title: "Earthwise Group 143.000/145.000/343.000/443.000/643.000"
url: https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-143-000-145-000-343-000-443-000-643-000-picture/
description: "Earthwise Group 143.000/145.000/343.000/443.000/643.000 Picture Window (EWG-K-5, Picture Window, Vinyl): U-Factor 0.21-0.31, SHGC 0.14-0.52, 299 options."
---

Window · Vinyl Frame NFRC EWG · Product Line EWG-K-5 ENERGY STAR Most Efficient Eligible

# Earthwise Group, LLC — 143.000/145.000/343.000/443.000/643.000 Picture Window · Picture Window

Positioning #742/1,352 in certified Window, Earthwise Group, LLC 143.000/145.000/343.000/443.000/643.000 Picture Window pairs Vinyl frame construction with 299 glazing options rated between 0.14 and 0.52 SHGC across Northern, North-Central, South-Central, Southern. Across 7 certified Earthwise Group, LLC product families, its thermal resistance spans 0.21 to 0.31 U-Factor and the line includes 21 ENERGY STAR Most Efficient packages (7.0% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.14-0.52

- **Certified Options** : 299

- **Category Standing** : #742 of 1,352

## How does Earthwise Group, LLC 143.000/145.000/343.000/443.000/643.000 Picture Window compare thermally against Window peers?

Earthwise Group, LLC 143.000/145.000/343.000/443.000/643.000 Picture Window achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Earthwise Group, LLC 143.000/145.000/343.000/443.000/643.000 Picture Window standing at #742 of 1,352 certified Window product series, tied with 88 others at 0.21, more insulating than 38.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.02 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. 21 configurations meet ENERGY STAR Most Efficient criteria while 104 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors EWG to 2024-11-05 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 126.0 BTU/hr conductive loss (-4.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 299 certified glazing combinations for 143.000/145.000/343.000/443.000/643.000 Picture Window (NFRC EWG) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 104 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 154 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 150 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 160 packages (21 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Windsor Windows and Doors** — Next Dimension Pro Brickmould Direct Set](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-pro-brickmould-direct-set-4/) | Vinyl | 0.21 | 0.18 | 298 |
| [**Anlin Industries** — Monte Verde Fixed](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-monte-verde-fixed-413035/) | Vinyl | 0.21 | 0.14 | 296 |
| [**Windsor Windows and Doors** — Next Dimension Pro Direct Set / Radius](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-pro-direct-set-radius-41442/) | Vinyl | 0.21 | 0.18 | 303 |
| [**Gerkin Windows and Doors** — 6500 Fixed Window](https://ela-ecolandscapingassn.org/windows/models/gerkin-windows-and-doors-6500-fixed-window-413266/) | Vinyl | 0.21 | 0.10 | 266 |
| [**Northeast Windows USA, Inc.** — CW300 Casement](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-cw300-casement-413811/) | Vinyl | 0.21 | 0.08 | 266 |

## What other certified series does Earthwise Group, LLC produce?

Compare other active Earthwise Group, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Awning (Projected)Min U 0.21

### [140.148 / 143.191 / 143.148 Awning](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-140-148-143-191-143-148-awning-413205/)

U-Factor 0.21–0.32 · 289 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-140-148-143-191-143-148-awning-413205/)

Casement WindowsMin U 0.21

### [140.148 / 143.191 / 143.148 Casement](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-140-148-143-191-143-148-casement-413204/)

U-Factor 0.21–0.32 · 280 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-140-148-143-191-143-148-casement-413204/)

Single HungMin U 0.22

### [143.093,.095/343.293,.295/443.095,.293,.295/642.295/643.295/743.095,.295 SH](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-143-093-095-343-293-295-443-095-293-295-642-295/)

U-Factor 0.22–0.32 · 842 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-143-093-095-343-293-295-443-095-293-295-642-295/)

Single SliderMin U 0.22

### [143.093/143.095/343.095/343.293/343.295/443.095/443.293/443.295/642.295/643.295 Single Slider](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-143-093-143-095-343-095-343-293-343-295-443-095/)

U-Factor 0.22–0.32 · 834 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-143-093-143-095-343-095-343-293-343-295-443-095/)

Picture WindowMin U 0.22

### [177.000 Picture Window](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-177-000-picture-window-413207/)

U-Factor 0.22–0.28 · 6 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-177-000-picture-window-413207/)

Double HungMin U 0.23

### [143.095,.195/145.095,.195/144.195/343.095/443.095,.295/643.095,.195/642.295/743.095,.295 DH](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-143-095-195-145-095-195-144-195-343-095-443-095/)

U-Factor 0.23–0.32 · 562 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-143-095-195-145-095-195-144-195-343-095-443-095/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Earthwise Group, LLC 143.000/145.000/343.000/443.000/643.000 Picture Window appear below.

### How well does 143.000/145.000/343.000/443.000/643.000 Picture Window by Earthwise Group, LLC insulate relative to Window benchmarks?

Testing puts Earthwise Group, LLC 143.000/145.000/343.000/443.000/643.000 Picture Window at rank #742 of 1,352 Window entries with U 0.21 to 0.31 across 299 configurations. Solar heat gain ranges between 0.14 and 0.52 across Northern, North-Central, South-Central, Southern.

### Which glazing options in Earthwise Group, LLC 143.000/145.000/343.000/443.000/643.000 Picture Window meet Northern climate limits?

Yes. 104 packages in Earthwise Group, LLC 143.000/145.000/343.000/443.000/643.000 Picture Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.31.

### How do you calculate winter heat conduction for Earthwise Group, LLC 143.000/145.000/343.000/443.000/643.000 Picture Window?

At U 0.21, a standard 3x5 ft (15 sq ft) 143.000/145.000/343.000/443.000/643.000 Picture Window opening transfers 126.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -6.0 BTU/hr difference.

### Which situations make 143.000/145.000/343.000/443.000/643.000 Picture Window the wrong window or door choice?

Skip 143.000/145.000/343.000/443.000/643.000 Picture Window if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 143.000/145.000/343.000/443.000/643.000 Picture Window options exceeding U 0.22.

### How many 143.000/145.000/343.000/443.000/643.000 Picture Window glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 160 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Earthwise Group, LLC 143.000/145.000/343.000/443.000/643.000 Picture Window, while total line SHGC reaches 0.52 in colder packages.

### What glazing share inside 143.000/145.000/343.000/443.000/643.000 Picture Window qualifies as Most Efficient?

EPA lists 21 Most Efficient options (7.0% share) inside Earthwise Group, LLC 143.000/145.000/343.000/443.000/643.000 Picture Window, out of 299 total Version 7.0 entries.

### What federal compliance checks govern 2026 143.000/145.000/343.000/443.000/643.000 Picture Window window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 143.000/145.000/343.000/443.000/643.000 Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### Where are NFRC and IGCC identification marks located on 143.000/145.000/343.000/443.000/643.000 Picture Window?

Inspectors match the temporary NFRC sticker (U 0.21-0.31, SHGC 0.14-0.52) against permit drawings for line EWG-K-5. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Earthwise Group, LLC 143.000/145.000/343.000/443.000/643.000 Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)