title: "DRUTEX S.A. IGLO 5 Classic Fixed Window Specs (U 0.15)"
url: https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-fixed-window-413145/
description: "DRUTEX S.A. IGLO 5 Classic Fixed Window (DRU-K-1, Picture Window, Vinyl): U-Factor 0.15-0.32, SHGC 0.04-0.49, 1567 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC DRU · Product Line DRU-K-1 ENERGY STAR Most Efficient Eligible

# DRUTEX S.A. — IGLO 5 Classic Fixed Window · Picture Window

EPA ENERGY STAR Version 7.0 certifies 1,567 variants inside DRUTEX S.A. IGLO 5 Classic Fixed Window, combining Vinyl frame construction with U-Factors spanning 0.15 to 0.32 and SHGC 0.04 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #136 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.04-0.49

- **Certified Options** : 1,567

- **Category Standing** : #136 of 1,352

## How does DRUTEX S.A. IGLO 5 Classic Fixed Window compare thermally against Window peers?

DRUTEX S.A. IGLO 5 Classic Fixed Window achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows DRUTEX S.A. IGLO 5 Classic Fixed Window standing at #136 of 1,352 certified Window product series, tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%. Comparing Vinyl profiles alone (median 0.19) shows -0.04 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 695 configurations meet ENERGY STAR Most Efficient criteria while 927 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.15 U-Factor yields 90.0 BTU/hr transfer (-42.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2023-04-03 licensing and 2023-12-04 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,567 certified glazing combinations for IGLO 5 Classic Fixed Window (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 927 packages (543 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,211 packages (590 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 466 packages (148 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 630 packages (233 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Interstate Building Materials, Inc.** — 442/6802 Awning](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-442-6802-awning-413333/) | Vinyl | 0.15 | 0.15 | 1,544 |
| [**Interstate Building Materials, Inc.** — 442/6802 Casement](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-442-6802-casement-413332/) | Vinyl | 0.15 | 0.15 | 1,680 |
| [**ProVia LLC** — Endure Single Hung](https://ela-ecolandscapingassn.org/windows/models/provia-llc-endure-single-hung-413960/) | Vinyl | 0.15 | 0.12 | 1,743 |
| [**EnergyWall Window** — 7430/3130/8630 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/energywall-window-7430-3130-8630-horizontal-slider-413227/) | Vinyl | 0.15 | 0.14 | 1,348 |
| [**Polaris Windows and Doors** — 7430/3130 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-7430-3130-horizontal-slider-413936/) | Vinyl | 0.15 | 0.14 | 1,348 |

## What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [IGLO Energy Alucover Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-alucover-fixed-window-413166/)

U-Factor 0.14–0.20 · 10 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-alucover-fixed-window-413166/)

Picture WindowMin U 0.15

### [IGLO EDGE Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/)

U-Factor 0.15–0.22 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/)

Picture WindowMin U 0.15

### [IGLO ENERGY Classic Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/)

U-Factor 0.15–0.32 · 3,527 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/)

Sliding Patio DoorMin U 0.15

### [IGLO ENERGY Tilt and Slide Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/)

U-Factor 0.15–0.28 · 2,993 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/)

Picture WindowMin U 0.15

### [MB-79N/MB-86N SI Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/)

U-Factor 0.15–0.32 · 2,540 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/)

Picture WindowMin U 0.16

### [IGLO 5 Fixed Window with GU Threshold](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-fixed-window-with-gu-threshold-413165/)

U-Factor 0.16–0.32 · 774 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-fixed-window-with-gu-threshold-413165/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO 5 Classic Fixed Window appear below.

### How well does IGLO 5 Classic Fixed Window by DRUTEX S.A. insulate relative to Window benchmarks?

Built with Vinyl framing in Fixed Window (FIXD) style, DRUTEX S.A. IGLO 5 Classic Fixed Window offers 1,567 Version 7.0 configurations from U 0.15 up to 0.32, posting -0.05 against the Window median of 0.20 with 695 Most Efficient picks.

### Can homeowners install IGLO 5 Classic Fixed Window in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 927 IGLO 5 Classic Fixed Window packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### What BTU/hr heat transfer results from IGLO 5 Classic Fixed Window's 0.15 minimum U-Factor?

Using NFRC DRU U-Factor 0.15, a 15 sq ft Fixed Window (FIXD) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).

### What are the practical limitations of specifying IGLO 5 Classic Fixed Window?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO 5 Classic Fixed Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### How many IGLO 5 Classic Fixed Window glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 630 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside DRUTEX S.A. IGLO 5 Classic Fixed Window, while total line SHGC reaches 0.49 in colder packages.

### How many DRUTEX S.A. IGLO 5 Classic Fixed Window variants earn ENERGY STAR Most Efficient?

EPA lists 695 Most Efficient options (44.4% share) inside DRUTEX S.A. IGLO 5 Classic Fixed Window, out of 1,567 total Version 7.0 entries.

### What 2026 federal tax credit and Lead RRP rules apply to IGLO 5 Classic Fixed Window?

Any IGLO 5 Classic Fixed Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do you cross-check NFRC DRU and product line DRU-K-1 on delivery?

Match the NFRC thermal sticker for code DRU and line DRU-K-1 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO 5 Classic Fixed Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)