---
title: "Harvey Industries Vinyl Hopper Specs (U 0.23) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-vinyl-hopper-413293/
description: "Harvey Industries Vinyl Hopper (HII-M-8, Awning (Projected), Vinyl): U-Factor 0.23-0.32, SHGC 0.16-0.40, 181 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC HII · Product Line HII-M-8

# Harvey Industries, Inc. — Vinyl Hopper · Awning (Projected)

Harvey Industries, Inc. engineered the Vinyl Hopper Awning, Projected line for Northern, North-Central, South-Central, Southern, certifying 181 glass-spacer combinations from 0.23 to 0.32 U-Factor and 0.16 to 0.40 SHGC. Relative to other Vinyl models tracked under NFRC HII, its minimum U-Factor is 0.04 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.16-0.40

- **Certified Options** : 181

- **Category Standing** : #936 of 1,352

## How does Harvey Industries, Inc. Vinyl Hopper compare thermally against Window peers?

Harvey Industries, Inc. Vinyl Hopper achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Harvey Industries, Inc. Vinyl Hopper standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 6 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors HII to 2025-01-31 certification (FENSTAR issued 2018-10-03). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 181 certified glazing combinations for Vinyl Hopper (NFRC HII) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 6 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 35 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 90 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 170 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**United Window & Door Mfg., Inc.** — 3800 - 3900 Single Hung Vinyl Window](https://ela-ecolandscapingassn.org/windows/models/united-window-door-mfg-inc-3800-3900-single-hung-vinyl-window-414210/) | Vinyl | 0.23 | 0.18 | 156 |
| [**Interstate Building Materials, Inc.** — 145/5000/5100/5200 Double Hung](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-145-5000-5100-5200-double-hung-413/) | Vinyl | 0.23 | 0.18 | 136 |
| [**Anlin Industries** — Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-e-del-mar-e-bayview-panoramic-extreme-e-ho/) | Vinyl | 0.23 | 0.13 | 230 |
| [**Anlin Industries** — Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-e-del-mar-e-bayview-panoramic-extreme-e-si/) | Vinyl | 0.23 | 0.13 | 230 |
| [**Silver Line Building Products** — 2050/2130/2250/2350 Picture Window](https://ela-ecolandscapingassn.org/windows/models/silver-line-building-products-2050-2130-2250-2350-picture-window-414/) | Vinyl | 0.23 | 0.20 | 242 |

## What other certified series does Harvey Industries, Inc. produce?

Compare other active Harvey Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Axio Direct Set Fixed Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-axio-direct-set-fixed-window-413307/)

U-Factor 0.13–0.30 · 725 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-axio-direct-set-fixed-window-413307/)

Dual Action (Tilt Turn)Min U 0.14

### [Axio Tilt Turn Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-axio-tilt-turn-window-413308/)

U-Factor 0.14–0.30 · 3,474 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-axio-tilt-turn-window-413308/)

Picture WindowMin U 0.14

### [Vinyl Fixed Casement Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-vinyl-fixed-casement-window-413303/)

U-Factor 0.14–0.32 · 14,146 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-vinyl-fixed-casement-window-413303/)

Awning (Projected)Min U 0.16

### [Vinyl Awning Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-vinyl-awning-window-413302/)

U-Factor 0.16–0.32 · 12,087 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-vinyl-awning-window-413302/)

Casement WindowsMin U 0.16

### [Vinyl Casement Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-vinyl-casement-window-413301/)

U-Factor 0.16–0.32 · 12,695 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-vinyl-casement-window-413301/)

Picture WindowMin U 0.17

### [Vinyl Picture Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-vinyl-picture-window-413294/)

U-Factor 0.17–0.32 · 534 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-vinyl-picture-window-413294/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Harvey Industries, Inc. Vinyl Hopper appear below.

### How efficient is Harvey Industries, Inc. Vinyl Hopper compared with peer Window models?

Built with Vinyl framing in Projected Awning (PRAW) style, Harvey Industries, Inc. Vinyl Hopper offers 181 Version 7.0 configurations from U 0.23 up to 0.32, posting +0.03 against the Window median of 0.20 with 0 Most Efficient picks.

### Does Harvey Industries, Inc. Vinyl Hopper qualify for the ENERGY STAR Northern Zone?

Because Vinyl Hopper starts at 0.23 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 6 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

### How does a 3x5 ft Vinyl Hopper window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What homeowner profiles are a poor match for Harvey Industries, Inc. Vinyl Hopper?

Do not specify Vinyl Hopper without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Vinyl Hopper options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in Vinyl Hopper?

Across Northern, North-Central, South-Central, Southern, 170 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Harvey Industries, Inc. Vinyl Hopper, while total line SHGC reaches 0.40 in colder packages.

### Are all 181 Vinyl Hopper configurations ENERGY STAR Most Efficient?

All 181 Vinyl Hopper listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### Can homeowners claim Form 5695 credits on Harvey Industries, Inc. Vinyl Hopper in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Harvey Industries, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do you cross-check NFRC HII and product line HII-M-8 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line HII-M-8 and NFRC ID HII before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Harvey Industries, Inc. Vinyl Hopper come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
