---
title: "JELD-WEN Brickmould Vinyl (V-3700) Double Hung Fixed Specs"
url: https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-brickmould-vinyl-v-3700-double-hung-fixed-413355/
description: "JELD-WEN Brickmould Vinyl (V-3700) Double Hung Fixed (JEL-A-661, Picture Window, Vinyl): U-Factor 0.22-0.32, SHGC 0.14-0.54, 955 options across 4 ENERGY."
---

Window · Vinyl Frame NFRC JEL · Product Line JEL-A-661 ENERGY STAR Most Efficient Eligible

# JELD-WEN, inc. — Brickmould Vinyl (V-3700) Double Hung Fixed · Picture Window

JELD-WEN, inc. Brickmould Vinyl (V-3700) Double Hung Fixed is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.22 across 955 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #831 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.54.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.22

- **SHGC Range** : 0.14-0.54

- **Certified Options** : 955

- **Category Standing** : #831 of 1,352

## How does JELD-WEN, inc. Brickmould Vinyl (V-3700) Double Hung Fixed compare thermally against Window peers?

JELD-WEN, inc. Brickmould Vinyl (V-3700) Double Hung Fixed achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Brickmould Vinyl (V-3700) Double Hung Fixed spans 955 NFRC test records (JEL), ranking #831 of 1,352 Window families (tied with 104 others at 0.22, more insulating than 30.8% of Window lines). Its 0.22 thermal floor compares at +0.03 against the Vinyl median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 12 configurations meet ENERGY STAR Most Efficient criteria while 156 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.22 U-Factor yields 132.0 BTU/hr transfer (matching the 0.22 Northern baseline). Manufacturer filing reflects 2018-01-10 licensing and 2024-09-19 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 955 certified glazing combinations for Brickmould Vinyl (V-3700) Double Hung Fixed (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 156 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 196 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 414 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 759 packages (12 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**WeatherBarr Windows and Doors** — Cornerstone/Heritage Double Hung](https://ela-ecolandscapingassn.org/windows/models/weatherbarr-windows-and-doors-cornerstone-heritage-double-hung-41328/) | Vinyl | 0.22 | 0.16 | 865 |
| [**Earthwise Group, LLC** — 143.093,.095/343.293,.295/443.095,.293,.295/642.295/643.295/743.095,.295 SH](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-143-093-095-343-293-295-443-095-293-295-642-295/) | Vinyl | 0.22 | 0.13 | 842 |
| [**Earthwise Group, LLC** — 143.093/143.095/343.095/343.293/343.295/443.095/443.293/443.295/642.295/643.295 Single Slider](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-143-093-143-095-343-095-343-293-343-295-443-095/) | Vinyl | 0.22 | 0.13 | 834 |
| [**Associated Materials, Inc.** — 1904 Picture Window](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-1904-picture-window-413065/) | Vinyl | 0.22 | 0.09 | 1,123 |
| [**Associated Materials, Inc.** — 1914 Picture Window](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-1914-picture-window-413072/) | Vinyl | 0.22 | 0.09 | 1,203 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Brickmould Vinyl (V-3700) Double Hung Fixed appear below.

### Where does JELD-WEN, inc. Brickmould Vinyl (V-3700) Double Hung Fixed stand thermally among ENERGY STAR Window lines?

JELD-WEN, inc. Brickmould Vinyl (V-3700) Double Hung Fixed spans 955 certified configurations with U-Factors between 0.22 and 0.32 and SHGC values from 0.14 to 0.54. Ranked #831 of 1,352 Window families, it carries 12 Most Efficient options.

### How does JELD-WEN, inc. Brickmould Vinyl (V-3700) Double Hung Fixed satisfy Version 7.0 Northern criteria?

JELD-WEN, inc. Brickmould Vinyl (V-3700) Double Hung Fixed supplies 156 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

### How do you calculate winter heat conduction for JELD-WEN, inc. Brickmould Vinyl (V-3700) Double Hung Fixed?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.22 U-Factor yields 132.0 BTU/hr conductive transfer (+0.0% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Which situations make Brickmould Vinyl (V-3700) Double Hung Fixed the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Brickmould Vinyl (V-3700) Double Hung Fixed options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### What Southern ENERGY STAR v7.0 options exist in Brickmould Vinyl (V-3700) Double Hung Fixed?

Exactly 759 Brickmould Vinyl (V-3700) Double Hung Fixed options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.14 rather than higher 0.54 glass.

### Does Brickmould Vinyl (V-3700) Double Hung Fixed carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 12 of 955 Brickmould Vinyl (V-3700) Double Hung Fixed glazing builds earn Most Efficient recognition (1.3%), while other variants sit on the standard Version 7.0 tier.

### Can homeowners claim Form 5695 credits on JELD-WEN, inc. Brickmould Vinyl (V-3700) Double Hung Fixed in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 JELD-WEN, inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How can homeowners confirm delivered JELD-WEN, inc. Brickmould Vinyl (V-3700) Double Hung Fixed units match permits?

Verify NFRC ID JEL and series JEL-A-661 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Brickmould Vinyl (V-3700) Double Hung Fixed come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
