---
title: "JELD-WEN Brickmould Vinyl (V-3700) Tilt Single Hung Specs"
url: https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-brickmould-vinyl-v-3700-tilt-single-hung-413350/
description: "JELD-WEN Brickmould Vinyl (V-3700) Tilt Single Hung (JEL-A-540, Single Hung, Vinyl): U-Factor 0.25-0.32, SHGC 0.13-0.49, 1310 options across 4 ENERGY STAR."
---

Window · Vinyl Frame NFRC JEL · Product Line JEL-A-540

# JELD-WEN, inc. — Brickmould Vinyl (V-3700) Tilt Single Hung · Single Hung

Positioning #1,174/1,352 in certified Window, JELD-WEN, inc. Brickmould Vinyl (V-3700) Tilt Single Hung pairs Vinyl frame construction with 1,310 glazing options rated between 0.13 and 0.49 SHGC across Northern, North-Central, South-Central, Southern. Across 61 certified JELD-WEN, inc. product families, its thermal resistance spans 0.25 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.25

- **SHGC Range** : 0.13-0.49

- **Certified Options** : 1,310

- **Category Standing** : #1,174 of 1,352

## How does JELD-WEN, inc. Brickmould Vinyl (V-3700) Tilt Single Hung compare thermally against Window peers?

JELD-WEN, inc. Brickmould Vinyl (V-3700) Tilt Single Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Brickmould Vinyl (V-3700) Tilt Single Hung spans 1,310 NFRC test records (JEL), ranking #1,174 of 1,352 Window families (tied with 81 others at 0.25, more insulating than 7.2% of Window lines). Its 0.25 thermal floor compares at +0.06 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.13 to 0.49) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 26 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-09-19 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,310 certified glazing combinations for Brickmould Vinyl (V-3700) Tilt Single Hung (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 26 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 42 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 186 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 1,268 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Silver Line Building Products** — 8601 Double Hung](https://ela-ecolandscapingassn.org/windows/models/silver-line-building-products-8601-double-hung-414093/) | Vinyl | 0.25 | 0.17 | 1,209 |
| [**Krestmark Industries L. P.** — 200/220/275 Single Hung](https://ela-ecolandscapingassn.org/windows/models/krestmark-industries-l-p-200-220-275-single-hung-413500/) | Vinyl | 0.25 | 0.11 | 1,065 |
| [**Amsco Windows** — VS1 (Studio) Single Hung](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vs1-studio-single-hung-412896/) | Vinyl | 0.25 | 0.13 | 1,038 |
| [**YKK AP America, Inc.** — Style View/Style View Classic Single Hung Archtop](https://ela-ecolandscapingassn.org/windows/models/ykk-ap-america-inc-style-view-style-view-classic-single-hung-archtop/) | Vinyl | 0.25 | 0.18 | 1,016 |
| [**YKK AP America, Inc.** — Style View/Style View NT/Precedence/Style View Classic Single Hung](https://ela-ecolandscapingassn.org/windows/models/ykk-ap-america-inc-style-view-style-view-nt-precedence-style-view-cl/) | Vinyl | 0.25 | 0.18 | 947 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Brickmould Vinyl (V-3700) Tilt Single Hung appear below.

### What U-Factor and SHGC range does JELD-WEN, inc. Brickmould Vinyl (V-3700) Tilt Single Hung achieve?

Built with Vinyl framing in Single-Hung (VSSH) style, JELD-WEN, inc. Brickmould Vinyl (V-3700) Tilt Single Hung offers 1,310 Version 7.0 configurations from U 0.25 up to 0.32, posting +0.05 against the Window median of 0.20 with 0 Most Efficient picks.

### Can homeowners install Brickmould Vinyl (V-3700) Tilt Single Hung in cold Northern ENERGY STAR counties?

Prescriptive Northern approval ends at U <= 0.22, above Brickmould Vinyl (V-3700) Tilt Single Hung's 0.25 minimum. However, 26 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

### How much winter heat loss does Brickmould Vinyl (V-3700) Tilt Single Hung conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.25 U-Factor yields 150.0 BTU/hr conductive transfer (+13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What are the practical limitations of specifying Brickmould Vinyl (V-3700) Tilt Single Hung?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Brickmould Vinyl (V-3700) Tilt Single Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### What Southern ENERGY STAR v7.0 options exist in Brickmould Vinyl (V-3700) Tilt Single Hung?

Yes, Brickmould Vinyl (V-3700) Tilt Single Hung holds 1,268 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

### What glazing share inside Brickmould Vinyl (V-3700) Tilt Single Hung qualifies as Most Efficient?

All 1,310 Brickmould Vinyl (V-3700) Tilt Single Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### Do 2026 Brickmould Vinyl (V-3700) Tilt Single Hung installations qualify for IRS Section 25C tax credits?

Any Brickmould Vinyl (V-3700) Tilt Single Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do you cross-check NFRC JEL and product line JEL-A-540 on delivery?

Verify NFRC ID JEL and series JEL-A-540 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Brickmould Vinyl (V-3700) Tilt Single Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
