title: "JELD-WEN Custom EpicVue Clad Radius Pushout Casement Specs"
url: https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-custom-epicvue-clad-radius-pushout-casement-413369/
description: "JELD-WEN Custom EpicVue Clad Radius Pushout Casement (JEL-N-743, Casement Windows, Wood): U-Factor 0.25-0.32, SHGC 0.11-0.38, 501 options across 3 ENERGY."
---

Window · Wood Frame NFRC JEL · Product Line JEL-N-743

# JELD-WEN, inc. — Custom EpicVue Clad Radius Pushout Casement · Casement Windows

JELD-WEN, inc. engineered the Custom EpicVue Clad Radius Pushout Casement Casement Windows line for North-Central, South-Central, Southern, certifying 501 glass-spacer combinations from 0.25 to 0.32 U-Factor and 0.11 to 0.38 SHGC. Relative to other Wood models tracked under NFRC JEL, its minimum U-Factor is 0.04 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.25

- **SHGC Range** : 0.11-0.38

- **Certified Options** : 501

- **Category Standing** : #1,174 of 1,352

## How does JELD-WEN, inc. Custom EpicVue Clad Radius Pushout Casement compare thermally against Window peers?

JELD-WEN, inc. Custom EpicVue Clad Radius Pushout Casement achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places JELD-WEN, inc. Custom EpicVue Clad Radius Pushout Casement at rank #1,174 of 1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.11-0.38 band.

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Lifecycle documentation anchors JEL to 2026-06-08 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 150.0 BTU/hr conductive loss (+13.6% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 501 certified glazing combinations for Custom EpicVue Clad Radius Pushout Casement (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 15 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 31 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 495 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Windsor Windows and Doors** — Revive Hybrid Pocket Double Hung](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-revive-hybrid-pocket-double-hung-414438/) | Wood | 0.25 | 0.11 | 450 |
| [**Windsor Windows and Doors** — Revive Primed Win-Pac](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-revive-primed-win-pac-414427/) | Wood | 0.25 | 0.11 | 423 |
| [**Windsor Windows and Doors** — Legend HBR Double Hung](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-legend-hbr-double-hung-414429/) | Wood | 0.25 | 0.11 | 412 |
| [**Windsor Windows and Doors** — Pinnacle Clad Casement](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-casement-414390/) | Wood | 0.25 | 0.15 | 385 |
| [**Andersen Corporation** — 200 Series Tilt-Wash Double Hung Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-tilt-wash-double-hung-window-412925/) | Wood | 0.25 | 0.14 | 381 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Custom EpicVue Clad Radius Pushout Casement appear below.

### How well does Custom EpicVue Clad Radius Pushout Casement by JELD-WEN, inc. insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 501 configurations for JELD-WEN, inc. Custom EpicVue Clad Radius Pushout Casement covering North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Which glazing options in JELD-WEN, inc. Custom EpicVue Clad Radius Pushout Casement meet Northern climate limits?

No. Because Custom EpicVue Clad Radius Pushout Casement reaches only 0.25 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Wood line strictly across North-Central, South-Central, Southern cooling or mixed markets.

### What BTU/hr heat transfer results from Custom EpicVue Clad Radius Pushout Casement's 0.25 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Custom EpicVue Clad Radius Pushout Casement at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What homeowner profiles are a poor match for JELD-WEN, inc. Custom EpicVue Clad Radius Pushout Casement?

Do not specify Custom EpicVue Clad Radius Pushout Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Custom EpicVue Clad Radius Pushout Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in Custom EpicVue Clad Radius Pushout Casement?

Across North-Central, South-Central, Southern, 495 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside JELD-WEN, inc. Custom EpicVue Clad Radius Pushout Casement, while total line SHGC reaches 0.38 in colder packages.

### How many JELD-WEN, inc. Custom EpicVue Clad Radius Pushout Casement variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 501 Custom EpicVue Clad Radius Pushout Casement options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### What federal compliance checks govern 2026 Custom EpicVue Clad Radius Pushout Casement window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Custom EpicVue Clad Radius Pushout Casement retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How can homeowners confirm delivered JELD-WEN, inc. Custom EpicVue Clad Radius Pushout Casement units match permits?

Verify NFRC ID JEL and series JEL-N-743 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Custom EpicVue Clad Radius Pushout Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)