---
title: "CrystaLite 5842 Fixed Skylight Specs (U 0.29) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/crystalite-inc-5842-fixed-skylight-413123/
description: "CrystaLite 5842 Fixed Skylight (CRY-M-16, Skylight, Aluminum): U-Factor 0.29-0.41, SHGC 0.16-0.64, 130 options across 4 ENERGY STAR zones."
---

Skylight · Aluminum Frame NFRC CRY · Product Line CRY-M-16 ENERGY STAR Most Efficient Eligible

# CrystaLite, Inc. — 5842 Fixed Skylight · Skylight

EPA ENERGY STAR Version 7.0 certifies 130 variants inside CrystaLite, Inc. 5842 Fixed Skylight, combining Aluminum frame construction with U-Factors spanning 0.29 to 0.41 and SHGC 0.16 to 0.64. Qualifying for Northern, North-Central, South-Central, Southern, this Skylight family places #3 of 16 among 16 Skylight families and posts 0.06 Btu/hr·ft²·°F less insulating than the 0.23 Btu/hr·ft²·°F median among Aluminum peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.29

- **SHGC Range** : 0.16-0.64

- **Certified Options** : 130

- **Category Standing** : #3 of 16

## How does CrystaLite, Inc. 5842 Fixed Skylight compare thermally against Skylight peers?

CrystaLite, Inc. 5842 Fixed Skylight achieves a 0.29 thermal floor across Skylight lines, placing #3 of 16 against the 0.35 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 16 EPA-certified Skylight lines (category median: 0.35).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows CrystaLite, Inc. 5842 Fixed Skylight standing at #3 of 16 certified Skylight product series, tied with 1 other at 0.29, more insulating than 75.0% of Skylight lines, top 25.0%. Comparing Aluminum profiles alone (median 0.23) shows +0.06 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.16 to 0.64) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.29 floor sits above the 0.22 prescriptive Northern ceiling, 130 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-11-20 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 174.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 130 certified glazing combinations for 5842 Fixed Skylight (NFRC CRY) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 130 packages (126 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 26 packages (20 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 26 packages (20 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 26 packages (20 Most Eff.) |

## Which competing Skylight series sit closest on U-Factor?

Inspect nearby Skylight competitors clustered closest to 0.29 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Columbia Manufacturing Co., Ltd.** — VSF Vinyl Self Flashing Skylight](https://ela-ecolandscapingassn.org/windows/models/columbia-manufacturing-co-ltd-vsf-vinyl-self-flashing-skylight-41311/) | Aluminum | 0.29 | 0.14 | 10 |
| [**CrystaLite, Inc.** — 5830 Venting Skylight](https://ela-ecolandscapingassn.org/windows/models/crystalite-inc-5830-venting-skylight-413122/) | Vinyl | 0.28 | 0.14 | 146 |
| [**VELUX** — FCM Fixed Curb Mounted Skylight](https://ela-ecolandscapingassn.org/windows/models/velux-fcm-fixed-curb-mounted-skylight-414243/) | Aluminum | 0.31 | 0.08 | 47 |
| [**VELUX** — TGF / TMF VELUX Sun Tunnel w/Flex Tube](https://ela-ecolandscapingassn.org/windows/models/velux-tgf-tmf-velux-sun-tunnel-w-flex-tube-414239/) | Aluminum | 0.26 | 0.22 | 4 |
| [**Columbia Manufacturing Co., Ltd.** — GL VCM-OF Skylight](https://ela-ecolandscapingassn.org/windows/models/columbia-manufacturing-co-ltd-gl-vcm-of-skylight-413113/) | Aluminum | 0.32 | 0.14 | 11 |

## What other certified series does CrystaLite, Inc. produce?

Compare other active CrystaLite, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

SkylightMin U 0.28

### [5830 Venting Skylight](https://ela-ecolandscapingassn.org/windows/models/crystalite-inc-5830-venting-skylight-413122/)

U-Factor 0.28–0.43 · 146 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/crystalite-inc-5830-venting-skylight-413122/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to CrystaLite, Inc. 5842 Fixed Skylight appear below.

### What thermal performance numbers separate CrystaLite, Inc. 5842 Fixed Skylight from peers?

Testing puts CrystaLite, Inc. 5842 Fixed Skylight at rank #3 of 16 Skylight entries with U 0.29 to 0.41 across 130 configurations. Solar heat gain ranges between 0.16 and 0.64 across Northern, North-Central, South-Central, Southern.

### Which glazing options in CrystaLite, Inc. 5842 Fixed Skylight meet Northern climate limits?

While CrystaLite, Inc. 5842 Fixed Skylight misses the <= 0.22 prescriptive mark (floor U 0.29), 130 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

### How does a 3x5 ft 5842 Fixed Skylight window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 174.0 BTU/hr on 5842 Fixed Skylight's lowest-U package (0.29), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.41 transfer proportionally more energy.

### Which situations make 5842 Fixed Skylight the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 5842 Fixed Skylight options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### How many 5842 Fixed Skylight glazing packages pass Southern solar-heat rules?

Yes. 26 Southern-certified options inside CrystaLite, Inc. 5842 Fixed Skylight satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.64 SHGC on west-facing glass to avoid excess afternoon solar gain.

### How many CrystaLite, Inc. 5842 Fixed Skylight variants earn ENERGY STAR Most Efficient?

EPA lists 126 Most Efficient options (96.9% share) inside CrystaLite, Inc. 5842 Fixed Skylight, out of 130 total Version 7.0 entries.

### How do the 25C sunset and pre-1978 Lead RRP rules affect 5842 Fixed Skylight?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 5842 Fixed Skylight installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How do you cross-check NFRC CRY and product line CRY-M-16 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code CRY and product line CRY-M-16, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for CrystaLite, Inc. 5842 Fixed Skylight come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
