-and-doors-sl-3000-single-hung-414142/) | Vinyl | 0.24 | 0.20 | 42 |
| [**Target Windows and Doors** — SL 3050 Single Slider](https://ela-ecolandscapingassn.org/windows/models/target-windows-and-doors-sl-3050-single-slider-414143/) | Vinyl | 0.24 | 0.20 | 42 |
| [**L.A.S. Enterprises** — Weathergard II - Vinyl Casement](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-casement-413521/) | Vinyl | 0.24 | 0.13 | 44 |
| [**L.A.S. Enterprises** — Weathergard II - Vinyl Picture](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-picture-413524/) | Vinyl | 0.24 | 0.14 | 44 |

## What other certified series does California Deluxe Windows Industries, Inc. produce?

Compare other active California Deluxe Windows Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.21

### [S-3200 Fixed](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3200-fixed-413099/)

U-Factor 0.21–0.30 · 24 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3200-fixed-413099/)

Casement WindowsMin U 0.22

### [S-3000 Casement](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3000-casement-413100/)

U-Factor 0.22–0.28 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3000-casement-413100/)

Swinging Entry Door (Single)Min U 0.22

### [S-6300 Tilt & Turn Door (Inswing)](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-door-inswi/)

U-Factor 0.22–0.28 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-door-inswi/)

Dual Action (Tilt Turn)Min U 0.22

### [S-6300 Tilt & Turn Window](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-window-413/)

U-Factor 0.22–0.28 · 22 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-window-413/)

Single SliderMin U 0.23

### [S-3430 Single Slider](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3430-single-slider-413095/)

U-Factor 0.23–0.31 · 40 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3430-single-slider-413095/)

Single HungMin U 0.23

### [S-3480 Single Hung](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3480-single-hung-413096/)

U-Factor 0.23–0.31 · 28 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3480-single-hung-413096/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to California Deluxe Windows Industries, Inc. S-3725/3735 Single Slider appear below.

### What thermal performance numbers separate California Deluxe Windows Industries, Inc. S-3725/3735 Single Slider from peers?

Across 40 tested NFRC glazing configurations, California Deluxe Windows Industries, Inc. S-3725/3735 Single Slider with Vinyl framing and Horizontal Slider (HSOX) style reaches a 0.24 minimum U-Factor and 0.12-0.21 SHGC band. It places #1,034 among 1,352 Window series—more insulating than 13.2%.

### Which glazing options in California Deluxe Windows Industries, Inc. S-3725/3735 Single Slider meet Northern climate limits?

California Deluxe Windows Industries, Inc. S-3725/3735 Single Slider holds zero Northern Zone qualifications (min U 0.24). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

### How much winter heat loss does S-3725/3735 Single Slider conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), S-3725/3735 Single Slider at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What homeowner profiles are a poor match for California Deluxe Windows Industries, Inc. S-3725/3735 Single Slider?

Do not specify S-3725/3735 Single Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on S-3725/3735 Single Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### How many S-3725/3735 Single Slider glazing packages pass Southern solar-heat rules?

Yes, S-3725/3735 Single Slider holds 40 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.12 SHGC in cooling climates.

### Which package tier in S-3725/3735 Single Slider holds Most Efficient recognition?

S-3725/3735 Single Slider holds zero Most Efficient entries across its 40 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

### How do the 25C sunset and pre-1978 Lead RRP rules affect S-3725/3735 Single Slider?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### What permanent glass etch marks verify S-3725/3735 Single Slider after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.24-0.32, SHGC 0.12-0.21) against permit drawings for line CDW-A-21. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for California Deluxe Windows Industries, Inc. S-3725/3735 Single Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)