title: "JELD-WEN Premium Atlantic Vinyl Casement Specs (U 0.23)"
url: https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-atlantic-vinyl-casement-413362/
description: "JELD-WEN Premium Atlantic Vinyl Casement (JEL-A-685, Casement Windows, Vinyl): U-Factor 0.23-0.32, SHGC 0.12-0.25, 889 options across 3 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC JEL · Product Line JEL-A-685

# JELD-WEN, inc. — Premium Atlantic Vinyl Casement · Casement Windows

JELD-WEN, inc. Premium Atlantic Vinyl Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.23 across 889 certified glazing configurations covering North-Central, South-Central, Southern. Ranked #936 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.25.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.12-0.25

- **Certified Options** : 889

- **Category Standing** : #936 of 1,352

## How does JELD-WEN, inc. Premium Atlantic Vinyl Casement compare thermally against Window peers?

JELD-WEN, inc. Premium Atlantic Vinyl Casement achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), Premium Atlantic Vinyl Casement reaches 0.23 on its lowest-conductivity package — #716 of 1,009 in Vinyl, tied with 81 others at 0.23, more insulating than 21.0% of Vinyl lines (+0.04 vs Vinyl peers). Pairing NFRC ID JEL across multi-pane fills shifts U-Factor from 0.32 down toward 0.23.

Mapping NFRC SHGC values (0.12 to 0.25) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Data provenance links certification 2024-11-25 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 889 certified glazing combinations for Premium Atlantic Vinyl Casement (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 58 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 340 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 881 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Atrium Companies, Inc.** — 316 Sidelite](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-316-sidelite-412875/) | Vinyl | 0.23 | 0.16 | 905 |
| [**Associated Materials, Inc.** — 1702 Single Slider](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-1702-single-slider-413069/) | Vinyl | 0.23 | 0.17 | 1,088 |
| [**Krestmark Industries L. P.** — 200/220/275 Picture Window](https://ela-ecolandscapingassn.org/windows/models/krestmark-industries-l-p-200-220-275-picture-window-413502/) | Vinyl | 0.23 | 0.12 | 1,123 |
| [**MGM Industries** — 6010/6060 Single Hung](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-6060-single-hung-413724/) | Vinyl | 0.23 | 0.13 | 641 |
| [**Earthwise Group, LLC** — 143.095,.195/145.095,.195/144.195/343.095/443.095,.295/643.095,.195/642.295/743.095,.295 DH](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-143-095-195-145-095-195-144-195-343-095-443-095/) | Vinyl | 0.23 | 0.13 | 562 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Premium Atlantic Vinyl Casement appear below.

### What U-Factor and SHGC range does JELD-WEN, inc. Premium Atlantic Vinyl Casement achieve?

Testing puts JELD-WEN, inc. Premium Atlantic Vinyl Casement at rank #936 of 1,352 Window entries with U 0.23 to 0.32 across 889 configurations. Solar heat gain ranges between 0.12 and 0.25 across North-Central, South-Central, Southern.

### Is Premium Atlantic Vinyl Casement approved for Northern Zone heating climates?

No. Because Premium Atlantic Vinyl Casement reaches only 0.23 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Vinyl line strictly across North-Central, South-Central, Southern cooling or mixed markets.

### How much winter heat loss does Premium Atlantic Vinyl Casement conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Premium Atlantic Vinyl Casement at U 0.23 conducts 138.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Who should NOT choose JELD-WEN, inc. Premium Atlantic Vinyl Casement for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Premium Atlantic Vinyl Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Is Premium Atlantic Vinyl Casement suitable for sunbelt cooling-dominated homes?

Yes. 881 Southern-certified options inside JELD-WEN, inc. Premium Atlantic Vinyl Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.25 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Are all 889 Premium Atlantic Vinyl Casement configurations ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 889 Premium Atlantic Vinyl Casement options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### Can homeowners claim Form 5695 credits on JELD-WEN, inc. Premium Atlantic Vinyl Casement in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### What permanent glass etch marks verify Premium Atlantic Vinyl Casement after sticker removal?

Match the NFRC thermal sticker for code JEL and line JEL-A-685 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Premium Atlantic Vinyl Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)