---
title: "Columbia Manufacturing Co. VSF Vinyl Self Flashing"
url: https://ela-ecolandscapingassn.org/windows/models/columbia-manufacturing-co-ltd-vsf-vinyl-self-flashing-skylight-41311/
description: "Columbia Manufacturing Co. VSF Vinyl Self Flashing Skylight (COL-M-3, Skylight, Aluminum): U-Factor 0.29-0.44, SHGC 0.14-0.26, 10 options across 4 ENERGY."
---

Skylight · Aluminum Frame NFRC COL · Product Line COL-M-3 ENERGY STAR Most Efficient Eligible

# Columbia Manufacturing Co., Ltd. — VSF Vinyl Self Flashing Skylight · Skylight

Across 3 Columbia Manufacturing Co., Ltd. certified families, VSF Vinyl Self Flashing Skylight supplies 10 Skylight configurations starting at 0.29 U-Factor and 0.14 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.44 U-Factor and 0.26 SHGC. Its thermal floor ranks #3 of 16 category entries—0.06 Btu/hr·ft²·°F more insulating than the 0.35 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.29

- **SHGC Range** : 0.14-0.26

- **Certified Options** : 10

- **Category Standing** : #3 of 16

## How does Columbia Manufacturing Co., Ltd. VSF Vinyl Self Flashing Skylight compare thermally against Skylight peers?

Columbia Manufacturing Co., Ltd. VSF Vinyl Self Flashing Skylight achieves a 0.29 thermal floor across Skylight lines, placing #3 of 16 against the 0.35 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 16 EPA-certified Skylight lines (category median: 0.35).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Skylight assemblies nationwide (median U 0.35), VSF Vinyl Self Flashing Skylight is 0.06 Btu/hr·ft²·°F more insulating than the 0.35 Btu/hr·ft²·°F median while keeping Aluminum frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.29-0.44.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.29 floor sits above the 0.22 prescriptive Northern ceiling, 10 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 174.0 BTU/hr (+31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-06-13 and cert timestamp 2024-12-20.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 10 certified glazing combinations for VSF Vinyl Self Flashing Skylight (NFRC COL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 10 packages (5 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 7 packages (1 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 7 packages (1 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 7 packages (1 Most Eff.) |

## Which competing Skylight series sit closest on U-Factor?

Inspect nearby Skylight competitors clustered closest to 0.29 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**CrystaLite, Inc.** — 5842 Fixed Skylight](https://ela-ecolandscapingassn.org/windows/models/crystalite-inc-5842-fixed-skylight-413123/) | Aluminum | 0.29 | 0.16 | 130 |
| [**CrystaLite, Inc.** — 5830 Venting Skylight](https://ela-ecolandscapingassn.org/windows/models/crystalite-inc-5830-venting-skylight-413122/) | Vinyl | 0.28 | 0.14 | 146 |
| [**VELUX** — FCM Fixed Curb Mounted Skylight](https://ela-ecolandscapingassn.org/windows/models/velux-fcm-fixed-curb-mounted-skylight-414243/) | Aluminum | 0.31 | 0.08 | 47 |
| [**VELUX** — TGF / TMF VELUX Sun Tunnel w/Flex Tube](https://ela-ecolandscapingassn.org/windows/models/velux-tgf-tmf-velux-sun-tunnel-w-flex-tube-414239/) | Aluminum | 0.26 | 0.22 | 4 |
| [**Columbia Manufacturing Co., Ltd.** — GL VCM-IF Skylight](https://ela-ecolandscapingassn.org/windows/models/columbia-manufacturing-co-ltd-gl-vcm-if-skylight-413111/) | Aluminum | 0.32 | 0.13 | 10 |

## What other certified series does Columbia Manufacturing Co., Ltd. produce?

Compare other active Columbia Manufacturing Co., Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

SkylightMin U 0.32

### [GL VCM-IF Skylight](https://ela-ecolandscapingassn.org/windows/models/columbia-manufacturing-co-ltd-gl-vcm-if-skylight-413111/)

U-Factor 0.32–0.48 · 10 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/columbia-manufacturing-co-ltd-gl-vcm-if-skylight-413111/)

SkylightMin U 0.32

### [GL VCM-OF Skylight](https://ela-ecolandscapingassn.org/windows/models/columbia-manufacturing-co-ltd-gl-vcm-of-skylight-413113/)

U-Factor 0.32–0.46 · 11 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/columbia-manufacturing-co-ltd-gl-vcm-of-skylight-413113/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Columbia Manufacturing Co., Ltd. VSF Vinyl Self Flashing Skylight appear below.

### What U-Factor and SHGC range does Columbia Manufacturing Co., Ltd. VSF Vinyl Self Flashing Skylight achieve?

Across 10 tested NFRC glazing configurations, Columbia Manufacturing Co., Ltd. VSF Vinyl Self Flashing Skylight with Aluminum framing and Fixed Skylight (SKFX) style reaches a 0.29 minimum U-Factor and 0.14-0.26 SHGC band. It places #3 among 16 Skylight series—top 25.0%.

### Does Columbia Manufacturing Co., Ltd. VSF Vinyl Self Flashing Skylight qualify for the ENERGY STAR Northern Zone?

Because VSF Vinyl Self Flashing Skylight starts at 0.29 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 10 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

### What conductive BTU/hr difference separates VSF Vinyl Self Flashing Skylight from the 0.22 Northern rule?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 174.0 BTU/hr on VSF Vinyl Self Flashing Skylight's lowest-U package (0.29), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.44 transfer proportionally more energy.

### What homeowner profiles are a poor match for Columbia Manufacturing Co., Ltd. VSF Vinyl Self Flashing Skylight?

Do not specify VSF Vinyl Self Flashing Skylight without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on VSF Vinyl Self Flashing Skylight options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does VSF Vinyl Self Flashing Skylight meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 7 Southern-certified options inside Columbia Manufacturing Co., Ltd. VSF Vinyl Self Flashing Skylight satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.26 SHGC on west-facing glass to avoid excess afternoon solar gain.

### How many Columbia Manufacturing Co., Ltd. VSF Vinyl Self Flashing Skylight variants earn ENERGY STAR Most Efficient?

EPA lists 5 Most Efficient options (50.0% share) inside Columbia Manufacturing Co., Ltd. VSF Vinyl Self Flashing Skylight, out of 10 total Version 7.0 entries.

### Can homeowners claim Form 5695 credits on Columbia Manufacturing Co., Ltd. VSF Vinyl Self Flashing Skylight in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do building inspectors verify VSF Vinyl Self Flashing Skylight glass specs on job sites?

Verify NFRC ID COL and series COL-M-3 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Columbia Manufacturing Co., Ltd. VSF Vinyl Self Flashing Skylight come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
