---
title: "Cascadia Windows Universal Series Outswing Awning Window"
url: https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-outswing-awning-window-413131/
description: "Cascadia Windows Universal Series Outswing Awning Window (CWL-K-22, Awning (Projected), Fiberglass): U-Factor 0.12-0.28, SHGC 0.05-0.37, 600 options across."
---

Window · Fiberglass Frame NFRC CWL · Product Line CWL-K-22 ENERGY STAR Most Efficient Eligible

# Cascadia Windows Ltd. — Universal Series Outswing Awning Window · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 600 variants inside Cascadia Windows Ltd. Universal Series Outswing Awning Window, combining Fiberglass frame construction with U-Factors spanning 0.12 to 0.28 and SHGC 0.05 to 0.37. Qualifying for Northern, North-Central, South-Central, Southern, this Awning, Projected family places #19 of 1,352 among 1,352 Window families and posts 0.07 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Fiberglass peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.12

- **SHGC Range** : 0.05-0.37

- **Certified Options** : 600

- **Category Standing** : #19 of 1,352

## How does Cascadia Windows Ltd. Universal Series Outswing Awning Window compare thermally against Window peers?

Cascadia Windows Ltd. Universal Series Outswing Awning Window achieves a 0.12 thermal floor across Window lines, placing #19 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Universal Series Outswing Awning Window is 0.08 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Fiberglass frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.12-0.28.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 289 configurations meet ENERGY STAR Most Efficient criteria while 110 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors CWL to 2024-02-28 certification (FENSTAR issued 2018-01-12). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 72.0 BTU/hr conductive loss (-45.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 600 certified glazing combinations for Universal Series Outswing Awning Window (NFRC CWL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 110 packages (47 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 508 packages (265 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 543 packages (230 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 543 packages (254 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.12 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Fibertec Window and Door Group** — 300 Fixed Window](https://ela-ecolandscapingassn.org/windows/models/fibertec-window-and-door-group-300-fixed-window-413246/) | Fiberglass | 0.12 | 0.16 | 66 |
| [**Paradigm Window Solutions** — 8361 Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8361-fixed-casement-413977/) | Vinyl | 0.12 | 0.15 | 648 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Heritage Push Out Casement Picture](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-push-out-casement-picture-4/) | Wood | 0.12 | 0.09 | 928 |
| [**Euroline Windows Inc.** — Energeto Neo 76 Small Picture Window](https://ela-ecolandscapingassn.org/windows/models/euroline-windows-inc-energeto-neo-76-small-picture-window-413022/) | Vinyl | 0.12 | 0.16 | 1,028 |
| [**Slocomb Windows and Doors, Inc** — 400/500 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-picture-window-414097/) | Vinyl | 0.12 | 0.15 | 157 |

## What other certified series does Cascadia Windows Ltd. produce?

Compare other active Cascadia Windows Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.07

### [Universal Series Fixed Window Exterior Glazed](https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-fixed-window-exterior-glazed-4/)

U-Factor 0.07–0.29 · 545 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-fixed-window-exterior-glazed-4/)

Picture WindowMin U 0.07

### [Universal Series Fixed Window Interior Glazed](https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-fixed-window-interior-glazed-4/)

U-Factor 0.07–0.29 · 406 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-fixed-window-interior-glazed-4/)

Sliding Patio DoorMin U 0.08

### [Universal Series Tilt Slide Door](https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-tilt-slide-door-413137/)

U-Factor 0.08–0.27 · 579 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-tilt-slide-door-413137/)

Swinging Entry Door (Single)Min U 0.09

### [Universal Series Inswing / Outswing Door (Single)](https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-inswing-outswing-door-single-4/)

U-Factor 0.09–0.27 · 1,353 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-inswing-outswing-door-single-4/)

Dual Action (Tilt Turn)Min U 0.09

### [Universal Series Inswing Tilt-Turn Window](https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-inswing-tilt-turn-window-41313/)

U-Factor 0.09–0.28 · 428 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-inswing-tilt-turn-window-41313/)

Awning (Projected)Min U 0.11

### [Universal Series Inswing Hopper Window](https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-inswing-hopper-window-413133/)

U-Factor 0.11–0.28 · 438 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/cascadia-windows-ltd-universal-series-inswing-hopper-window-413133/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Cascadia Windows Ltd. Universal Series Outswing Awning Window appear below.

### What thermal performance numbers separate Cascadia Windows Ltd. Universal Series Outswing Awning Window from peers?

Testing puts Cascadia Windows Ltd. Universal Series Outswing Awning Window at rank #19 of 1,352 Window entries with U 0.12 to 0.28 across 600 configurations. Solar heat gain ranges between 0.05 and 0.37 across Northern, North-Central, South-Central, Southern.

### How does Cascadia Windows Ltd. Universal Series Outswing Awning Window satisfy Version 7.0 Northern criteria?

Yes, 110 packages satisfy Northern ENERGY STAR Version 7.0 rules in Universal Series Outswing Awning Window. Pairing multi-pane insulation down to 0.12 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How do you calculate winter heat conduction for Cascadia Windows Ltd. Universal Series Outswing Awning Window?

At U 0.12, a standard 3x5 ft (15 sq ft) Universal Series Outswing Awning Window opening transfers 72.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -60.0 BTU/hr difference.

### Which situations make Universal Series Outswing Awning Window the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Universal Series Outswing Awning Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### How many Universal Series Outswing Awning Window glazing packages pass Southern solar-heat rules?

Exactly 543 Universal Series Outswing Awning Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.05 rather than higher 0.37 glass.

### Which package tier in Universal Series Outswing Awning Window holds Most Efficient recognition?

No. Exactly 289 of 600 configurations (48.2%) earn ENERGY STAR Most Efficient status in Universal Series Outswing Awning Window; the remaining standard v7.0 options pass base zone limits only.

### Do 2026 Universal Series Outswing Awning Window installations qualify for IRS Section 25C tax credits?

Any Universal Series Outswing Awning Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How can homeowners confirm delivered Cascadia Windows Ltd. Universal Series Outswing Awning Window units match permits?

Verify NFRC ID CWL and series CWL-K-22 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Cascadia Windows Ltd. Universal Series Outswing Awning Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
