title: "JELD-WEN 7500 Single Hung Specs (U 0.14) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/
description: "JELD-WEN 7500 Single Hung (JEL-A-1009, Single Hung, Vinyl): U-Factor 0.14-0.32, SHGC 0.15-0.56, 42169 options across 4 ENERGY STAR zones. Verified against."
---

Window · Vinyl Frame NFRC JEL · Product Line JEL-A-1009 ENERGY STAR Most Efficient Eligible

# JELD-WEN, inc. — 7500 Single Hung · Single Hung

JELD-WEN, inc. engineered the 7500 Single Hung Single Hung line for Northern, North-Central, South-Central, Southern, certifying 42,169 glass-spacer combinations from 0.14 to 0.32 U-Factor and 0.15 to 0.56 SHGC. Relative to other Vinyl models tracked under NFRC JEL, its minimum U-Factor is 0.05 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.14

- **SHGC Range** : 0.15-0.56

- **Certified Options** : 42,169

- **Category Standing** : #72 of 1,352

## How does JELD-WEN, inc. 7500 Single Hung compare thermally against Window peers?

JELD-WEN, inc. 7500 Single Hung achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 61 certified JELD-WEN, inc. series, this Single Hung offers a 0.18 U-Factor adjustment span between 0.32 entry options and 0.14 top-performing glazing. Category standing is #72/1,352 (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%).

Climate coverage for JELD-WEN, inc. 7500 Single Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 8,400 configurations meet ENERGY STAR Most Efficient criteria while 17,567 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 84.0 BTU/hr (-36.4% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2026-08-06.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 42,169 certified glazing combinations for 7500 Single Hung (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 17,567 packages (4,307 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 23,406 packages (5,581 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 17,148 packages (3,223 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 23,890 packages (5,679 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**MI Windows and Doors, LLC** — 3075/3065 Direct Set Picture Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-3075-3065-direct-set-picture-window-413710/) | Vinyl | 0.14 | 0.09 | 35,308 |
| [**Milgard Manufacturing, Inc.** — 8340T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/) | Vinyl | 0.14 | 0.09 | 35,182 |
| [**Simonton Building Products, Inc. - Simonton Windows** — 07-09 / 07-10 / 07-20 / 07-75 PW](https://ela-ecolandscapingassn.org/windows/models/simonton-building-products-inc-simonton-windows-07-09-07-10-07-20-07/) | Vinyl | 0.14 | 0.08 | 52,166 |
| [**Wincore Window Company, LLC** — 7700, 8400, 8800 Picture Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-7700-8400-8800-picture-window-414346/) | Vinyl | 0.14 | 0.08 | 28,216 |
| [**Associated Materials, Inc.** — A681/691 Awning](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a681-691-awning-413063/) | Vinyl | 0.14 | 0.05 | 60,157 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

Picture WindowMin U 0.14

### [Siteline Clad Wood (W-5500) Fixed Direct Set Geo](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-clad-wood-w-5500-fixed-direct-set-geo-413384/)

U-Factor 0.14–0.32 · 4,582 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-clad-wood-w-5500-fixed-direct-set-geo-413384/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. 7500 Single Hung appear below.

### What thermal performance numbers separate JELD-WEN, inc. 7500 Single Hung from peers?

Testing puts JELD-WEN, inc. 7500 Single Hung at rank #72 of 1,352 Window entries with U 0.14 to 0.32 across 42,169 configurations. Solar heat gain ranges between 0.15 and 0.56 across Northern, North-Central, South-Central, Southern.

### Does JELD-WEN, inc. 7500 Single Hung qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 17,567 7500 Single Hung packages (U floor 0.14, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### What BTU/hr heat transfer results from 7500 Single Hung's 0.14 minimum U-Factor?

Using NFRC JEL U-Factor 0.14, a 15 sq ft Single-Hung (VSSH) assembly conducts 84.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-48.0 BTU/hr margin).

### Who should NOT choose JELD-WEN, inc. 7500 Single Hung for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 7500 Single Hung options exceeding U 0.22. Additionally, do not order Single-Hung (VSSH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### How many 7500 Single Hung glazing packages pass Southern solar-heat rules?

Yes, 7500 Single Hung holds 23,890 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.

### What glazing share inside 7500 Single Hung qualifies as Most Efficient?

EPA lists 8,400 Most Efficient options (19.9% share) inside JELD-WEN, inc. 7500 Single Hung, out of 42,169 total Version 7.0 entries.

### Do 2026 7500 Single Hung installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on 7500 Single Hung?

Confirm both the paper NFRC label and permanent corner glass etch match line JEL-A-1009 and NFRC ID JEL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. 7500 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)