Window · Wood Frame NFRC JEL · Product Line JEL-N-791

# JELD-WEN, inc. — Custom Clad Epic Double Hung Picture · Picture Window

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—JELD-WEN, inc. Custom Clad Epic Double Hung Picture spans 755 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code JEL, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.10 and 0.41.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.10-0.41

- **Certified Options** : 755

- **Category Standing** : #1,034 of 1,352

## How does JELD-WEN, inc. Custom Clad Epic Double Hung Picture compare thermally against Window peers?

JELD-WEN, inc. Custom Clad Epic Double Hung Picture achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Custom Clad Epic Double Hung Picture spans 755 NFRC test records (JEL), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.03 against the Wood median (0.21).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 3 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors JEL to 2024-02-28 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 755 certified glazing combinations for Custom Clad Epic Double Hung Picture (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 3 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 17 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 90 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 746 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Windsor Windows and Doors** — Revive Clad Pocket Awning](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-revive-clad-pocket-awning-414450/) | Wood | 0.24 | 0.15 | 782 |
| [**Windsor Windows and Doors** — Revive Clad Pocket Casement](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-revive-clad-pocket-casement-414446/) | Wood | 0.24 | 0.15 | 805 |
| [**Windsor Windows and Doors** — Revive Hybrid Pocket Double Hung Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-revive-hybrid-pocket-double-hung-picture-4/) | Wood | 0.24 | 0.11 | 545 |
| [**Andersen Corporation** — E-Series Fixed Casement Window - Direct-Set (1 Piece)](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-fixed-casement-window-direct-set-1-pie/) | Wood | 0.24 | 0.08 | 494 |
| [**Windsor Windows and Doors** — Revive Legend Win-Pac](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-revive-legend-win-pac-414428/) | Wood | 0.24 | 0.11 | 494 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Custom Clad Epic Double Hung Picture appear below.

### What thermal performance numbers separate JELD-WEN, inc. Custom Clad Epic Double Hung Picture from peers?

Across 755 tested NFRC glazing configurations, JELD-WEN, inc. Custom Clad Epic Double Hung Picture with Wood framing and Fixed Window (FIXD) style reaches a 0.24 minimum U-Factor and 0.10-0.41 SHGC band. It places #1,034 among 1,352 Window series—more insulating than 13.2%.

### Which glazing options in JELD-WEN, inc. Custom Clad Epic Double Hung Picture meet Northern climate limits?

Northern qualification on Custom Clad Epic Double Hung Picture relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 3 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

### What BTU/hr heat transfer results from Custom Clad Epic Double Hung Picture's 0.24 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Custom Clad Epic Double Hung Picture at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Who should NOT choose JELD-WEN, inc. Custom Clad Epic Double Hung Picture for a residential project?

Skip Custom Clad Epic Double Hung Picture if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Custom Clad Epic Double Hung Picture options exceeding U 0.22.

### What Southern ENERGY STAR v7.0 options exist in Custom Clad Epic Double Hung Picture?

Warm-climate homeowners have 746 Southern-approved options within Custom Clad Epic Double Hung Picture spanning SHGC down to 0.10. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Does Custom Clad Epic Double Hung Picture carry EPA Most Efficient certification across its lineup?

No. Zero of the 755 configurations in JELD-WEN, inc. Custom Clad Epic Double Hung Picture hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Custom Clad Epic Double Hung Picture?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How can homeowners confirm delivered JELD-WEN, inc. Custom Clad Epic Double Hung Picture units match permits?

Inspectors match the temporary NFRC sticker (U 0.24-0.32, SHGC 0.10-0.41) against permit drawings for line JEL-N-791. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Custom Clad Epic Double Hung Picture come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)