---
title: "Glass Rite EnergyQuest Horizontal Slider Specs (U 0.15)"
url: https://ela-ecolandscapingassn.org/windows/models/glass-rite-energyquest-horizontal-slider-413268/
description: "Glass Rite EnergyQuest Horizontal Slider (GLR-K-13, Single Slider, Vinyl): U-Factor 0.15-0.32, SHGC 0.16-0.31, 1033 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC GLR · Product Line GLR-K-13 ENERGY STAR Most Efficient Eligible

# Glass Rite — EnergyQuest Horizontal Slider · Single Slider

Glass Rite engineered the EnergyQuest Horizontal Slider Single Slider line for Northern, North-Central, South-Central, Southern, certifying 1,033 glass-spacer combinations from 0.15 to 0.32 U-Factor and 0.16 to 0.31 SHGC. Relative to other Vinyl models tracked under NFRC GLR, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.16-0.31

- **Certified Options** : 1,033

- **Category Standing** : #136 of 1,352

## How does Glass Rite EnergyQuest Horizontal Slider compare thermally against Window peers?

Glass Rite EnergyQuest Horizontal Slider achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across EnergyQuest Horizontal Slider spans 1,033 NFRC test records (GLR), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.04 against the Vinyl median (0.19).

Regional qualification covers Northern, North-Central, South-Central, Southern. 287 configurations meet ENERGY STAR Most Efficient criteria while 296 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-10-24 and FENSTAR license 2018-08-23 inside EPA Version 7.0 tables. Heat transfer computes to 90.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,033 certified glazing combinations for EnergyQuest Horizontal Slider (NFRC GLR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 296 packages (55 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 687 packages (171 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 708 packages (120 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 808 packages (236 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Soft-Lite, LLC** — Awning](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-awning-414110/) | Vinyl | 0.15 | 0.11 | 1,020 |
| [**Soft-Lite, LLC** — Casement](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-casement-414109/) | Vinyl | 0.15 | 0.11 | 1,066 |
| [**ProVia LLC** — Endure Single Slide](https://ela-ecolandscapingassn.org/windows/models/provia-llc-endure-single-slide-413958/) | Vinyl | 0.15 | 0.12 | 1,117 |
| [**Euroline Windows Inc.** — Energeto Neo-76 Tilt and Turn Window](https://ela-ecolandscapingassn.org/windows/models/euroline-windows-inc-energeto-neo-76-tilt-and-turn-window-413024/) | Vinyl | 0.15 | 0.13 | 1,299 |
| [**EnergyWall Window** — 7420/3120/8620 Double Hung](https://ela-ecolandscapingassn.org/windows/models/energywall-window-7420-3120-8620-double-hung-413226/) | Vinyl | 0.15 | 0.15 | 1,340 |

## What other certified series does Glass Rite produce?

Compare other active Glass Rite certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single HungMin U 0.15

### [EnergyQuest Tilt Single Hung](https://ela-ecolandscapingassn.org/windows/models/glass-rite-energyquest-tilt-single-hung-413269/)

U-Factor 0.15–0.32 · 1,057 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/glass-rite-energyquest-tilt-single-hung-413269/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Glass Rite EnergyQuest Horizontal Slider appear below.

### Where does Glass Rite EnergyQuest Horizontal Slider stand thermally among ENERGY STAR Window lines?

Glass Rite EnergyQuest Horizontal Slider spans 1,033 certified configurations with U-Factors between 0.15 and 0.32 and SHGC values from 0.16 to 0.31. Ranked #136 of 1,352 Window families, it carries 287 Most Efficient options.

### Does Glass Rite EnergyQuest Horizontal Slider qualify for the ENERGY STAR Northern Zone?

Glass Rite EnergyQuest Horizontal Slider supplies 296 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

### How much winter heat loss does EnergyQuest Horizontal Slider conduct across a 15 sq ft opening?

Using NFRC GLR U-Factor 0.15, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).

### Who should NOT choose Glass Rite EnergyQuest Horizontal Slider for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on EnergyQuest Horizontal Slider options exceeding U 0.22. Additionally, do not order Horizontal Slider (HSOX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Does EnergyQuest Horizontal Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 808 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Glass Rite EnergyQuest Horizontal Slider, while total line SHGC reaches 0.31 in colder packages.

### How many Glass Rite EnergyQuest Horizontal Slider variants earn ENERGY STAR Most Efficient?

Not every package qualifies: 287 of 1,033 EnergyQuest Horizontal Slider glazing builds earn Most Efficient recognition (27.8%), while other variants sit on the standard Version 7.0 tier.

### What 2026 federal tax credit and Lead RRP rules apply to EnergyQuest Horizontal Slider?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current EnergyQuest Horizontal Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How can homeowners confirm delivered Glass Rite EnergyQuest Horizontal Slider units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line GLR-K-13 and NFRC ID GLR before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Glass Rite EnergyQuest Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
