---
title: "JELD-WEN Brickmould/Builders/Flat Casing Vinyl (V-2500)"
url: https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-brickmould-builders-flat-casing-vinyl-v-2500-double-hun/
description: "JELD-WEN Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung (JEL-A-725, Double Hung, Vinyl): U-Factor 0.25-0.32, SHGC 0.13-0.48, 1398 options across."
---

Window · Vinyl Frame NFRC JEL · Product Line JEL-A-725

# JELD-WEN, inc. — Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung · Double Hung

EPA ENERGY STAR Version 7.0 certifies 1,398 variants inside JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung, combining Vinyl frame construction with U-Factors spanning 0.25 to 0.32 and SHGC 0.13 to 0.48. Qualifying for Northern, North-Central, South-Central, Southern, this Double Hung family places #1,174 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.25

- **SHGC Range** : 0.13-0.48

- **Certified Options** : 1,398

- **Category Standing** : #1,174 of 1,352

## How does JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung compare thermally against Window peers?

JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung reaches 0.25 on its lowest-conductivity package — #907 of 1,009 in Vinyl, tied with 49 others at 0.25, more insulating than 5.3% of Vinyl lines (+0.06 vs Vinyl peers). Pairing NFRC ID JEL across multi-pane fills shifts U-Factor from 0.32 down toward 0.25.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 24 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 150.0 BTU/hr (+13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-10-11.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,398 certified glazing combinations for Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 24 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 24 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 182 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 1,374 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Silver Line Building Products** — 8601 Double Hung](https://ela-ecolandscapingassn.org/windows/models/silver-line-building-products-8601-double-hung-414093/) | Vinyl | 0.25 | 0.17 | 1,209 |
| [**Krestmark Industries L. P.** — 200/220/275 Single Hung](https://ela-ecolandscapingassn.org/windows/models/krestmark-industries-l-p-200-220-275-single-hung-413500/) | Vinyl | 0.25 | 0.11 | 1,065 |
| [**Amsco Windows** — VS1 (Studio) Single Hung](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vs1-studio-single-hung-412896/) | Vinyl | 0.25 | 0.13 | 1,038 |
| [**YKK AP America, Inc.** — Style View/Style View Classic Single Hung Archtop](https://ela-ecolandscapingassn.org/windows/models/ykk-ap-america-inc-style-view-style-view-classic-single-hung-archtop/) | Vinyl | 0.25 | 0.18 | 1,016 |
| [**YKK AP America, Inc.** — Style View/Style View NT/Precedence/Style View Classic Single Hung](https://ela-ecolandscapingassn.org/windows/models/ykk-ap-america-inc-style-view-style-view-nt-precedence-style-view-cl/) | Vinyl | 0.25 | 0.18 | 947 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung appear below.

### Where does JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung stand thermally among ENERGY STAR Window lines?

Testing puts JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung at rank #1,174 of 1,352 Window entries with U 0.25 to 0.32 across 1,398 configurations. Solar heat gain ranges between 0.13 and 0.48 across Northern, North-Central, South-Central, Southern.

### Can homeowners install Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung in cold Northern ENERGY STAR counties?

While JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung misses the <= 0.22 prescriptive mark (floor U 0.25), 24 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

### How do you calculate winter heat conduction for JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 150.0 BTU/hr on Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung's lowest-U package (0.25), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### What are the practical limitations of specifying Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung?

Skip Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung options exceeding U 0.22.

### Can you install JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 1,374 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung, while total line SHGC reaches 0.48 in colder packages.

### What glazing share inside Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung qualifies as Most Efficient?

No. Zero of the 1,398 configurations in JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### Can homeowners claim Form 5695 credits on JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung in 2026?

Any Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How can homeowners confirm delivered JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code JEL and product line JEL-A-725, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Brickmould/Builders/Flat Casing Vinyl (V-2500) Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
