title: "JELD-WEN Premium Vinyl (V-4500) Tilt Single Hung Specs"
url: https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-tilt-single-hung-413385/
description: "JELD-WEN Premium Vinyl (V-4500) Tilt Single Hung (JEL-A-898, Single Hung, Vinyl): U-Factor 0.18-0.32, SHGC 0.12-0.51, 11430 options across 4 ENERGY STAR."
---

Window · Vinyl Frame NFRC JEL · Product Line JEL-A-898 ENERGY STAR Most Efficient Eligible

# JELD-WEN, inc. — Premium Vinyl (V-4500) Tilt Single Hung · Single Hung

Positioning #477/1,352 in certified Window, JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung pairs Vinyl frame construction with 11,430 glazing options rated between 0.12 and 0.51 SHGC across Northern, North-Central, South-Central, Southern. Across 61 certified JELD-WEN, inc. product families, its thermal resistance spans 0.18 to 0.32 U-Factor and the line includes 97 ENERGY STAR Most Efficient packages (0.8% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.18

- **SHGC Range** : 0.12-0.51

- **Certified Options** : 11,430

- **Category Standing** : #477 of 1,352

## How does JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung compare thermally against Window peers?

JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 61 certified JELD-WEN, inc. series, this Single Hung offers a 0.14 U-Factor adjustment span between 0.32 entry options and 0.18 top-performing glazing. Category standing is #477/1,352 (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%).

Mapping NFRC SHGC values (0.12 to 0.51) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 97 configurations meet ENERGY STAR Most Efficient criteria while 536 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.18 U-Factor yields 108.0 BTU/hr transfer (-24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-02-28 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 11,430 certified glazing combinations for Premium Vinyl (V-4500) Tilt Single Hung (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 536 packages (47 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,281 packages (81 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 3,496 packages (60 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 10,490 packages (76 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Milgard Manufacturing, Inc.** — 8220/8230/8270 Single Hung](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8220-8230-8270-single-hung-413738/) | Vinyl | 0.18 | 0.09 | 9,233 |
| [**Milgard Manufacturing, Inc.** — 8140 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8140-horizontal-slider-413751/) | Vinyl | 0.18 | 0.09 | 9,072 |
| [**Milgard Manufacturing, Inc.** — 8120/8130/8170 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8120-8130-8170-horizontal-slider-413737/) | Vinyl | 0.18 | 0.09 | 9,007 |
| [**Milgard Manufacturing, Inc.** — 8240 Single Hung](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8240-single-hung-413752/) | Vinyl | 0.18 | 0.09 | 8,937 |
| [**PGT Industries** — DH5460/5560](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-dh5460-5560-413920/) | Vinyl | 0.18 | 0.08 | 6,757 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung appear below.

### What U-Factor and SHGC range does JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung achieve?

Testing puts JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung at rank #477 of 1,352 Window entries with U 0.18 to 0.32 across 11,430 configurations. Solar heat gain ranges between 0.12 and 0.51 across Northern, North-Central, South-Central, Southern.

### Can homeowners install Premium Vinyl (V-4500) Tilt Single Hung in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 536 Premium Vinyl (V-4500) Tilt Single Hung packages (U floor 0.18, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### What BTU/hr heat transfer results from Premium Vinyl (V-4500) Tilt Single Hung's 0.18 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 108.0 BTU/hr on Premium Vinyl (V-4500) Tilt Single Hung's lowest-U package (0.18), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### Who should NOT choose JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Premium Vinyl (V-4500) Tilt Single Hung options exceeding U 0.22. Additionally, do not order Single-Hung (VSSH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### How many Premium Vinyl (V-4500) Tilt Single Hung glazing packages pass Southern solar-heat rules?

Yes, Premium Vinyl (V-4500) Tilt Single Hung holds 10,490 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.12 SHGC in cooling climates.

### What glazing share inside Premium Vinyl (V-4500) Tilt Single Hung qualifies as Most Efficient?

No. Exactly 97 of 11,430 configurations (0.8%) earn ENERGY STAR Most Efficient status in Premium Vinyl (V-4500) Tilt Single Hung; the remaining standard v7.0 options pass base zone limits only.

### Do 2026 Premium Vinyl (V-4500) Tilt Single Hung installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Premium Vinyl (V-4500) Tilt Single Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How can homeowners confirm delivered JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung units match permits?

Inspectors match the temporary NFRC sticker (U 0.18-0.32, SHGC 0.12-0.51) against permit drawings for line JEL-A-898. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)