---
title: "JELD-WEN Premium Vinyl (V-4500) Sliding Patio Door Specs"
url: https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-sliding-patio-door-413363/
description: "JELD-WEN Premium Vinyl (V-4500) Sliding Patio Door (JEL-A-697, Sliding Patio Door, Vinyl): U-Factor 0.19-0.28, SHGC 0.15-0.39, 2676 options across 4 ENERGY."
---

Door · Vinyl Frame NFRC JEL · Product Line JEL-A-697 ENERGY STAR Most Efficient Eligible

# JELD-WEN, inc. — Premium Vinyl (V-4500) Sliding Patio Door · Sliding Patio Door

Positioning #94/268 in certified Door, JELD-WEN, inc. Premium Vinyl (V-4500) Sliding Patio Door pairs Vinyl frame construction with 2,676 glazing options rated between 0.15 and 0.39 SHGC across Northern, North-Central, South-Central, Southern. Across 61 certified JELD-WEN, inc. product families, its thermal resistance spans 0.19 to 0.28 U-Factor and the line includes 21 ENERGY STAR Most Efficient packages (0.8% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.19

- **SHGC Range** : 0.15-0.39

- **Certified Options** : 2,676

- **Category Standing** : #94 of 268

## How does JELD-WEN, inc. Premium Vinyl (V-4500) Sliding Patio Door compare thermally against Door peers?

JELD-WEN, inc. Premium Vinyl (V-4500) Sliding Patio Door achieves a 0.19 thermal floor across Door lines, placing #94 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), Premium Vinyl (V-4500) Sliding Patio Door is 0.02 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.19-0.28.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 21 configurations meet ENERGY STAR Most Efficient criteria while 1,208 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-10-11 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 114.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,676 certified glazing combinations for Premium Vinyl (V-4500) Sliding Patio Door (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 1,208 packages (6 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,208 packages (12 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 2,189 packages (9 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,189 packages (18 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Sierra Pacific Windows** — Vinyl Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-vinyl-sliding-glass-door-414075/) | Vinyl | 0.19 | 0.11 | 1,547 |
| [**DRUTEX S.A.** — IGLO 5 Outswing Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-outswing-door-413158/) | Vinyl | 0.19 | 0.12 | 1,474 |
| [**Great Day Improvements, LLC** — 3100+ Patio Door](https://ela-ecolandscapingassn.org/windows/models/great-day-improvements-llc-3100-patio-door-413108/) | Vinyl | 0.19 | 0.17 | 1,351 |
| [**Wincore Window Company, LLC** — 5400 5400S 7700 9900 Series Vinyl Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-5400s-7700-9900-series-vinyl-sliding/) | Vinyl | 0.19 | 0.07 | 4,158 |
| [**Vinylmax LLC** — PD19 Patio Door (Exterior Glazed)](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-pd19-patio-door-exterior-glazed-414259/) | Vinyl | 0.19 | 0.13 | 662 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Premium Vinyl (V-4500) Sliding Patio Door appear below.

### How well does Premium Vinyl (V-4500) Sliding Patio Door by JELD-WEN, inc. insulate relative to Door benchmarks?

Testing puts JELD-WEN, inc. Premium Vinyl (V-4500) Sliding Patio Door at rank #94 of 268 Door entries with U 0.19 to 0.28 across 2,676 configurations. Solar heat gain ranges between 0.15 and 0.39 across Northern, North-Central, South-Central, Southern.

### Is Premium Vinyl (V-4500) Sliding Patio Door approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 1,208 Premium Vinyl (V-4500) Sliding Patio Door packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

### What conductive BTU/hr difference separates Premium Vinyl (V-4500) Sliding Patio Door from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What are the practical limitations of specifying Premium Vinyl (V-4500) Sliding Patio Door?

Do not specify Premium Vinyl (V-4500) Sliding Patio Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Premium Vinyl (V-4500) Sliding Patio Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Is Premium Vinyl (V-4500) Sliding Patio Door suitable for sunbelt cooling-dominated homes?

Yes. 2,189 Southern-certified options inside JELD-WEN, inc. Premium Vinyl (V-4500) Sliding Patio Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.39 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Which package tier in Premium Vinyl (V-4500) Sliding Patio Door holds Most Efficient recognition?

EPA lists 21 Most Efficient options (0.8% share) inside JELD-WEN, inc. Premium Vinyl (V-4500) Sliding Patio Door, out of 2,676 total Version 7.0 entries.

### What 2026 federal tax credit and Lead RRP rules apply to Premium Vinyl (V-4500) Sliding Patio Door?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Premium Vinyl (V-4500) Sliding Patio Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### What permanent glass etch marks verify Premium Vinyl (V-4500) Sliding Patio Door after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code JEL and product line JEL-A-697, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Premium Vinyl (V-4500) Sliding Patio Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
