---
title: "DRUTEX S.A. IGLO ENERGY Classic Tilt Turn Specs (U 0.16)"
url: https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-tilt-turn-413150/
description: "DRUTEX S.A. IGLO ENERGY Classic Tilt Turn (DRU-K-6, Dual Action (Tilt Turn), Vinyl): U-Factor 0.16-0.32, SHGC 0.04-0.41, 3652 options across 4 ENERGY STAR."
---

Window · Vinyl Frame NFRC DRU · Product Line DRU-K-6 ENERGY STAR Most Efficient Eligible

# DRUTEX S.A. — IGLO ENERGY Classic Tilt Turn · Dual Action (Tilt Turn)

DRUTEX S.A. engineered the IGLO ENERGY Classic Tilt Turn Dual Action, Tilt Turn line for Northern, North-Central, South-Central, Southern, certifying 3,652 glass-spacer combinations from 0.16 to 0.32 U-Factor and 0.04 to 0.41 SHGC. Relative to other Vinyl models tracked under NFRC DRU, its minimum U-Factor is 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.16

- **SHGC Range** : 0.04-0.41

- **Certified Options** : 3,652

- **Category Standing** : #250 of 1,352

## How does DRUTEX S.A. IGLO ENERGY Classic Tilt Turn compare thermally against Window peers?

DRUTEX S.A. IGLO ENERGY Classic Tilt Turn achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), IGLO ENERGY Classic Tilt Turn is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.16-0.32.

Climate coverage for DRUTEX S.A. IGLO ENERGY Classic Tilt Turn spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 1,980 configurations meet ENERGY STAR Most Efficient criteria while 2,111 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 96.0 BTU/hr (-27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2023-04-03 and cert timestamp 2023-11-15.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,652 certified glazing combinations for IGLO ENERGY Classic Tilt Turn (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 2,111 packages (1,178 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 3,303 packages (1,599 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 1,557 packages (573 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 1,710 packages (954 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Vinylmax LLC** — A4 Single Hung](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-a4-single-hung-414266/) | Vinyl | 0.16 | 0.11 | 3,907 |
| [**MI Windows and Doors, LLC** — 1653 Polyvinyl Chloride (PVC) Double Hung Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1653-polyvinyl-chloride-pvc-double-hung-win/) | Vinyl | 0.16 | 0.06 | 4,599 |
| [**Vinylmax LLC** — A4 Single Slider](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-a4-single-slider-414267/) | Vinyl | 0.16 | 0.11 | 4,620 |
| [**Paradigm Window Solutions** — 8351 Casement](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8351-casement-413973/) | Vinyl | 0.16 | 0.12 | 2,533 |
| [**Seaway Manufacturing Corporation** — Lighthouse/Commander/Epiphany Casement](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-epiphany-casem/) | Vinyl | 0.16 | 0.09 | 2,523 |

## What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [IGLO Energy Alucover Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-alucover-fixed-window-413166/)

U-Factor 0.14–0.20 · 10 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-alucover-fixed-window-413166/)

Picture WindowMin U 0.15

### [IGLO 5 Classic Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-fixed-window-413145/)

U-Factor 0.15–0.32 · 1,567 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-fixed-window-413145/)

Picture WindowMin U 0.15

### [IGLO EDGE Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/)

U-Factor 0.15–0.22 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/)

Picture WindowMin U 0.15

### [IGLO ENERGY Classic Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/)

U-Factor 0.15–0.32 · 3,527 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/)

Sliding Patio DoorMin U 0.15

### [IGLO ENERGY Tilt and Slide Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/)

U-Factor 0.15–0.28 · 2,993 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/)

Picture WindowMin U 0.15

### [MB-79N/MB-86N SI Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/)

U-Factor 0.15–0.32 · 2,540 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO ENERGY Classic Tilt Turn appear below.

### How well does IGLO ENERGY Classic Tilt Turn by DRUTEX S.A. insulate relative to Window benchmarks?

Built with Vinyl framing in Tilt-Turn Dual Action (DATT) style, DRUTEX S.A. IGLO ENERGY Classic Tilt Turn offers 3,652 Version 7.0 configurations from U 0.16 up to 0.32, posting -0.04 against the Window median of 0.20 with 1,980 Most Efficient picks.

### Is IGLO ENERGY Classic Tilt Turn approved for Northern Zone heating climates?

Cold-climate buyers get 2,111 compliant Northern packages inside IGLO ENERGY Classic Tilt Turn, reaching down to U 0.16. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

### What BTU/hr heat transfer results from IGLO ENERGY Classic Tilt Turn's 0.16 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 96.0 BTU/hr on IGLO ENERGY Classic Tilt Turn's lowest-U package (0.16), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### What are the practical limitations of specifying IGLO ENERGY Classic Tilt Turn?

Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO ENERGY Classic Tilt Turn options exceeding U 0.22. Additionally, do not order Tilt-Turn Dual Action (DATT) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### What Southern ENERGY STAR v7.0 options exist in IGLO ENERGY Classic Tilt Turn?

Across Northern, North-Central, South-Central, Southern, 1,710 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside DRUTEX S.A. IGLO ENERGY Classic Tilt Turn, while total line SHGC reaches 0.41 in colder packages.

### What glazing share inside IGLO ENERGY Classic Tilt Turn qualifies as Most Efficient?

EPA lists 1,980 Most Efficient options (54.2% share) inside DRUTEX S.A. IGLO ENERGY Classic Tilt Turn, out of 3,652 total Version 7.0 entries.

### Can homeowners claim Form 5695 credits on DRUTEX S.A. IGLO ENERGY Classic Tilt Turn in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 IGLO ENERGY Classic Tilt Turn installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How do you cross-check NFRC DRU and product line DRU-K-6 on delivery?

Match the NFRC thermal sticker for code DRU and line DRU-K-6 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO ENERGY Classic Tilt Turn come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
