title: "Custom Window Systems SH-8100 Single Hung Specs (U 0.29)"
url: https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-sh-8100-single-hung-413141/
description: "Custom Window Systems SH-8100 Single Hung (CWS-K-11, Single Hung, Vinyl): U-Factor 0.29-0.32, SHGC 0.13-0.21, 157 options across 1 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC CWS · Product Line CWS-K-11

# Custom Window Systems, Inc. — SH-8100 Single Hung · Single Hung

With a minimum U-Factor of 0.29—+0.09 compared against the 0.20 Window median—Custom Window Systems, Inc. SH-8100 Single Hung spans 157 tested options across Southern up to 0.32 U-Factor. Carrying NFRC CPD code CWS, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.13 and 0.21.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.29

- **SHGC Range** : 0.13-0.21

- **Certified Options** : 157

- **Category Standing** : #1,344 of 1,352

## How does Custom Window Systems, Inc. SH-8100 Single Hung compare thermally against Window peers?

Custom Window Systems, Inc. SH-8100 Single Hung achieves a 0.29 thermal floor across Window lines, placing #1,344 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), SH-8100 Single Hung is 0.09 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.29-0.32.

Zone eligibility across EPA boundaries reaches 1 market (Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward Southern markets where low SHGC down to 0.13 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 174.0 BTU/hr (+31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-05 and cert timestamp 2026-05-04.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 157 certified glazing combinations for SH-8100 Single Hung (NFRC CWS) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Not Listed | <= 0.28 | <= 0.23 | 0 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 157 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.29 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Phos Window** — 1400 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/phos-window-1400-horizontal-slider-413075/) | Vinyl | 0.29 | 0.20 | 4 |
| [**Ram Industries Inc.** — S840 Heavy Picture Window](https://ela-ecolandscapingassn.org/windows/models/ram-industries-inc-s840-heavy-picture-window-414007/) | Aluminum | 0.29 | 0.14 | 57 |
| [**Andersen Corporation** — 100 Series/Series 2 Gliding Patio Door Transom](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-gliding-patio-door-transom/) | Composite | 0.29 | 0.12 | 716 |
| [**Value Windows & Doors** — Galaxy Single Slider](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-galaxy-single-slider-414275/) | Vinyl | 0.28 | 0.19 | 87 |
| [**ViWinTech Window** — 2100 Single Slider](https://ela-ecolandscapingassn.org/windows/models/viwintech-window-2100-single-slider-414268/) | Vinyl | 0.28 | 0.18 | 87 |

## What other certified series does Custom Window Systems, Inc. produce?

Compare other active Custom Window Systems, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.25

### [PW-8150 Fixed](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-pw-8150-fixed-413143/)

U-Factor 0.25–0.32 · 212 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-pw-8150-fixed-413143/)

Picture WindowMin U 0.25

### [PW-8300 Fixed](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-pw-8300-fixed-413140/)

U-Factor 0.25–0.32 · 150 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-pw-8300-fixed-413140/)

Picture WindowMin U 0.26

### [615/6150 Fixed](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-615-6150-fixed-413144/)

U-Factor 0.26–0.32 · 144 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-615-6150-fixed-413144/)

Awning (Projected)Min U 0.27

### [A-8450 Awning](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-a-8450-awning-413139/)

U-Factor 0.27–0.32 · 194 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-a-8450-awning-413139/)

Casement WindowsMin U 0.27

### [C-8400 Casement](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-c-8400-casement-413138/)

U-Factor 0.27–0.32 · 195 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-c-8400-casement-413138/)

Single SliderMin U 0.30

### [HS-8200 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-hs-8200-horizontal-slider-413142/)

U-Factor 0.30–0.32 · 130 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-hs-8200-horizontal-slider-413142/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Custom Window Systems, Inc. SH-8100 Single Hung appear below.

### Where does Custom Window Systems, Inc. SH-8100 Single Hung stand thermally among ENERGY STAR Window lines?

Testing puts Custom Window Systems, Inc. SH-8100 Single Hung at rank #1,344 of 1,352 Window entries with U 0.29 to 0.32 across 157 configurations. Solar heat gain ranges between 0.13 and 0.21 across Southern.

### Is SH-8100 Single Hung approved for Northern Zone heating climates?

No—with 0 Northern packages and a 0.29 thermal floor, Custom Window Systems, Inc. SH-8100 Single Hung targets warmer Southern climates instead of cold Northern installations.

### How does a 3x5 ft SH-8100 Single Hung window perform under a 40 deg F temperature drop?

Using NFRC CWS U-Factor 0.29, a 15 sq ft Single-Hung (VSSH) assembly conducts 174.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+42.0 BTU/hr margin).

### What homeowner profiles are a poor match for Custom Window Systems, Inc. SH-8100 Single Hung?

Skip SH-8100 Single Hung if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on SH-8100 Single Hung options exceeding U 0.22.

### Does SH-8100 Single Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 157 SH-8100 Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.13 rather than higher 0.21 glass.

### What glazing share inside SH-8100 Single Hung qualifies as Most Efficient?

No. Zero of the 157 configurations in Custom Window Systems, Inc. SH-8100 Single Hung hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect SH-8100 Single Hung?

Any SH-8100 Single Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### What permanent glass etch marks verify SH-8100 Single Hung after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.29-0.32, SHGC 0.13-0.21) against permit drawings for line CWS-K-11. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Custom Window Systems, Inc. SH-8100 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)