---
title: "JELD-WEN Brickmould Vinyl (V-3700) Fixed Specs (U 0.22)"
url: https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-brickmould-vinyl-v-3700-fixed-413351/
description: "JELD-WEN Brickmould Vinyl (V-3700) Fixed (JEL-A-541, Picture Window, Vinyl): U-Factor 0.22-0.32, SHGC 0.14-0.53, 1092 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC JEL · Product Line JEL-A-541 ENERGY STAR Most Efficient Eligible

# JELD-WEN, inc. — Brickmould Vinyl (V-3700) Fixed · Picture Window

JELD-WEN, inc. engineered the Brickmould Vinyl (V-3700) Fixed Picture Window line for Northern, North-Central, South-Central, Southern, certifying 1,092 glass-spacer combinations from 0.22 to 0.32 U-Factor and 0.14 to 0.53 SHGC. Relative to other Vinyl models tracked under NFRC JEL, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.22

- **SHGC Range** : 0.14-0.53

- **Certified Options** : 1,092

- **Category Standing** : #831 of 1,352

## How does JELD-WEN, inc. Brickmould Vinyl (V-3700) Fixed compare thermally against Window peers?

JELD-WEN, inc. Brickmould Vinyl (V-3700) Fixed achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows JELD-WEN, inc. Brickmould Vinyl (V-3700) Fixed standing at #831 of 1,352 certified Window product series, tied with 104 others at 0.22, more insulating than 30.8% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.03 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. 12 configurations meet ENERGY STAR Most Efficient criteria while 160 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-09-19 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 132.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,092 certified glazing combinations for Brickmould Vinyl (V-3700) Fixed (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 160 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 200 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 472 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 890 packages (12 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Associated Materials, Inc.** — 1904 Picture Window](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-1904-picture-window-413065/) | Vinyl | 0.22 | 0.09 | 1,123 |
| [**Associated Materials, Inc.** — 1914 Picture Window](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-1914-picture-window-413072/) | Vinyl | 0.22 | 0.09 | 1,203 |
| [**Associated Materials, Inc.** — 1704 Picture Window](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-1704-picture-window-413068/) | Vinyl | 0.22 | 0.17 | 1,211 |
| [**EnergyWall Window** — 3000/1500 Picture Window](https://ela-ecolandscapingassn.org/windows/models/energywall-window-3000-1500-picture-window-413223/) | Vinyl | 0.22 | 0.20 | 1,214 |
| [**Polaris Windows and Doors** — 3000/1500 Picture Window](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-3000-1500-picture-window-413930/) | Vinyl | 0.22 | 0.20 | 1,214 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Brickmould Vinyl (V-3700) Fixed appear below.

### How well does Brickmould Vinyl (V-3700) Fixed by JELD-WEN, inc. insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 1,092 configurations for JELD-WEN, inc. Brickmould Vinyl (V-3700) Fixed covering Northern, North-Central, South-Central, Southern, dropping down to U 0.22 versus a 0.20 Window median. Only 12 options earn Most Efficient status.

### Is Brickmould Vinyl (V-3700) Fixed approved for Northern Zone heating climates?

Yes. 160 packages in JELD-WEN, inc. Brickmould Vinyl (V-3700) Fixed clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

### How do you calculate winter heat conduction for JELD-WEN, inc. Brickmould Vinyl (V-3700) Fixed?

At U 0.22, a standard 3x5 ft (15 sq ft) Brickmould Vinyl (V-3700) Fixed opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.

### Who should NOT choose JELD-WEN, inc. Brickmould Vinyl (V-3700) Fixed for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Brickmould Vinyl (V-3700) Fixed options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Does Brickmould Vinyl (V-3700) Fixed meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Brickmould Vinyl (V-3700) Fixed holds 890 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.

### Does Brickmould Vinyl (V-3700) Fixed carry EPA Most Efficient certification across its lineup?

No. Exactly 12 of 1,092 configurations (1.1%) earn ENERGY STAR Most Efficient status in Brickmould Vinyl (V-3700) Fixed; the remaining standard v7.0 options pass base zone limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Brickmould Vinyl (V-3700) Fixed?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Brickmould Vinyl (V-3700) Fixed installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### Where are NFRC and IGCC identification marks located on Brickmould Vinyl (V-3700) Fixed?

Inspectors match the temporary NFRC sticker (U 0.22-0.32, SHGC 0.14-0.53) against permit drawings for line JEL-A-541. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Brickmould Vinyl (V-3700) Fixed come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
