title: "DRUTEX S.A. IGLO LIGHT Casement Specs (U 0.21)"
url: https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-light-casement-413182/
description: "DRUTEX S.A. IGLO LIGHT Casement (DRU-K-46, Casement Windows, Vinyl): U-Factor 0.21-0.28, SHGC 0.17-0.29, 5 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC DRU · Product Line DRU-K-46

# DRUTEX S.A. — IGLO LIGHT Casement · Casement Windows

With a minimum U-Factor of 0.21—+0.01 compared against the 0.20 Window median—DRUTEX S.A. IGLO LIGHT Casement spans 5 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code DRU, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.17 and 0.29.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.17-0.29

- **Certified Options** : 5

- **Category Standing** : #742 of 1,352

## How does DRUTEX S.A. IGLO LIGHT Casement compare thermally against Window peers?

DRUTEX S.A. IGLO LIGHT Casement achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 40 certified DRUTEX S.A. series, this Casement Windows offers a 0.07 U-Factor adjustment span between 0.28 entry options and 0.21 top-performing glazing. Category standing is #742/1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines).

Regional qualification covers Northern, North-Central, South-Central, Southern. 2 combinations qualify in the Northern Zone alongside 2 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.21 U-Factor yields 126.0 BTU/hr transfer (-6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2023-04-03 licensing and 2025-07-10 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 5 certified glazing combinations for IGLO LIGHT Casement (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 2 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 3 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 2 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 2 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Thermal-Gard Building Products, Inc.** — 501/551/601/651 Single Hung Picture Window](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-501-551-601-651-single-hung-pictu/) | Vinyl | 0.21 | 0.24 | 4 |
| [**Thermal-Gard Building Products, Inc.** — 851/951 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-851-951-casement-picture-window-4/) | Vinyl | 0.21 | 0.23 | 8 |
| [**Kohltech International, Ltd.** — Supreme Single Glider](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-supreme-single-glider-413493/) | Vinyl | 0.21 | 0.21 | 11 |
| [**Energy King Windows & Doors Inc.** — Pro Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/energy-king-windows-doors-inc-pro-series-horizontal-slider-414084/) | Vinyl | 0.21 | 0.22 | 12 |
| [**Kohltech International, Ltd.** — Supreme Single Hung](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-supreme-single-hung-413494/) | Vinyl | 0.21 | 0.21 | 15 |

## What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [IGLO Energy Alucover Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-alucover-fixed-window-413166/)

U-Factor 0.14–0.20 · 10 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-alucover-fixed-window-413166/)

Picture WindowMin U 0.15

### [IGLO 5 Classic Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-fixed-window-413145/)

U-Factor 0.15–0.32 · 1,567 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-fixed-window-413145/)

Picture WindowMin U 0.15

### [IGLO EDGE Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/)

U-Factor 0.15–0.22 · 26 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/)

Picture WindowMin U 0.15

### [IGLO ENERGY Classic Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/)

U-Factor 0.15–0.32 · 3,527 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/)

Sliding Patio DoorMin U 0.15

### [IGLO ENERGY Tilt and Slide Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/)

U-Factor 0.15–0.28 · 2,993 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/)

Picture WindowMin U 0.15

### [MB-79N/MB-86N SI Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/)

U-Factor 0.15–0.32 · 2,540 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO LIGHT Casement appear below.

### What thermal performance numbers separate DRUTEX S.A. IGLO LIGHT Casement from peers?

Across 5 tested NFRC glazing configurations, DRUTEX S.A. IGLO LIGHT Casement with Vinyl framing and Casement Single-Vent (CSSV) style reaches a 0.21 minimum U-Factor and 0.17-0.29 SHGC band. It places #742 among 1,352 Window series—more insulating than 38.6%.

### Is IGLO LIGHT Casement approved for Northern Zone heating climates?

Yes, 2 packages satisfy Northern ENERGY STAR Version 7.0 rules in IGLO LIGHT Casement. Pairing multi-pane insulation down to 0.21 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How does a 3x5 ft IGLO LIGHT Casement window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 126.0 BTU/hr on IGLO LIGHT Casement's lowest-U package (0.21), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

### Which situations make IGLO LIGHT Casement the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO LIGHT Casement options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### What Southern ENERGY STAR v7.0 options exist in IGLO LIGHT Casement?

Exactly 2 IGLO LIGHT Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.17 rather than higher 0.29 glass.

### Does IGLO LIGHT Casement carry EPA Most Efficient certification across its lineup?

IGLO LIGHT Casement holds zero Most Efficient entries across its 5 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

### What federal compliance checks govern 2026 IGLO LIGHT Casement window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current IGLO LIGHT Casement retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do you cross-check NFRC DRU and product line DRU-K-46 on delivery?

Inspectors match the temporary NFRC sticker (U 0.21-0.28, SHGC 0.17-0.29) against permit drawings for line DRU-K-46. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO LIGHT Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)