title: "DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door Specs"
url: https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-tilt-and-slide-door-413156/
description: "DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door (DRU-K-12, Sliding Patio Door, Vinyl): U-Factor 0.17-0.28, SHGC 0.14-0.40, 981 options across 4 ENERGY STAR."
---

Door · Vinyl Frame NFRC DRU · Product Line DRU-K-12 ENERGY STAR Most Efficient Eligible

# DRUTEX S.A. — IGLO 5 Classic Tilt and Slide Door · Sliding Patio Door

EPA ENERGY STAR Version 7.0 certifies 981 variants inside DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door, combining Vinyl frame construction with U-Factors spanning 0.17 to 0.28 and SHGC 0.14 to 0.40. Qualifying for Northern, North-Central, South-Central, Southern, this Sliding Patio Door family places #55 of 268 among 268 Door families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.14-0.40

- **Certified Options** : 981

- **Category Standing** : #55 of 268

## How does DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door compare thermally against Door peers?

DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door achieves a 0.17 thermal floor across Door lines, placing #55 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), IGLO 5 Classic Tilt and Slide Door reaches 0.17 on its lowest-conductivity package — #271 of 1,009 in Vinyl, tied with 82 others at 0.17, more insulating than 65.0% of Vinyl lines, top 35.0% (-0.02 vs Vinyl peers). Pairing NFRC ID DRU across multi-pane fills shifts U-Factor from 0.28 down toward 0.17.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 381 configurations meet ENERGY STAR Most Efficient criteria while 686 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors DRU to 2024-04-15 certification (FENSTAR issued 2023-04-03). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 102.0 BTU/hr conductive loss (-22.7% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 981 certified glazing combinations for IGLO 5 Classic Tilt and Slide Door (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 686 packages (229 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 686 packages (284 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 698 packages (149 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 698 packages (246 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Gerkin Windows and Doors** — 6400 Gliding Door](https://ela-ecolandscapingassn.org/windows/models/gerkin-windows-and-doors-6400-gliding-door-413267/) | Vinyl | 0.17 | 0.08 | 600 |
| [**Associated Materials, Inc.** — 11C5/11C6/11C8/11C9/51C9/11i5/11i6/11i8/51i5/51i6/51i8 Patio Door](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-11c5-11c6-11c8-11c9-51c9-11i5-11i6-11i8-51i/) | Vinyl | 0.17 | 0.15 | 1,461 |
| [**Soft-Lite, LLC** — Kingsroyal Patio Door](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-kingsroyal-patio-door-414108/) | Vinyl | 0.17 | 0.12 | 485 |
| [**ProVia LLC** — S-7500 Patio Door](https://ela-ecolandscapingassn.org/windows/models/provia-llc-s-7500-patio-door-413955/) | Vinyl | 0.17 | 0.13 | 164 |
| [**Marvin** — Modern MultiSlide Door](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-multislide-door-413636/) | Fiberglass | 0.17 | 0.11 | 802 |

## What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [IGLO Energy Alucover Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-alucover-fixed-window-413166/)

U-Factor 0.14–0.20 · 10 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-alucover-fixed-window-413166/)

Picture WindowMin U 0.15

### [IGLO 5 Classic Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-fixed-window-413145/)

U-Factor 0.15–0.32 · 1,567 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-fixed-window-413145/)

Picture WindowMin U 0.15

### [IGLO EDGE Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/)

U-Factor 0.15–0.22 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/)

Picture WindowMin U 0.15

### [IGLO ENERGY Classic Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/)

U-Factor 0.15–0.32 · 3,527 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/)

Sliding Patio DoorMin U 0.15

### [IGLO ENERGY Tilt and Slide Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/)

U-Factor 0.15–0.28 · 2,993 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/)

Picture WindowMin U 0.15

### [MB-79N/MB-86N SI Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/)

U-Factor 0.15–0.32 · 2,540 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door appear below.

### How efficient is DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door compared with peer Door models?

Across 981 tested NFRC glazing configurations, DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door with Vinyl framing and Sliding Glass Door (DDSG) style reaches a 0.17 minimum U-Factor and 0.14-0.40 SHGC band. It places #55 among 268 Door series—top 27.6%.

### Which glazing options in DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door meet Northern climate limits?

DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door supplies 686 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.

### How does a 3x5 ft IGLO 5 Classic Tilt and Slide Door window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), IGLO 5 Classic Tilt and Slide Door at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### When should a buyer skip DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO 5 Classic Tilt and Slide Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Is IGLO 5 Classic Tilt and Slide Door suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 698 Southern-approved options within IGLO 5 Classic Tilt and Slide Door spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### What glazing share inside IGLO 5 Classic Tilt and Slide Door qualifies as Most Efficient?

Within IGLO 5 Classic Tilt and Slide Door, 38.8% (381 of 981) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### Can homeowners claim Form 5695 credits on DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 IGLO 5 Classic Tilt and Slide Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### What permanent glass etch marks verify IGLO 5 Classic Tilt and Slide Door after sticker removal?

Verify NFRC ID DRU and series DRU-K-12 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO 5 Classic Tilt and Slide Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)