title: "DRUTEX S.A. IGLO EDGE Casement Specs (U 0.18) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-casement-413178/
description: "DRUTEX S.A. IGLO EDGE Casement (DRU-K-42, Casement Windows, Vinyl): U-Factor 0.18-0.24, SHGC 0.14-0.28, 26 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC DRU · Product Line DRU-K-42 ENERGY STAR Most Efficient Eligible

# DRUTEX S.A. — IGLO EDGE Casement · Casement Windows

Across 40 DRUTEX S.A. certified families, IGLO EDGE Casement supplies 26 Casement Windows configurations starting at 0.18 U-Factor and 0.14 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.24 U-Factor and 0.28 SHGC. Its thermal floor ranks #477 of 1,352 category entries—0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.18

- **SHGC Range** : 0.14-0.28

- **Certified Options** : 26

- **Category Standing** : #477 of 1,352

## How does DRUTEX S.A. IGLO EDGE Casement compare thermally against Window peers?

DRUTEX S.A. IGLO EDGE Casement achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows DRUTEX S.A. IGLO EDGE Casement standing at #477 of 1,352 certified Window product series, tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%. Comparing Vinyl profiles alone (median 0.19) shows -0.01 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 15 configurations meet ENERGY STAR Most Efficient criteria while 9 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2023-04-03 and v7.0 data certification on 2025-07-10. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.18 conducts 108.0 BTU/hr (-24.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 26 certified glazing combinations for IGLO EDGE Casement (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 9 packages (6 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 26 packages (8 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 18 packages (2 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 18 packages (9 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Ideal Window Manufacturing** — 1800 Casement](https://ela-ecolandscapingassn.org/windows/models/ideal-window-manufacturing-1800-casement-413317/) | Vinyl | 0.18 | 0.17 | 26 |
| [**Seven D Windows and Door LLC** — 7700/7800 Double Hung](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-double-hung-414049/) | Vinyl | 0.18 | 0.22 | 34 |
| [**Winchester Industries** — Oxford / Bristol 751/251 Picture Window](https://ela-ecolandscapingassn.org/windows/models/winchester-industries-oxford-bristol-751-251-picture-window-414326/) | Vinyl | 0.18 | 0.15 | 18 |
| [**Ideal Window Manufacturing** — 1800 Awning](https://ela-ecolandscapingassn.org/windows/models/ideal-window-manufacturing-1800-awning-413318/) | Vinyl | 0.18 | 0.11 | 36 |
| [**Vinyl Kraft, Inc.** — Legacy / Heritage / 900 / 9230 PW](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-legacy-heritage-900-9230-pw-414228/) | Vinyl | 0.18 | 0.19 | 36 |

## What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [IGLO Energy Alucover Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-alucover-fixed-window-413166/)

U-Factor 0.14–0.20 · 10 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-alucover-fixed-window-413166/)

Picture WindowMin U 0.15

### [IGLO 5 Classic Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-fixed-window-413145/)

U-Factor 0.15–0.32 · 1,567 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-fixed-window-413145/)

Picture WindowMin U 0.15

### [IGLO EDGE Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/)

U-Factor 0.15–0.22 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/)

Picture WindowMin U 0.15

### [IGLO ENERGY Classic Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/)

U-Factor 0.15–0.32 · 3,527 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/)

Sliding Patio DoorMin U 0.15

### [IGLO ENERGY Tilt and Slide Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/)

U-Factor 0.15–0.28 · 2,993 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/)

Picture WindowMin U 0.15

### [MB-79N/MB-86N SI Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/)

U-Factor 0.15–0.32 · 2,540 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO EDGE Casement appear below.

### What thermal performance numbers separate DRUTEX S.A. IGLO EDGE Casement from peers?

DRUTEX S.A. IGLO EDGE Casement spans 26 certified configurations with U-Factors between 0.18 and 0.24 and SHGC values from 0.14 to 0.28. Ranked #477 of 1,352 Window families, it carries 15 Most Efficient options.

### Can homeowners install IGLO EDGE Casement in cold Northern ENERGY STAR counties?

Yes, 9 packages satisfy Northern ENERGY STAR Version 7.0 rules in IGLO EDGE Casement. Pairing multi-pane insulation down to 0.18 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How does a 3x5 ft IGLO EDGE Casement window perform under a 40 deg F temperature drop?

Using NFRC DRU U-Factor 0.18, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 108.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-24.0 BTU/hr margin).

### What homeowner profiles are a poor match for DRUTEX S.A. IGLO EDGE Casement?

Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO EDGE Casement options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Can you install DRUTEX S.A. IGLO EDGE Casement in Southern or South-Central zones?

Yes. 18 Southern-certified options inside DRUTEX S.A. IGLO EDGE Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.28 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Are all 26 IGLO EDGE Casement configurations ENERGY STAR Most Efficient?

Not every package qualifies: 15 of 26 IGLO EDGE Casement glazing builds earn Most Efficient recognition (57.7%), while other variants sit on the standard Version 7.0 tier.

### What 2026 federal tax credit and Lead RRP rules apply to IGLO EDGE Casement?

Any IGLO EDGE Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do you cross-check NFRC DRU and product line DRU-K-42 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line DRU-K-42 and NFRC ID DRU before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO EDGE Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)