---
title: "DRUTEX S.A. IGLO HS Lift and Slide Door Specs (U 0.17)"
url: https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-hs-lift-and-slide-door-413162/
description: "DRUTEX S.A. IGLO HS Lift and Slide Door (DRU-K-18, Sliding Patio Door, Vinyl): U-Factor 0.17-0.28, SHGC 0.12-0.39, 2324 options across 4 ENERGY STAR zones."
---

Door · Vinyl Frame NFRC DRU · Product Line DRU-K-18 ENERGY STAR Most Efficient Eligible

# DRUTEX S.A. — IGLO HS Lift and Slide Door · Sliding Patio Door

With a minimum U-Factor of 0.17—-0.04 compared against the 0.21 Door median—DRUTEX S.A. IGLO HS Lift and Slide Door spans 2,324 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code DRU, the Vinyl assembly includes 1,223 ENERGY STAR Most Efficient packages (52.6% of line) and offers SHGC packages between 0.12 and 0.39.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.12-0.39

- **Certified Options** : 2,324

- **Category Standing** : #55 of 268

## How does DRUTEX S.A. IGLO HS Lift and Slide Door compare thermally against Door peers?

DRUTEX S.A. IGLO HS Lift and Slide Door achieves a 0.17 thermal floor across Door lines, placing #55 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 40 certified DRUTEX S.A. series, this Sliding Patio Door offers a 0.11 U-Factor adjustment span between 0.28 entry options and 0.17 top-performing glazing. Category standing is #55/268 (tied with 19 others at 0.17, more insulating than 72.4% of Door lines, top 27.6%).

Regional qualification covers Northern, North-Central, South-Central, Southern. 1,223 configurations meet ENERGY STAR Most Efficient criteria while 2,310 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors DRU to 2025-07-10 certification (FENSTAR issued 2023-04-03). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 102.0 BTU/hr conductive loss (-22.7% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,324 certified glazing combinations for IGLO HS Lift and Slide Door (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 2,310 packages (849 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 2,310 packages (1,145 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 553 packages (383 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 553 packages (461 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Associated Materials, Inc.** — 11C5/11C6/11C8/11C9/51C9/11i5/11i6/11i8/51i5/51i6/51i8 Patio Door](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-11c5-11c6-11c8-11c9-51c9-11i5-11i6-11i8-51i/) | Vinyl | 0.17 | 0.15 | 1,461 |
| [**Gerkin Windows and Doors** — 6400 Gliding Door](https://ela-ecolandscapingassn.org/windows/models/gerkin-windows-and-doors-6400-gliding-door-413267/) | Vinyl | 0.17 | 0.08 | 600 |
| [**Soft-Lite, LLC** — Kingsroyal Patio Door](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-kingsroyal-patio-door-414108/) | Vinyl | 0.17 | 0.12 | 485 |
| [**ProVia LLC** — S-7500 Patio Door](https://ela-ecolandscapingassn.org/windows/models/provia-llc-s-7500-patio-door-413955/) | Vinyl | 0.17 | 0.13 | 164 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra/VistaLuxe Inswing Entrance Door](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-vistaluxe-inswing-entrance-doo/) | Wood | 0.17 | 0.04 | 3,719 |

## What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [IGLO Energy Alucover Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-alucover-fixed-window-413166/)

U-Factor 0.14–0.20 · 10 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-alucover-fixed-window-413166/)

Picture WindowMin U 0.15

### [IGLO 5 Classic Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-fixed-window-413145/)

U-Factor 0.15–0.32 · 1,567 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-fixed-window-413145/)

Picture WindowMin U 0.15

### [IGLO EDGE Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/)

U-Factor 0.15–0.22 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/)

Picture WindowMin U 0.15

### [IGLO ENERGY Classic Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/)

U-Factor 0.15–0.32 · 3,527 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/)

Sliding Patio DoorMin U 0.15

### [IGLO ENERGY Tilt and Slide Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/)

U-Factor 0.15–0.28 · 2,993 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/)

Picture WindowMin U 0.15

### [MB-79N/MB-86N SI Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/)

U-Factor 0.15–0.32 · 2,540 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO HS Lift and Slide Door appear below.

### What U-Factor and SHGC range does DRUTEX S.A. IGLO HS Lift and Slide Door achieve?

Testing puts DRUTEX S.A. IGLO HS Lift and Slide Door at rank #55 of 268 Door entries with U 0.17 to 0.28 across 2,324 configurations. Solar heat gain ranges between 0.12 and 0.39 across Northern, North-Central, South-Central, Southern.

### Can homeowners install IGLO HS Lift and Slide Door in cold Northern ENERGY STAR counties?

Yes, 2,310 packages satisfy Northern ENERGY STAR Version 7.0 rules in IGLO HS Lift and Slide Door. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### What conductive BTU/hr difference separates IGLO HS Lift and Slide Door from the 0.22 Northern rule?

Using NFRC DRU U-Factor 0.17, a 15 sq ft Sliding Glass Door (DDSG) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).

### Which situations make IGLO HS Lift and Slide Door the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO HS Lift and Slide Door options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### How many IGLO HS Lift and Slide Door glazing packages pass Southern solar-heat rules?

Exactly 553 IGLO HS Lift and Slide Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.12 rather than higher 0.39 glass.

### Are all 2,324 IGLO HS Lift and Slide Door configurations ENERGY STAR Most Efficient?

EPA lists 1,223 Most Efficient options (52.6% share) inside DRUTEX S.A. IGLO HS Lift and Slide Door, out of 2,324 total Version 7.0 entries.

### Can homeowners claim Form 5695 credits on DRUTEX S.A. IGLO HS Lift and Slide Door in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 IGLO HS Lift and Slide Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### What permanent glass etch marks verify IGLO HS Lift and Slide Door after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.17-0.28, SHGC 0.12-0.39) against permit drawings for line DRU-K-18. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO HS Lift and Slide Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
