title: "EnergyWall Window 8480/7480/3080 Patio Door Specs (U 0.16)"
url: https://ela-ecolandscapingassn.org/windows/models/energywall-window-8480-7480-3080-patio-door-413224/
description: "EnergyWall Window 8480/7480/3080 Patio Door (EWW-M-12, Sliding Patio Door, Vinyl): U-Factor 0.16-0.28, SHGC 0.15-0.37, 3179 options across 4 ENERGY STAR."
---

Door · Vinyl Frame NFRC EWW · Product Line EWW-M-12 ENERGY STAR Most Efficient Eligible

# EnergyWall Window — 8480/7480/3080 Patio Door · Sliding Patio Door

EPA ENERGY STAR Version 7.0 certifies 3,179 variants inside EnergyWall Window 8480/7480/3080 Patio Door, combining Vinyl frame construction with U-Factors spanning 0.16 to 0.28 and SHGC 0.15 to 0.37. Qualifying for Northern, North-Central, South-Central, Southern, this Sliding Patio Door family places #29 of 268 among 268 Door families and posts 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.16

- **SHGC Range** : 0.15-0.37

- **Certified Options** : 3,179

- **Category Standing** : #29 of 268

## How does EnergyWall Window 8480/7480/3080 Patio Door compare thermally against Door peers?

EnergyWall Window 8480/7480/3080 Patio Door achieves a 0.16 thermal floor across Door lines, placing #29 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), 8480/7480/3080 Patio Door is 0.05 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.16-0.28.

Regional qualification covers Northern, North-Central, South-Central, Southern. 961 configurations meet ENERGY STAR Most Efficient criteria while 2,496 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 96.0 BTU/hr (-27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2026-02-26.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,179 certified glazing combinations for 8480/7480/3080 Patio Door (NFRC EWW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 2,496 packages (408 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 2,496 packages (702 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 2,494 packages (625 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,494 packages (884 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Polaris Windows and Doors** — 8480/7480/3080 Patio Door](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-8480-7480-3080-patio-door-413933/) | Vinyl | 0.16 | 0.15 | 3,179 |
| [**DRUTEX S.A.** — IGLO Energy Outswing Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-outswing-door-413160/) | Vinyl | 0.16 | 0.01 | 3,085 |
| [**DRUTEX S.A.** — IGLO Energy Inswing Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-inswing-door-413159/) | Vinyl | 0.16 | 0.01 | 2,626 |
| [**Innotech Windows & Doors Inc.** — Defender 76 TS Tilt and Glide Door](https://ela-ecolandscapingassn.org/windows/models/innotech-windows-doors-inc-defender-76-ts-tilt-and-glide-door-413334/) | Vinyl | 0.16 | 0.11 | 2,186 |
| [**Euroline Windows Inc.** — Energeto Neo-76 Inswing/Outswing Door](https://ela-ecolandscapingassn.org/windows/models/euroline-windows-inc-energeto-neo-76-inswing-outswing-door-413025/) | Vinyl | 0.16 | 0.11 | 1,761 |

## What other certified series does EnergyWall Window produce?

Compare other active EnergyWall Window certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [8605/3205 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/energywall-window-8605-3205-casement-picture-window-413230/)

U-Factor 0.13–0.29 · 3,472 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/energywall-window-8605-3205-casement-picture-window-413230/)

Picture WindowMin U 0.14

### [7400/3100 Picture Window](https://ela-ecolandscapingassn.org/windows/models/energywall-window-7400-3100-picture-window-413225/)

U-Factor 0.14–0.29 · 3,407 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/energywall-window-7400-3100-picture-window-413225/)

Double HungMin U 0.15

### [7420/3120/8620 Double Hung](https://ela-ecolandscapingassn.org/windows/models/energywall-window-7420-3120-8620-double-hung-413226/)

U-Factor 0.15–0.32 · 1,340 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/energywall-window-7420-3120-8620-double-hung-413226/)

Double SliderMin U 0.15

### [7430/3130/8630 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/energywall-window-7430-3130-8630-horizontal-slider-413227/)

U-Factor 0.15–0.32 · 1,348 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/energywall-window-7430-3130-8630-horizontal-slider-413227/)

Casement WindowsMin U 0.15

### [8650/3151 Casement](https://ela-ecolandscapingassn.org/windows/models/energywall-window-8650-3151-casement-413228/)

U-Factor 0.15–0.27 · 2,568 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/energywall-window-8650-3151-casement-413228/)

Awning (Projected)Min U 0.15

### [8660 Awning](https://ela-ecolandscapingassn.org/windows/models/energywall-window-8660-awning-413229/)

U-Factor 0.15–0.27 · 2,542 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/energywall-window-8660-awning-413229/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to EnergyWall Window 8480/7480/3080 Patio Door appear below.

### What U-Factor and SHGC range does EnergyWall Window 8480/7480/3080 Patio Door achieve?

EPA ENERGY STAR v7.0 records 3,179 configurations for EnergyWall Window 8480/7480/3080 Patio Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.16 versus a 0.21 Door median. Only 961 options earn Most Efficient status.

### Can homeowners install 8480/7480/3080 Patio Door in cold Northern ENERGY STAR counties?

Cold-climate buyers get 2,496 compliant Northern packages inside 8480/7480/3080 Patio Door, reaching down to U 0.16. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

### What BTU/hr heat transfer results from 8480/7480/3080 Patio Door's 0.16 minimum U-Factor?

Using NFRC EWW U-Factor 0.16, a 15 sq ft Sliding Glass Door (DDSG) assembly conducts 96.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-36.0 BTU/hr margin).

### What are the practical limitations of specifying 8480/7480/3080 Patio Door?

Do not specify 8480/7480/3080 Patio Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 8480/7480/3080 Patio Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### How many 8480/7480/3080 Patio Door glazing packages pass Southern solar-heat rules?

Yes, 8480/7480/3080 Patio Door holds 2,494 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.

### What glazing share inside 8480/7480/3080 Patio Door qualifies as Most Efficient?

No. Exactly 961 of 3,179 configurations (30.2%) earn ENERGY STAR Most Efficient status in 8480/7480/3080 Patio Door; the remaining standard v7.0 options pass base zone limits only.

### What federal compliance checks govern 2026 8480/7480/3080 Patio Door window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do building inspectors verify 8480/7480/3080 Patio Door glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.16-0.28, SHGC 0.15-0.37) against permit drawings for line EWW-M-12. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for EnergyWall Window 8480/7480/3080 Patio Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)